INITIATING WIRING RECORD DRAWINGS <br /> AS-BUILT/RECORD DRAWING REQUIREMENTS: Conve rg j nt <br /> SIGNATURE LOOP WIRING LIMITATIONS: Z <br /> THE FOLLOWING INFORMATION SHOULD BE RECORDED ON A SEPARATE SET OF O <br /> SIGNATURE DUAL DRIVER CONTROLLER MODULES SUPPORTS UP TO 250 DRAWINGS FOR EACH PROJECT: <br /> INTELLIGENT SIGNATURE DETECTORS AND 250 INTELLIGENT SIGNATURE W 450 Shattuck Avenue South,Renton,Washington 98057 <br /> MODULES 1. ANY CHANGES IN THE LOCATION OF ANY ASSOCIATED FIRE ALARM OR o Phone:425-272-2250 Fax:425-251-0949 <br /> WIRE LENGTH LIMITATIONS: INTERFACE EQUIPMENT.CONTROL PANELS,ANNUNCIATORS,DETECTORS, w <br /> CONTROL RELAYS,INPUT AND OUTPUT MODULES,TERMINAL CABINETS, zYO ¢ w <br /> NON-TWISTED,NON-SHIELDED WIRE ETC. F w p This dowmentand the inro�mation/aepiaions conrainea/shown <br /> 16AWG-20pf/FT&4.02 OHMS/1000 FEET 2. ANY CHANGES TO CIRCUIT WIRING.THIS INCLUDES DELETION OR W o O is Me exclusive property of Convergint Technologies LLC and shall <br /> 18AWG-20pfIFT 8 6.38 DHMS/1000 FEET ADDITIONAL WIRING RUNS.ANY RE-ROUTING OF CIRCUIT WIRING.ANY SEQUENCE O F OPERATIONS �i w m w ~ be hantllea as proprietary antl wnftlential information aria must be <br /> DETECTORS ONLY 1 <br /> 6AWG-125 DETECTORS-9,275' ADDITIONS OR DELETIONS TO THE NUMBER,LOCATION,AND ORDER OF ¢ o Yo o O m w w —ned upon request.This document pnnot be rep.duc.d by any <br /> MODULES ONLY 16AWG-125 MODULES DEVICE WIRING ON A CIRCUIT. z 0 < w mO ¢ w m ns without the wdnen eutnorizelion of convergent Technologies LLC. <br /> DETECTORS AND MODULES 16AWG-125 OF EACH-3,608' 3. ADDRESSES AND/OR LABELS FOR ALL ADDRESSABLE DEVICES. ¢ 2 _ G <br /> DETECTORS ONLY 16AWG <br /> -125 DETECTORS-5,839' 4. CANDELA SETTINGS OF ALL VISUAL NOTIFICATION DEVICES. F <br /> MODULES ONLY 18AWG-125 MODULES-4,986' 5. WATTAGE TAP SETTINGS OF ALL SPEAKER NOTIFICATION DEVICES. p O <br /> DETECTORS AND MODULES 18AWG-125 OF EACH-2,271' <br /> ANY CHANGES SHALL BE DISCUSSED WITH CONVERGINT PROJECT MANAGER Z <br /> TWISTED PAIR.NON-SHIELDED WIRE TO ENSURE SYSTEM AND CODE PARAMETERS ARE MET.CONVERGINT SHALL a <br /> i6AWG-36pf/FT&4.02 OHMS/1000 FEET NOT BE HELD ACCOUNTABLE FOR CHANGES MADE WITHOUT APPROVAL. <br /> 18AWG-25pf/FT&6.38 OHMS/1000 FEET <br /> DETECTORS ONLY 16AWG-125 DETECTORS-9,275' THIS INFORMATION SHALL BE NEAT AND LEGIBLE WHEN PRESENTED TO THE <br /> MODULES ONLY 16AWG-125 MODULES-7,921' TECHNICIAN AT THE CONCLUSION OF THE PROJECT.PLEASE NOTE CONTACT <br /> DETECTORS AND MODULES 16AWG-1250F EACH-3,608' INFORMATION ON DRAWINGS FOR INDIVIDUALS WITH FAMILIARITY OF <br /> DETECTORS ONLY