Laserfiche WebLink
STRL JRAL CALCULATIONS by WOODWAY HOMES, <br /> 6306 176th St SW, Lynnwood,WA 98037 (425)772-3167 <br /> BeamChek v2022 licensed to:WOODWAY HOMES INC. Reg#8101-1582 <br /> TUGGLE FIRE REPAIR REPLACEMENT RAFTERS <br /> OVER LAUNDRY ROOM Prepared by:DD.AIA Date:7/25/22 <br /> Selection 2x 4 HF#2 @ 24 in oc Lu=0.0 Ft <br /> Conditions NDS 2018, Repetitive Use <br /> Min Bearing Area R1=0.5 in2 R2=0.5 in2 (1.5) DL Defl= 0.13 in <br /> Data Beam Span 6.0 ft Reaction 1 LL 150# Reaction 2 LL 150# <br /> Beam Wt per ft 1.28# Reaction 1 TL 214# Reaction 2 TL 214# <br /> Bm Wt Included 8# Maximum V 214# <br /> Max Moment 321 '# Max V(Reduced) 193# <br /> TL Max Defl L/180 TL Actual Defl L/210 <br /> LL Max Defl L/180 LL Actual Defl L/345 <br /> Attributes Section (in3) Shear(in2) TL Defl(in) LL DefI <br /> Actual 3.06 5.25 0.34 0.21 <br /> Critical 2.28 1.68 0.40 0.40 <br /> Status OK OK OK OK <br /> Ratio 75% 32% 86% 52% <br /> Fb(psi) Fv(psi) E(psi x mil) Fc l (psi) <br /> Values Reference Values 850 150 1.3 405 <br /> Adjusted Values 1686 173 1.3 405 <br /> Adjustments CF Size Factor 1.500 <br /> Cd Duration 1.15 1.15 <br /> Cr Repetitive 1.15 <br /> Ch Shear Stress N/A <br /> Cm Wet Use 1.00 1.00 1.00 1.00 <br /> Cl Stability 1.0000 Rb=0.00 Le=0.00 Ft <br /> Loads Uniform LL:50 Uniform TL:70 =A <br /> AUG 2 6 2022 <br /> CITY OF EVERETT <br /> Permit Services <br /> Uniform Load A <br /> 0 0 <br /> R1 =214 R2=214 <br /> SPAN=6 FT 6417 ISTsFXM <br /> Uniform and partial uniform loads are Ibs per lineal ft. ITZCT <br /> I \ <br /> r � <br /> DEAN C D OTIS <br /> STATE OF SmSSZNGTON <br />