LUCAS SITE VISIT I July 18, 2024 SDA Job# 10052 9 <br /> MAIN FRONT I A15-WSW ISEUMENTED WALL <br /> Floor Info <br /> 2ND I Floor Level,e.g.Roof,4TH,3RD,2ND Tributary Area(ROOF) Tributary Area(ROOF) <br /> Lt-Rt Load Direction,e g Left-Right,Front-Rear 1.0 tributary width 1.0 tributary area <br /> 2.0 total width 2.0 total area <br /> HF2 Stud Wall Species/Grade Tributary Area(2ND) Tributary Area(2ND) <br /> Structural Panels-Sheathing Sheathing type(T4 3A of SDPWS-2021) 1.0 tributary width 1.0 tributary area <br /> 1,00 Redundacy(p)for Seismic Force-Resisting System(ASCE7-16§12 3 4) 2.0 total width 2.0 total area <br /> 2ND/FL I Resisting Dead Load Tributary Area(NA) (D Tributary Area(NA) z <br /> Shearwall Segment Lengths: Ad: Total Lenym= 10.9 ft tributary width o tributary area a <br /> 10.9 ft tEotal width ao total area o <br /> Tributary Area(NA) o Tributary Area(NA) U <br /> IV(ROOF)= 1420 lb IV(ROOF)= 1748 lb -::]tributary width Z tributary area w <br /> IV(2ND FLOOR)= 2688 lb IV(2ND FLOOR)= 926 lb total width 3 total area <br /> FV()= 0lb EV()= 0lb <br /> IV()= 0 lb IV()= 0 lb Height of Shearwall= 8.0 ft Weight of Shearwall= 10.0 Ibs <br /> F(Wind)= 4,108 lb F(Smc)= 2,674 lb Length of Shearwall= 10.9 ft Tributary width for dead load= 2.3 ft <br /> ULT.v= 189 PLF ULT.Vx p= 123 PLF Aspect Ratio OK Length of adjoining wall= 4.6 ft <br /> 2,054 lb 1.337lb R= 6.5 <br /> ASD SHEAR WALL DESIGN PER:SDPWS-2021 110= 2.5 <br /> ULT.WIND CAPACITY:1 x 0.93 x 730 PLF/(2 x 0.6)=666 PLF <br /> ULT.SEISMIC CAPACITY:1 x 0.93 x 730 PLF 12.8 x 0.7 =346 PLF <br /> Holdown Above:I ROOF FRONT Seismic controls shearwall design <br /> ASD C TOTAL= (floor above)+(this floor)= 1330 Ibs Seismic controls-C3(ASD eq 8): <br /> ASD T TOTAL w/o 00= (floor above)+(this floor)= 558 Ibs Seismic controls-T2(ASD eq 10): <br /> LRFD T-TOTAL w/o DO= (floor above)+(this floor)= 930 Ibs Wind controls-T1(LRFD eq 5): SHEARWALL TYPE: 1 <br /> UNFACTORED OVERTURNING Chord Post/Holdown Info <br /> LOADING 4x HF2 Size/Species/Grade FTAO HOLDOWNS REQUIRED, USE CS20 <br /> LOAD [T] [C] LRFD Ductile Design Criteria/Anchor P <br /> WL -2089lbs 2060lbs 1o.6ft Calculated Effective Width STRAPS ABOVE AND BELOW THE WINDOW, <br /> EQ -1638lbs 1638lbs SHEARWALL 1 <br /> DL 1287 Ibs 1287 Ibs F7N_O ]Manually Enter Effective Width? Ye <br /> LUSL 628lbs 628lbs <br /> MAIN REAR A15-WSW SEGMENTED WALL <br /> Floor Info <br /> 2ND Floor Level,e.g Roof,4TH,3RD,2ND Tributary Area(ROOF) Tributary Area(ROOF) <br /> Lt-Rt Load Direction,a g.Left-Right,Front-Rear 1.0 Itributary width 1.0 tributary area <br /> 2.0 total width 2-0 total area <br /> HF2 Stud Wall SpeciesfGrade Tributary Area(2ND) Tributary Area(2ND) <br /> Structural Panels-Sheathing I Sheathing type(T4 3A of SDPWS-2021) 1.0 tributary width 1.0 tributary area <br /> 1,00 I Redundacy(p)for Seismic Force-Resisting System(ASCE7-16§12.3.4) 2.0 total width 2.0 total area <br /> 2ND/FL Resisting Dead Load Tributary Area(NA) Tributary Area(NA) z <br /> Shearwall Segment Len th& A' T�oital Len th= 16.0 ft tributary width K tributary area a <br /> 16 0 ft total width total area O <br /> Tributary Area(NA) o Tributary Area(NA) <br /> IV(ROOF)= 1420 lb IV(ROOF)= 1748 lb tributary width K tributary area w <br /> IV(2ND FLOOR)= 2688 lb IV(2ND FLOOR)= 926 lb total width �' total area " <br /> FV()= 0lb FV()= 0lb <br /> IV()= 0 lb IV()= 0 lb Height of Shearwall= 8.0 ft Weight of Shearwall= 10.0 Ibs <br /> E(Wind)= 4,108 lb E(Smc)= 2.674 lb Length of Shearwall= 16 0 ft Tributary width for dead load= <br /> ULT.v= 128 PLF ULT.Vx p= 84 PLF Aspect Ratio OK Length of adjoining wall= <br /> R= 6.5 <br /> ASD SHEAR WALL DESIGN PER:SDPWS-2021 no= 2.5 <br /> ULT.WIND CAPACITY:1 x 0.93 x 730 PLF/(2 x 0.6)=566 PLF <br /> ULT.SEISMIC CAPACITY:1 x 0.93 x 730 PLF/ 2.8 x 0.7 =346 PLF <br /> Holdown Above:1 ROOF REAR Seismic controls shearwall design <br /> ASD C TOTAL= (floor above)+(this floor)= 963 Ibs Seismic controls-C3(ASD eq 8): <br /> ASD T.TOTAL w/o 00= (floor above)+(this floor)= 413 Ibs Seismic controls-T2(ASD eq 10): <br /> SHEARWALL TYPE: 1 <br /> WSP <br /> UNFACTORED OVERTURNING Chord Post/Holdown Info <br /> LOADING 4x HF2 Size/Species/Grade Chord Post 2-2x4 <br /> LOAD [T] [C] ASD Ductile I Design Criteria/Anchor Failure Ft'g Holdown,Use? Yes OK- <br /> WL -1495 Ibs 1457 Ibs 15.8 ft Calculated Effective Width Framing Strap,Use' No NOT USED <br /> EQ -1188 Ibs 1188 Ibs Framing HDU,Use? No NOT USED <br /> DL 917 Ibs 917 Ibs No Manually Enter Effective Width?(Yes/No) <br /> LL/SL 82lbs 82lbs <br />
The URL can be used to link to this page
Your browser does not support the video tag.