i8AWG-125 DETECTORS-5,839' INSTALLATION IN THE EVENT QUESTIONS ARISE DURING THE CLOSEOUT <br /> MODULES ONLY 1BAWG-125 MODULES-4,986' PROCESS. ACTIVATION OF LOCALALARM AT LIT&2120 HEADEND(LED DISP,ZON F LED&AUDIBLE IND.) X X X X X X X <br /> DETECTORS AND MODULES 18AWG-125 OF EACH-2,271' <br /> TWISTED PAIR,SHIELDED WIRE ACTIVATE ALL AUDIBLE&VISIBLE ALARMS x x x x x x <br /> 1 <br /> 6AWG-82pf/FT&4.02 OHMS/1000 FEET <br /> 18AWG-58pf/FT&6.38 OHMS/1000 FEET <br /> DETECTORS ONLY i6AWG-125 DETECTORS-6,098' INDICATION OF ALARM ON ANNUNCIATOR <br /> MODULES ONLY 16AWG-125 MODULES-6,098' <br /> DETECTORS AND MODULES 16AWG-125 OF EACH-3,608' INITIATE PRIMARY ELEV.RECALL SEQUENCE TO MAIN FLOOR(IF APPLICABLE) x <br /> DETECTORS ONLY i8AWG-125 DETECTORS-5,839' <br /> MODULES ONLY 18AWG-125 MODULES-4,986' <br /> DETECTORS AND MODULES 18AWG-125 OF EACH-2,271' INITIATE ALTERNATE FLEV.RECALLSEQUENCE TO FIRST FLOOR(IF APPLICABLE) x <br /> SIG—RE—LOQP WRING,CLASS B ONLY RELEASE ALL DOOR HOLDERS&CLOSURES ON FLOOR IN ALARM(OR GEN.ALARM) x x x x x x <br /> TRAMSMIT TROUBLES,SUPERVISORY X X X X X X <br /> s 00 s 00 TRANSMITALARM SIGNALTO CENTRALSTATION MONITOR x X X X x x <br /> SHUTDOWN RESPECTIVE HVAC FAN x <br /> TROUBLE INDICATION ON FACP&ANNUNCIATOR x x <br /> TRANSMITTROUBLE SIGNAL TO CENTRAL STATION MONITOR X X <br /> 0 <br /> STAR-TAPPING.UNACCEPTABLE <br /> NOTIFICATION WIRING <br /> SPEAKER CIRCUIT WIRING LIMITATIONS: <br /> WIRE LENGTH LIMITATIONS: <br /> THE MAXIMUM ALLOWABLE WIRE LENGTH IS THE FARTHEST DISTANCE THAT A <br /> SPEAKER CIRCUIT CAN EXTEND FROM THE AMPLIFIER TO THE LAST SPEAKER <br /> WITHOUT LOSING 0.5 dB OF SIGNAL.THE FOLLOWING ARE MAXIMUM DISTANCE <br /> BASED ON APPROXIMATE WATTAGE OF THE SPEAKER CIRCUIT.CIRCUIT LENGTHS <br /> ARE FURTHER BASED ON ORIGINATION OF A CIRCUIT FROM EITHER THE <br /> AMPLIFIER OR FROM THE CC1 MODULE. <br /> ALLOWABLE LENGTH AT 25 V-S,WITH 0.5 dB LOSS <br /> 16AWG-20 WATTS-231' <br /> 16AWG-30 WATTS-154' <br /> 16AWG-40 WATTS_1 16, <br /> ALLOWABLE LENGTH AT 70 V-S,WITH 0.5 dB LOSS <br /> 16AWG-20 WATTS-1815' <br /> 16AWG-30 WATTS-1210' <br /> 16AWG-40 WATTS-907' <br /> NAC CIRCUIT(HORN,STROBE)WIRING LIMITATIONS: <br /> FOR 24VDC SYSTEMS,MINIMUM DEVICE OPERATING VOLTAGE IS 16VDC. <br /> VOLTAGE DROP CALCULATIONS ARE BASED ON 16VDC AND POWER SUPPLY <br /> DE-RATED AND ON DEPLETED BATTERY BACKUP PER THE PRESCRIBED PERIOD <br /> OF STANDBY AND ALARM RING TIME.THE VOLTAGE DROP WILL LIMIT THE <br /> CIRCUITS CAPACITY IN ALMOST ALL CASES AND CURRENT CANNOT BE USED AS <br /> THE ONLY CIRCUIT WIRING LIMITATION.ALTERATIONS TO CIRCUIT