My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2326 MCDOUGALL AVE 2023 Plans 2025-09-12
>
Address Records
>
MCDOUGALL AVE
>
2326
>
Plans
>
2326 MCDOUGALL AVE 2023 Plans 2025-09-12
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/12/2025 8:31:30 AM
Creation date
9/12/2025 8:31:21 AM
Metadata
Fields
Template:
Address Document
Street Name
MCDOUGALL AVE
Street Number
2326
Permit
B2302-015
Year
2023
Notes
REMODEL 900SF OF BASEMENT ADD WALLS /WINDOWS
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
3
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ENERGY NOTES WALL LEGEND FLOOR PLAN NOTES ELECTRICAL LEGEND <br /> ENERGY CODE COMPLIANCE SHALL BE AS PER THE WASHINGTON STATE ENERGY 1.ALL DIMENSIONS ARE FROM FACE-OF-STUD TO FACE-OFSTUD,AND FACE-OF-BLOCK 110 V.ARC FAULT CIRCUIT J JUNCTION BOX CEILING MOUNTED 1'x 4' <br /> CODE 2018.MINIMUM INSULATION(R)VALUES OR U-VALUES OF COMPONENTS SHALL ___ DEMOLISHED U.N.O. TO FACE-OF-BLOCK(U.N.O.) irINTERRUPTER DUPLEX OUTLET O LIGHT FIXTURE <br /> BE AS FOLLOWS: <br /> EXISTING WALL 2.ALL LUMBER RECOMMENDED TO BE FOREST STEWARDSHIP COUNCIL CERTIFIED O THERMOSTAT <br /> VERTICAL FENESTRATION(U-VALUE) 0.28 MIN. DOUGLAS FIR it2 OR BETTER(U.N.O.) 110 V.GROUND FAULT CIRCUIT CEILING MOUNTED 2'x 4' <br /> SKYLIGHT(U-VALUE) 0.50 MIN. Fa INTERRUPTER DUPLEX OUTLET SMOKE DETECTOR LIGHT FIXTURE <br /> 4-'OR 6"INTERIOR STUDWALL- OS <br /> GLAZED FENESTRATION NR3.ALL FINISH MATERIALS NOT SPECIFIED TO BE COORDINATED WITH OWNER AND/OR <br /> CEILING RA9 MIN. 2X4 @ 16"O.C.W/1/2"GYP.BD. ARCHITECT. <br /> SINGLE RAFTERIJOIST-VAULTED CEILING R-38 MIN. EA.SIDE AS NECESSARY AND WEATHER RESISTANT 110 V.GROUND © CARBON MONOXIDE DETECTOR - <br /> BELOW GRADE WALL 10/15/21 INT+TB SOUND BATT INSUL.BTWN.USE tl FAULT CIRCUIT INTERRUPTER <br /> 2X6 WHERE NEC.FOR 4.PROVIDE SOLID BLOCKING BEHIND ALL FIXTURES AND WALL MOUNTED Y DUPLEX OUTLET W/COVER SINGLE TUBE <br /> INSULATED WALLS R-21 MIN.INT ACCESSORIES. COMBO SMOKE AND CARBON )_� MOUNTED UNDER CABINET <br /> SLAB R-10,PERIMETER AND UNDER PLUMBING U.N.O. MONOXIDE DETECTOR <br /> 220-V.DUPLEX OUTLET V G N <br /> ENTIRE SLAB 5.ANY WALLS THAT ARE MODIFIED,REPLACE GYP.BD.W/5/8"TYPE'X'GYP.BD. � <br /> FLOOR R-38 MIN. 4"FURRING CONTINUOUS/R-15 TON ON 110 V.ARC FAULT CIRCUIT a PHONE JACK J m 0 <br /> 8.WHERE(E)STUD WIDTHS VARY FROM NEW WALL TYPE STUD WIDTH,MATCH(E) INTERRUPTER QUAD OUTLET 01 01 <br /> ENERGY CREDIT NOTES THE INTERIOR OF WALL OR 6" STUD WIDTH. N DATA JACK CEILING FAN W Q,, <br /> TOTAL ADDITION OF HEATED FLOOR AREA:900 S.F. FURRING W/R-21 CAVITY Fi ci <br /> 110 V.FLOOR OR CEILING ARC FAULT 2 <br /> ADDITION U IT S.F.