2300 MERRILL CREEK PKY 2023 ZAP ENERGY Plans 2025-09-12
>
Address Records
>
MERRILL CREEK PKY
>
2300
>
ZAP ENERGY
>
Plans
>
2300 MERRILL CREEK PKY 2023 ZAP ENERGY Plans 2025-09-12
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/12/2025 9:25:06 AM
Creation date
9/12/2025 9:24:52 AM
Metadata
Fields
Template:
Address Document
Street Name
MERRILL CREEK PKY
Street Number
2300
Tenant Name
ZAP ENERGY
Permit
M2307-029
Year
2023
Notes
PROVIDE DUCTING TO PROVIDE COOLING TO SERVER & CONTROL ROOMS
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
4
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2 3 a 5 6 <br /> GENERAL NOTES P 2 S ENG <br /> 1. ALL EQUIPMENT IS EXISTING UNLESS OTHERWISE NOTED. <br /> AS PER 2018 WASHINGTON STATE ENERGY CODE ,.ono 9eecl� I, L.n aroeles <br /> O <br /> C503.4.3,ALTERATIONS OF EXISTING COOUNG SYSTEMS _n�Diec <br /> SHALL NOT DECREASE THE BUILDING TOTAL ` <br /> A 'H ECONOMIZER CAPACITY.PREV10US LOCATION DID NOT <br /> 2 HAVE ECONOMIZER <br /> THEREFORE.ECONOMIZER CAPACITY p2sinc.com <br /> IS NEITHER BEING INCREASED OR DECREASED. <br /> :aI - <br /> _ AS PER 2018 WASHINGTON STATE ENERGY CODE C503.1 <br /> 3 EXCEPTION 1,DOAS NOR ERV IS REQUIRED SINCE <br /> COOLING CAPACITY IS NOT BEING ADDED TO EXISTING 2D <br /> TON VRF UNIT SYSTEM. <br /> FOR SERVER ROOM,SET FCU-1-1 TO73'FAND FCU-I-2TO CONTRACTOR <br /> 75'F.HEATING SHALL OCCUR AT 68'F.EVERY MONTH, <br /> U" 1 USER FORL OLONG CONTR O ROOM,SKALLSWITCHSFOLLOW SEQ INTS TO UENCE OF RUNTIME <br /> OPERATION BELOW. <br /> PIPING IS STACKED VERTICALLY ON WALL SHOWN <br /> 5. HORIZONTAL FOR CLARITY.ALL NEW PIPING SHALL BE <br /> STACKED VERTICALLY ON WALL u burn <br /> _ AllMechanical <br /> NOTES IXWGen performance counts <br /> ❑ 61NCH DUCT TO CONNECT TO EXISTING OUTSIDE AIR <br /> DUCT 61NCHES BELOW ROOF.PROVIDE CLASS I <br /> MOTORM DAMPER IN THE VERTICAL WITH BALANCING <br /> DAMPER AND BALANCE TO 65 CFM.MOTORIZED DAMPER <br /> IS FOR COMPLIANCE WITH 2018 WASHINGTON STATE <br /> ENERGY CODE C403.7.8.1 <br /> DUE TO SITE VISIT UMITAMONS,FCU-1<WAS NOT 7AP ENERGY FACILITY UPGRADE <br /> B f� ----I �_ F'TQ r' __'TJ _ _ ❑ VERIFIED IN THE FIELD.CONTRACTOR SHALL VERIFY <br /> "� .. THAT <br /> RELO UNITATE OCAPAB NEW LE OF3 00 SM SHOWN ON PLANS.IF 2300 Merrill Creek Parkway <br /> Par Prep - -- -- UNIT IS NOT CAPABLE OF35,000BTU/HRTOTALLOAD, Everett,WA 98203 <br /> Vacuum - CONTRACTOR SHALL USE FCU-1-5 AND RELOCATE UNIT <br /> i - TO NEW LOCATION AS SHOWN.CONFIGURE UNIT <br /> INSTALLATION SO THAT CONTROL AND CLEARANCE IS <br /> 210 CD-1 _ OVER THE EDGE OF THE CONTROL ROOM WALL MOUNT <br /> B 600 - — -QIJ — _ UNIT AT HEIGHT$O THAT PUMPED CONDENSATE WILL BE <br /> m,P.