My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3201 SMITH AVE 2024 BASE FILE Plans 2025-09-12
>
Address Records
>
SMITH AVE
>
3201
>
BASE FILE
>
Plans
>
3201 SMITH AVE 2024 BASE FILE Plans 2025-09-12
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/12/2025 1:56:58 PM
Creation date
9/12/2025 1:56:56 PM
Metadata
Fields
Template:
Address Document
Street Name
SMITH AVE
Street Number
3201
Tenant Name
BASE FILE
Permit
FA2402-011
Year
2024
Notes
INSTALL A WIRELESS FIRE ALARM COMMUNICATOR
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
Page 1 of 1
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Permit#: FA2402-011 ? <br /> QTY O E V E s E T T T 0 0 T 0 T 0 Site Address 3201 Smith Ave <br /> Applicant: Fire Protection Inc <br /> Application Date:02/19/2024 FIRE PROTECT/ON INC. <br /> Description: Install a Wireless Fire Alarm 17 Ash Way,Ste 8 <br /> Communicator Lynnwood,WA 98037 <br /> Review Date: 02/21/2024 425-290-9600 <br /> FPISEATTLE.COM <br /> AES RADO � NSTALLAT OR ` <br /> EVERETT `,r <br /> Everett Fire Dept.Permit Review <br /> Status:Approved <br /> Reviewed By:KBrown <br /> 02/21/2024 12:39:45 <br /> REPORTING ZONE FROM RADIO TYPICAL INSTALLATION DETAIL SHEET/NDEX PM NFPA® <br /> SHEET # SHEET DESCRIPTION 000805173 <br /> FA 0.0 FIRE ALARM AES INSTALLATION ROY L CATS <br /> CENTRAL STATION REPORTING ZONES <br /> QpOTECTj <br /> ZONE # ZONE DESCRIPTION PROJECT DETAILS �Q0 <br /> 1 GENERAL ALARM LL 4 N <br /> 2 SUPERVISORY 1. THE EXISTING SEVEN-STORY BUILDING IS FULLY-SPRINKLED AND HAS AN EXISTING ADDRESSABLE FIRE ry NFPA �^ <br /> ALARM CONTROL PANEL(SIMPLEX 4100 FIRE PANEL) LOCATED IN THE BASEMENT. <br /> 3 TROUBLE CFPS <br /> 2. ANEW UL LISTED WIRELESS RADIO COMMUNICATOR (7707-88-ULP) IS BEING INSTALLED, SIGNALS WILL BE <br /> TRANSMITTED BY ZONE TO THE UL LISTED SUPERVISING STATION. A 12VDC 12Ah BATTERY WILL BE #1473 <br /> INSTALLED IN THE NEW AES RADIO. <br /> 00 C. 3, <br /> THE NEW AES RADIO WILL USE THE EXISTING FACPs DIALER TO SEND CONTACT ID AND ONBOARD RELAYS <br /> TO TRANSMIT THE FOLLOWING HARDWIRED SIGNALS TO THE CENTRAL SUPERVISING STATION: ZONE 1: FIRE <br /> ALARM /WATERFLOW, ZONE 2: SUPERVISORY, AND ZONE 3: TROUBLE. m <br /> VICINITY MAP o 0 0 0 0 :r <br /> 0O C. 4. NO CHANGES TO THE EXISTING SYSTEM WILL BE MADE, NO ADDITIONAL WORK IS INCLUDED IN THIS SCOPE. - q <br /> n® ❑0 0 0 0 0 wZ ao <br /> �t--�. srAius mnxcnrorts Z w � <br /> O Oo O V W <br /> O O wmmAy PROJECT CONTACT INFO w y a ro <br /> coo <br /> ® 0 aE,!Jg rc <br /> Fao,wF S, ALARM � ® � OWNER/TENANT FIRE ALARM CONTRACTOR <br /> DELTA JUNCTION ,�M, O O COE-ACCOUNTING DIVISION FIRE PROTECTION INC a o <br /> PO BOX 12130 17410 ASH WAY, Ste 8 =°y w a <br /> Providence OPP1E1LO�' TOw EVERETT, WA 98206 LYNNWOOD, WA 98037 y c LL F o <br /> CONTACT RUSSELL DANCE CONTACT DAVID MOW m w G <br /> QRegional PHONE 425.257.8846 PHONE 425.290.9600 z 3 w <br /> Medical Center Spencer RDANCE�FVERETTWA.GOV DAVID®FPISEATTLE.COM wa.e R <br /> island T` ' ` ' ` ' ` <br /> O 100000000 O orcwa�a o <br /> ZONES 1-8"Un REVISION RECORD <br /> © TR GGERS CODE INFO DATE/DESCRIPTION <br /> I Is <br /> maae0amaa arz Te Ts <br /> AUTHORITY HAVING JURISDICTION CITY OF EVERETT <br /> State Route FIRE CODE : INTERNATIONAL FIRE CODE, 2018 EDITION <br /> 3201 Smith Ave, BUILDING USE AND OCCUPANCY : (B) - SPRINKLED <br /> EVERETT EVBf1111I WA 98201 / <br /> STANDARDS: 2018 IBC IFC, 2017 NFPA 70, 2016 NFPA 72, CITY OF EVERETT STANDARDS <br /> JUNCTION I I o ocni oei ovac <br /> CLASSIFICATION OF SUPERVISING STATION : CENTRAL SUPERVISING STATION <br /> 12v12Ah REMOTE SUPERVISING STATION : SECURITAS, INC. <br /> iOwiII \ BA TTr ER PRIME FIRE ALARM CONTRACTOR : FIRE PROTECTION, INC. <br /> PARCEL NUMBERS 00439074401300 <br /> I <br /> • ` �_PINENURST. EXISTING ADDRESSABLE FACP(S"LEX4100 FIRE PANEL) INSTALLATION NOTES <br /> 1 � AES-7707-88-ULP RADIO COlM�JN[CATOR <br /> TYPICALVARMANDINSTALLATIONDETAIIS 1. ALL WORK SHALL BE IN ACCORDANCE WITH NFPA STANDARDS AND ALL LOCAL ADOPTED CODES. <br /> 2. ALL CIRCUITS MUST BE TESTED FOR OPENS, CONTINUITY, SHORTS, AND GROUNDS. <br /> 3. INSTRUCTIONS FOR THE OPERATING, TESTING AND MAINTENANCE OF THE SYSTEM, ALONG WITH RECORD <br /> DRAWINGS OTHERWISE REFERRED TO AS ("AS-BUILT") AND EQUIPMENT SPECIFICATIONS SHALL BE <br /> PROVIDED TO THE OWNER ONCE THE FIRE ALARM SYSTEM HAS BEEN ACCEPTED BY THE AHJ. . <br /> SITE PLAN SEQUENCE OF OPERATIONS <br /> 4. ALL SYSTEMS AND DEVICES SHALL BE INSTALLED AND TESTED PER THE MANUFACTURES LISTING AND THE <br /> AUTHORITY HAVING JURISDICTION (NFPA72 10.14.2.1). DATE: 02/15/2024 <br /> SYSTEM OUTPUTS 5. THE SYSTEM WILL BE 100% PRE-TESTED, AN NFPA 72 COMPLETION FORM WILL BE FILLED OUT AND PROJECT NAME <br /> Required Fire Safety Control PROVIDED TO THE AHJ AND THE ELECTRICAL PERMITS MUST BE SIGNED OFF PRIOR TO THE FIRE FINAL INSPECTION. <br /> Central Supervising Station mm <br /> Control Unit Annunciation 6. THE AES RADIO REQUIRES A DEDICATED 120VAC 20AMP CIRCUIT. A NOTICE PLACED IN THE FACP SHALL <br /> PACIFIC AVE ti �m DIRECT PERSONNEL TO THE LOCATION OF THE ELECTRICAL PANEL THAT IS SUPPLYING DEDICATED POWER <br /> oc TO THE SYSTEM (NFPA72, SECTION 10.5.5.1). THE DEDICATED CIRCUIT BREAKER THAT SERVES THE FIRE <br /> c yE o ;V me me ALARM SYSTEM SHALL BE LABELED AND SECURED AGAINST TAMPERING WITH A RED BREAKER LOCKOUT Z <br /> coz y (NFPA72, SECTION 10.5.5.2). Q <br /> .c°j q��m tuF F- O <br /> ;F. a m �w �o Q W N <br /> �� DEVICE INSTALLATION REQUIREMENTS W Q CO <br /> W Z x <br /> �jQ <br /> W Q — <br /> ®z e°y y FIRE ALARM DEVICE INSTALLATION REQUIREMENTS UL C <br /> Ja O� O q 3 m NOT PERMITTED IJJ <br /> m m m m go,�� o BRAG°ET DIFFUSER HERE a" >- <br /> O <br /> INE AV Q m '�.0 ACT <br /> 2 D D D �m a4 o m a m J-eox cRlo R ~ N M ; <br /> D Q F Q.�. y ^� mJ {J LL <br /> < m m�m c c Cm�cmF m '� FA DEVICE DCEILING ITY,ETECTOR /fit SMOKE 4 U W W <br /> tm MINIMUM 3' W <br /> Q Q Q Q Q Ilrr AWAY FROM NOT PERMITTED 12 <br /> SYSTEM INPUTS B C D E F G H I HVAC DIFFUSERS HERE <br /> SMOKE <br /> 1 Manual Fire Alarm Pull-Station ♦ ♦♦ 1 H <br /> 32ND ST 2 Smoke&Heat Detectors ♦ ♦♦ 2 <br /> a 3 wet a Dry WaterRow ♦ ♦ ♦♦♦ 3 J SHEET TITLE <br /> 4 Smoke Beams MAX HEICHT ez"aF.F ® a <br /> ♦ ♦ ♦♦ 4 MIN HEIGHT 82"A.F.F IEFd 3 <br /> IL 5 Sprinkler Tamper/1 ♦ ♦ 5 <br /> FACP : FIRE ALARM <br /> to 6 Duct Detector ♦ ♦ JH <br /> `n <br /> IN BASEMENT O z PROJECT DETAILS <br /> 7 Fire Alarm AC Power Failure ♦ ♦ <br /> ///��� W 8 Fire Alarm System Low Battery ♦ ♦ fifi•A.F.F fio•A.F.F puLL <br /> 9 Open Circuit ♦ ♦ aa"A.F.F <br /> N10 Ground Fault ♦ ♦ SHEET NUMBER <br /> A B C D E F G ISHED K <br /> Not to Scale FA <br /> O.O <br />
The URL can be used to link to this page
Your browser does not support the video tag.