=ENERGY EFFICIENCY REQUIREMENTS PER OPT.1,SMALL INSULATION PLUS A THERMAL 7.PROVIDE WALL&FLOOR STOPS AT DOORS AS REQUIRED. R. CIRCUIT INTERRUPTER DUPLEX TV TELEVISION CABLE OUTLET p <br /> DWELLING UNIT=3 CREDITS NEEDED BREAK BETWEEN THE SLAB OUTLET AS NOTED (r- <br /> AND THE BASEMENT WALL AT 8.(E)WALLS REQUIRING OPENINGS TO BE INFILLED SHALL MATCH(E)CONSTRUCTION C.W. F a¢m <br /> FUEL NORMALIZATION CREDITS(1 CREDIT): THE INTERIOR OF THE &FIRE RATING. $ SINGLE POLE SWITCH REFRIGERATOR COLD WATER SUPPLY a CEILING MOUNTED EXHAUST FAN n <br /> FOR AN INITIAL HEATING SYSTEM USING A HEAT PUMP BASEMENT WALL F.P.H.B. YI <br /> THAT MEETS FEDERAL STANDARDS FOR THE EQUIPMENT 9.ALL PLYWOOD SHEATHING RECOMMENDED TO BE FOREST STEWARDSHIP COUNCIL $� THREE WAY SWITCH FROST PROTECTED HOSE BIBB e m am 50 CFM CEILING MOUNTED EXHAUST F Ol N V <br /> LISTED IN TABLE C403.3.2(1)C OR C403.3.2(2) CERTIFIED(U.N,O.). C FAN FOR WHOLE HOUSE VENTILATION w IWyW q <br /> Yo DIMMERSWITCH �- GAS OUTLET = FFm <br /> OPTION 3.4(1.5 CREDITS): © GARAGE DOOR OPENER W/GFCI w d ^ 7-11 <br /> DUCTLESS MINI-SPLIT HEAT PUMP SYSTEM,ZONAL CONTROL:IN HOMES WHERE THE GAS KEY OUTLET AS REQ. w w 1�{� V W 0 <br /> PRIMARY SPACE HEATING SYSTEM IS ZONAL ELECTRIC HEATING,A DUCTLESS MINI- <br /> CEILING MOUNTED LIGHT FIXTURE m Q }2 <br /> SPLIT HEAT PUMP SYSTEM WITH A MINIMUM HSPF OF 10.0 SHALL BE INSTALLED AND _ <br /> ® FLOOR MOUNTED HVAC SUPPLY WEATHER PROOF CEILING MOUNTED <br /> PROVIDE HEATING TO THE LARGEST ZONE OF THE HOUSING UNIT. ® RECESSED CAN LIGHT FIXTURE REGISTER wv LIGHT FIXTURE w a CF J m <br /> OPTION'1.1 CREDITS): FIXTURE I WALL OR SOFFIT MOUNTED HVAC ® WEATHER PROOF RECESSED CAN a Z W ZA <br /> PRESCRIPTIVE COMPLIANCE IS BASED ON TABLE R402.1.1 WITH THE FOLLOWING � WALL MOUNTED LIGHTn <br /> MODIFICATIONS:VERTICAL FENESTRATION U=0.24, SUPPLY REGISTER wr LIGHT FIXTURE d w Z W <br /> I-0 WEATHER PROOF WALL MOUNTED vim 0 N I¢W0 <br /> TOTAL CREDITS PROVIDED:3 CREDITS wa LIGHT FIXTURE rc h N <br /> WEATHER PROOF CEILING FAN C.N. CADET HEATER w df Q <br /> SOUND BATT INSUL. wv a m Q <br /> WHERE OCCURS i N 3 <br /> WALL PER LEGEND o ow <br /> o <br /> ROOF ASSEMBLY o Y <br /> IN)R-15 CONTINOUS WALL-SEE SCHEDULE U o <br /> GYP.BD.EA.SIDE INSULATON i 3 <br /> IN)FURRING PER LEGEND HOLLOW MTL.FRAME OR <br /> EQUAL (2)STUDS AT ALL <br /> 2x4 FLAT 4'-0" BASE EA.SIDE WHERE GYP.BD.ON DOOR-SEE SCHED. JAMB AND HEAD CONDITIONS o 0 <br /> O C OCCURS (E)CONC WALL INSIDE FACE <br /> SWEEP-SEE SCHED. uwiw <br /> PRESSURE TREATED 2X BASE ON INSIDE FACE, HOLLOW METAL FRAME € <br /> 518"GYP.BD.CEIL., PLATE (E)FTG TO REMAIN .. WHERE OCCURS (E)CONC.SLAB z LLo <br /> " .145"DIA.POWDER <br /> PRESSURE TREATED 2X <br /> INTERIOR WALL DRIVEN PINS @ 18" PLATE - - DOOR-SEE SCHEDULE ;o <br /> PER LEGEND O.C. - <br /> -- - .145"DIA.POWDER - F <br /> (N)CONC.SLAB,TYP. - - DRIVEN PINS 0 18"O.C. w <br /> 3 WA L LCEILING (E)CONC.SLAB,TYP. <br /> (N)R-5 RIGID INSUL. m o <br /> INTERIOR WALL TO SLAB o IN- o o THERMAL BREAK J DOOR SILL r DOOR JAMB/HD. o <br /> SUL FTG D <br /> U Q� <br /> 1 12" 1-1/2"0 O.D.WOOD o a; <br /> RAIL,STAIN <br /> ao <br /> - �o <br /> GYP.BD.OR SIDING, <br /> TYP. /�-- 1 - - - z¢ <br /> 2X6 BACKING OR _ z <br /> ATTACH DIRECT TO �� --- <br /> POST,TYP Q MIN 3X3 <br /> LANDING of <br /> BAR AND ATTACHMENT TO f UP) oa <br /> .CESSAFY <br /> SUPPORT 250 POUND 7HANIRAILS <br /> STRESS VERTICAL OR - - y <br /> HORIZONTALODIF a'o Z <br /> OU w <br /> 11 <br /> NDRAIL A21 T RISER: 3/4 AS NAX <br /> MAX TREAD <br /> I1"1 4-0" T-10„ <br /> 13 HA-0" S w N <br /> CAST-IN-PLACE STAIR C —— 802 <br /> STORAGE CL. STORAGE ¢u m <br /> 11"STAIR TREADS,TYP. <br /> 8'•3" EIL _r 0 \ STORAGE za <br /> 7 3/4"MAX RISER,TYP. 6068 BIFOLD <br /> 1 2880 DR. `Ly -I STORAGE 11 m w <br /> MIN.3X3 <br /> .a Q 3'-8" 3'-4 fO LANDING C 3060 DR. 8'-3" EIL HT <br /> s (E)SLAB ON GRADE <br /> ;• MIN AREA OF EGRES 2 "� LDY ~a <br /> LLF <br /> WINDOW:5.7 SF LDY WH WH <br /> MIN WIDTH:20" 3 - O WID FAMILY/BONUS O g <br /> MIN HEIGHT:24" __ ___ J <br /> iv Ari <br /> ___ _ ___ SILL HT.TO BE 3068 DR. 4'-0" 5'•11" L w QM <br /> -- — -- - NOT MORE aj \\ © S W N <br /> STAIR B T THAN4aTO <br /> BEDROOM <br /> 1 INCHES Q (E)POSTS,P. 3088 DR. U <br /> 3 m REMAIN,TYP. o! _ DROOM <br /> (E)FLOOR F i BEDROOM tl'L�BONU m. FABOVE ^� ED EIL HT IL HT 1 c <br /> BE n <br /> CAST4N-PLACE STAIR ?? CL. ©O U _- U <br /> 0 <br /> m �• 2'-9" 7'-ill" EIL HT - -- �.-. / / F <br /> m <br /> m <br /> (E)FLOOR 4088 BIFOLD _ <br /> � <br /> m LINE OF E FTG.ABV.GRADE iv VERIFY <br /> ---._-_. - _ AFl a U z <br /> n 3'-0" " BUILT IN BED <br /> 11"STAIR TREADS, iv CL. () F > <br /> TYP. SHEL LU w <br /> W <br /> ii 7314"MAX RISER: - _. Z <br /> . „ TY SILL HT TO BEE NOT 4036 SL. MIN EA OF EGRESS _ O Y z <br /> a a 7,-10„ T-6" MORE THAN 44 INCHES _. _ - - - _---. <br /> MODIFIED STAIRS <br /> IN WINDOW WINDOW:5.7 SF U 3 <br /> p = <br /> IF DEPTH OF WINDOW WE ILL MN WIDTH:20" coo m <br /> (E)FLOOR WELL>44"(W.F.),PROVIDE MN HEIGHT:24" <br /> PERMANENTLY AFFIXED cN <br /> �� 4'-8" Q W CN <br /> N <br /> LADDER PER IRC R310.2.3, <br /> NORTH TYR 3 s&i NORTH <br /> OF EVERETT U p f <br /> 10'-6'' 15'-e^ 6'-0" 2'-4" REVIEWED FOR PERMIT L o <br /> H i <br /> 0 77 <br /> Z 77 <br /> NEW BASEMENT PLAN NEW BASEMENT ELECTRICAL PLAN � a <br /> 11 =TAIR T 9 STAIR SE TI 1 , a a N o <br /> 2 <br /> J Q 04 <br />
The URL can be used to link to this page
Your browser does not support the video tag.