�) p / -_ J-f J_- _ ��� --- - ABOVE EXISTING CONDENSATE PIPE SO THAT R MAY <br /> ._ .... _ .... DISCHARGE INTO SINK--_ - <br /> Owner <br /> : �"-' DUCT SHALL PENETMTETHRU TOP OF CONTROL ROOM <br /> - ❑ AREA AND INTO PLENUM ABOVE CEILING.DISTRIBUTE AS <br /> ( 1 SHOWN TO DIFFUSERS.IF NO PLENUM,THEN PENETRATE <br /> 7 .. - TO EACH DIFFUSER LOCATION. <br /> Se•va ERV ❑ DUCT SHALL PENETRATE THRU TOP OF CONTROL ROOM <br /> 1 8 1-1 2 - — AREA AND INTO GRILLE AT CEILING.IF NO PLENUM,THEN <br /> t aO�.r - (Fa I PENETRATE AT GRILLE LOCATION. - - - <br /> - F MMQ ❑ DUCT SHALL DROP TO 2 INCHES BELOW SERVER ROOM <br /> CEILING AND AddiUVeManufatunil_ WALLSNOTRATED TEWALLATLOCATONSHOWN. <br /> 10 - - 8 FCU-1-2 IS EXISTING.REONFIGURETO HAVE DUCT ZAP ENERGY <br /> Rr-1 - - 1 FCU 171``SF FCU _ ❑ CONNECTIONS.CONDENSATE AND REFRIGERANT PIPING <br /> 73 TO REMAIN AS IS. <br /> 1200 1.1 7 DEMOLISH REFRIGERANT PIPING BACK TO POINT SOWN <br /> �.2) g (E) (E) ❑ FOR EITHER FCU-1.4 OR FCU-1S.ROUTE TO LOCATION <br /> C _ _-- - SHOWN ABOVE CONTROL ROOM AREA <br /> EXISTING CONDENSATE COLLECTION PIPING.ROUTE <br /> Ca D ❑ FCU-I.OR FCU-1.5 CONDENSATE FROM NEW LOCATION <br /> 5 5 FCU SHOWN TO COLLECTION PIPING AND CONNECT TO PIPE <br /> 268 J- t8 2 3 IN VERTICAL <br /> 1A Pr;' <br /> (E) = "_ ❑ DUCT SHALL PENETRATE AT LOCATION SHOWN AND <br /> LC - _ - CD-1 CONNECT TO DIFFUSER AS SHOWN. a% <br /> - 1 300 10 FAN COIL UNITAND ASSOCIATED REFRIGERANT PIPING, <br /> (TYPE) CONDENSATE AND DUCTWORK IS ABOVE SERVER ROOM <br /> RG-1 ENCLOSURE DUCT SHALL PENETRATE AT POINTS <br /> FCU 1135 _ - SHOWN ON NOTE B <br /> 6 �F�f,/OA'g71 <br /> 14 <br /> 7/7/2023 <br /> ----- - SEQUENCE OF OPERATION - <br /> FCU FCU 4 _ _ __ 1. FAN COIL SHALL RUN TO MAINTAIN 8B'F-7SF(ADJ)AS <br /> 13 l i -L-IS <br /> - - DETERMINED BY ROOM THERMOSTAT. Revisions <br /> Lab - 2- UPON ACALL FOR COOUNGMEATING,MANUFAC URER5 Number Desaiption QBIe <br /> PERATURE <br /> � Wet _ _ SETPNOMr FOR LEAVE El ROOM.PRIIMARY FAAINTAIN ANNACOIL SHALL <br /> OPERATETOMAINTAIN 73F AND SECONDARY FAN OILX X)(J)Q(�)0(1235 SF - SHALLOPERATETOMAINTAIN 7SF.HEATING SHALL ONLY <br /> OCCUR TO MAINTAIN 68'F <br /> 3. FAN SHALL OPERATE ONLY AS NEEDED TO MAINTAIN <br /> Safety _ i Room ✓ 1. F SHALLOPEFATEN ERATURE IN TEE�ROCCUPANCY IS DETECTED BY <br /> --- ' r �- li -'JU-J�"-- ROM.WHEN <br /> ENSORNEITHER <br /> HEATING <br /> GO COOLIOURS NG <br /> CONTROL <br /> _t 92 SF - — _I _ ROOM.ED.FA NEITHER HEATING T COUNG IS <br /> __ - -- -- - _ „ _ - T ." I REQUIRED,FAN ICALL ADJUST AT PER <br /> EST MANUFACTURERS <br /> .FAN <br /> - - - - ,. SHALL AUTOMATICALLY ADJUST AS PER MANUFACTURERS <br /> INTERNAL SEQUENCE OF OPERATION WHEN <br /> COOUNGMEATING S REQUIRED. <br /> -- _. .ir .�. I_-._I .. - <br /> J Designed PJA <br /> Drawn PJA <br /> ----- - - —'- — -- --. - - ____---- Checked DS <br /> - - --------- _ Approved SP <br /> Date X <br /> I <br /> 0 <br /> 2 Submittal X <br /> Z <br /> c <br /> Scale <br /> Sheet Title E <br /> MECHANICAL <br /> MECHANICAL: SERVER AND CONTROL ROOM HVAC SERVER AND CONTROL <br /> g SCALE:1/8"=r-0" ROOM HVAC <br /> CITY OF EVERETT <br /> REVIEWED FOR PERMIT Sheet Number <br /> M201c� <br /> P2S No.XXXX <br />