LENGTH <br /> FROM THOSE CALCULATED MAY CAUSE CIRCUITS TO BE OUT OF THE <br /> TOLERANCES GRANTED BY THE FIRE ALARM CODE.CHANGES TO DEVICE <br /> LOCATION OR CIRCUIT LENGTH SHALL BE COMMUNICATED TO THE CONVERGINT <br /> TEAM. <br /> NAC CIRCUIT WIRING AND ROUTING MUST NOT EXCEED WHAT IS SHOWN ON THE <br /> DESIGN DRAWINGS AND CALCULATIONS.A VOLTAGE DROP TEST IS PART OF <br /> MOST FIRE FINALS AND IS REQUIRED BY NFPA.A FAILED FIRE FINAL MAY <br /> REQUIRE REWIRING OF THE FAILED CIRCUITS. <br /> WIRE RESISTANCE RATINGS USED FOR CALCULATIONS: <br /> 18AWG-13 OHMS PER 1000' <br /> 16AWG-8 OHMS PER 1000' <br /> 14AWG-5.2 OHMS PER 1000' <br /> EXAMPLE: 1.0 AMP CIRCUIT LOAD USING#14 WIRE=409 FEET MAXIMUM. <br /> CLASS A OR B NOTIFICATION WIRING <br /> EOL <br /> FACP <br /> OR EOL RESISTOR ON <br /> NAG NON ADDRESSABLE <br /> CIRCUITS <br /> DEVICE DEVICE <br /> CLASS B,STYLE 4 WIRING <br /> iosx-DescalPnox DATE <br /> FACP <br /> OR <br /> NAC <br /> DEVICE DEVICE <br /> } <br /> a <br /> 0MIAH R. <br /> Q PROJECT DESIGNER: xGBExTR <br /> QW CLASS A POWER REQUIREMENTS <br /> ,STYLE 6 WIRING <br /> U <br /> 1n EACH MAIN FIRE ALARM PANEL REQUIRES(1)120VAC,20AMP DEDICATED <br /> Q SEPARATION OF CLASSACIRCUITS-INSTALLATIONEXCEPTION& CIRCUIT. PROVIDENCE PACIFIC CAMPUS <br /> F CLASS AOUTGOING AND RETURN CONDUCTORS,EXITING AND RETURNING EACH NAC BOOSTER PANEL REQUIRES(1)120VAC,15AMP DEDICATED CIRCUIT. ELEVATOR T.I. <br /> TO THE CONTROL PANEL,ARE TO BE ROUTED SEPARATELY.THE MINIMUM 916 PACIFIC AVE <br /> v RECOMMENDED SEPARATION IS 1 FT.VERTICALLYAND 4 FT. IN BUILDINGS EMPLOYING EMERGENCY STANDBY POWER SYSTEMS,THE FIRE EVERETT,WA,98201 <br /> x HORIZONTALLY.THE FOLLOWING EXCEPTIONS STILL DO NOT ELIMINATE ALARM SHALL BE SUPPLIED WITH EMERGENCY POWER.THIS IS REQUIRED IN <br /> THE 2ND PAIR OF WIRES.THEY ALLOW YOU TO USE A SINGLE RACEWAY HIGH-RISE AND SMOKE CONTROL APPLICATIONS.ALL OTHER APPLICATIONS <br /> M AND ELIMINATE THE SEPARATION FOR THESE CONDITIONS. ARE SUBJECT TO LOCAL BUILDING AND ELECTRICAL CODES. <br /> z 1. WHEN MAXIMUM CABLE,ENCLOSURE,OR RACEWAY IS LESS THAN 10 WHERE THE FIRE ALARM SYSTEM IS CONNECTED TO EMERGENCY NOTES <br /> FEET.NO LIMIT TO NUMBER OF DEVICES. POWER,THE FIRE ALARM SYSTEM MONITORS THE GENERATOR FOR <br /> 1n 2. UNLIMITED CONDUIT OR RACEWAY DROP TO AN INDIVIDUAL DEVICE. RUNNING,FUEL LOW AND TROUBLE STATES. <br /> 0 3. UNLIMITED CONDUIT OR RACEWAY DROP TOA ROOM NOT FIRE ALARM SYSTEM <br /> Z EXCEEDING 1000 SO,FT.NO LIMIT TO THE NUMBER OF DEVICES. FOR ADDITIONAL DETAILS,REFER TO NFPA 72,CHAPTER 10. <br /> Q wgNc. <br /> o FA-0-2 <br /> LL <br />