My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1815 HOLBROOK AVE 2024 Plans 2025-09-11
>
Address Records
>
HOLBROOK AVE
>
1815
>
Plans
>
1815 HOLBROOK AVE 2024 Plans 2025-09-11
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/11/2025 2:35:41 PM
Creation date
9/11/2025 2:34:54 PM
Metadata
Fields
Template:
Address Document
Street Name
HOLBROOK AVE
Street Number
1815
Permit
B2410-063
Year
2024
Notes
Hot tub placement
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
4
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
*A1 <br /> Smith-Emery Laboratories <br /> An Independent Commercial Testing Laboratory,Established 1904 <br /> 781 East Washington Boulevard,Los Angeles, California 90021 ♦Phone(213) 745-5333 Fax(213) 741-8626 <br /> Project No.: 40463-1 November 21, 2011 <br /> Lab. No. : T-11-2041 <br /> CLIENT: Roberts Hot Tubs Inc. <br /> 2343 Welcome Ave. <br /> Richmond, CA 94804 <br /> Attn.: Robert Ghelerter <br /> SUBJECT: Mechanical Testing on Spas and Hot Tubs Covers <br /> SPECIFICATION: ASTM F1346 -91 Standard Performance Specification for Safety Covers and Labeling Requirements <br /> for All Covers for Swimming Pools, Spas and Hot Tubs <br /> SOURCE: Submitted to Laboratory by Client. <br /> Report of Tests <br /> Material Identification: <br /> Cover#1: Serial No.: 123621 <br /> Cover#2: Serial No.: 123622 <br /> Cover#3: Serial No.: 123623 <br /> Test No.1: STATIC LOAD TEST <br /> Load of 275 pounds was placed on top of an installed spa cover for 5 minutes. <br /> Cover#1: Shows no damage after loading on center and at mid point attachment center. <br /> Cover#2: Shows no damage after loading on center and at mid point attachment center. <br /> Cover#3: Shows no damage after loading on center and at mid point attachment center. <br /> Test No.2: PERIMETER DEFLECTION TEST <br /> Load of 50 pounds was placed on top of an installed spa cover 4 ft. from the side of the pool; then a <br /> "Perimeter Deflection Test Object" (3.7-inch by 5.7-inch by 12-inch length elipsoidal shape object at 36.6 <br /> lbs.) was placed at closed opennings and joints for observations. <br /> Cover#1: Perimeter Deflection Test Object did not pass through. <br /> Cover#2: Perimeter Deflection Test Object did not pass through. <br /> Cover#3: Perimeter Deflection Test Object did not pass through. <br /> Test No.3: SURFACE DRAINAGE TEST(Not Applicable-No Equipment to be operated) <br /> Test NoA: OPENINGS TEST <br /> A load of 40 pounds was applied to a solid faced sphere with a maximum diameter of 4.5-inches on any <br /> openings to observe if it will pass through. <br /> Cover#1: Opening Test Object did not pass through. <br /> Cover#2: Opening Test Object did not pass through. <br /> Cover#3: Opening Test Object did not pass through. <br /> Respectfully Submitted, ❑Materials Tested Comply With Specifications. <br /> SMITH-EMERY LABORATORIES ❑Materials Tested Did Not Comply With Specifications. <br /> ❑No Established Criteria for Acceptable Limits. <br /> 11 For Information Only <br />
The URL can be used to link to this page
Your browser does not support the video tag.