2018 GRAND AVE B & A 2023 Plans 2025-09-11
>
Address Records
>
GRAND AVE
>
2018
>
Plans
>
2018 GRAND AVE B & A 2023 Plans 2025-09-11
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/11/2025 11:55:08 AM
Creation date
9/11/2025 11:53:56 AM
Metadata
Fields
Template:
Address Document
Street Name
GRAND AVE
Street Number
2018
Unit
B & A
Permit
B2306-063
Year
2023
Notes
24 SQ FT DORMER 2ND FLOOR AND BASEMENT ADU
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DREAMERS BUILDING LLC <br /> 509 93RD ST SW <br /> B2307-066 <br /> In order for the processing of your application to continue, the following documentation shall be <br /> submitted to Permit Services for review: <br /> a. Itemized letter addressing the comments provided below. <br /> b. Two complete sets of revised construction drawings. <br /> c. Two copies of supplemental structural calculations (if applicable). <br /> Submittal documents should contain sufficient information and detail to review the proposed project <br /> for compliance with the adopted building codes. Upon submittal of the revised documents, your <br /> application will be given priority and the review will recommence. <br /> Architectural (Reviewer: Yin Lu) <br /> 1. The drawing shall clearly show existing vs new work. Please revise accordingly. All <br /> unpermitted work shall be drawn as new work. <br /> 2. Min. ceiling height for Garage is 6'-8", however, per IRC 305.1, minimum ceiling height for <br /> habitable space is 7'. Please provide dormer ceiling height and the basement ceiling height. <br /> 3. You shall dimension the location and the size of new skylights, as well as framing design <br /> intent and U factor which shall be 0.5 max. Please provide information accordingly. <br /> 4. Per IRC 308.4, basement entry door is in hazard location, it shall be safety glazing. Please <br /> also double check the window per IRC 308.4.2 and dimension the window location. <br /> 5. Emergency escape and rescue opening is required per IRC 310.1. Please provide <br /> information accordingly, including be not limited to operable part size, AFF and etc.. <br /> 6. Please show smoke alarm per IRC 314.2.2 and carbon monoxide alarm per IRC 315.2. <br /> 7. Please show vent in bathroom per IRC M1505.4.4. Also, please provide existing whole house <br /> ventilation information per IRC M 1505.4.3. Please note if the whole house ventilation is <br /> cont. vs. intermitted, what is the CFM, and locate it on the floor plan. <br /> 8. Please provide information regarding the new gas fireplaces (two of them), is there any <br /> clearance requirement? Where the vent will go? Etc. <br /> 9. Electric panel needs clearance, please note on the floor plan accordingly. <br /> 10. Water heater shall have seismic restraint, please note on the floor plan. <br /> 11. New dormer roof is vented roof, please provide calculation per IRC 806.2. <br /> 12. Per WSEC, when converting a non-habitable space into a habitable space, insulation will be <br /> required to meet Table 402.6. Slab insulation shall be R-10 (2ft). You can provide <br /> calculation per WSEC R402.1.3 to alternate slab insulation to wall if that is the design intent. <br /> Please update your drawing and notes accordingly. <br /> 13. Dormer exterior wall also need to meet WSEC insulation requirement. <br /> IOU 3200 Cedar Street © 425.257.8810 0@ permitservices@everettwa.gov <br /> Everett,WA 98201 425.257.8857 fax everettwa.gov/permits <br /> Page 2 of 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.