Laserfiche WebLink
5LIDIN6 <br /> _ L <br /> SELF ADHE50.S -- //— PER PL,k EXTEND MIN.6'UP JAMB ._._..._.__.- <br /> __ <br /> MEMBRANE PAN II / �—SLIGINL .LA.5?Ok ' <br /> FLASHING — -' / NAIL FLINGL <br /> NAIL ON FLEXIBLE \ / 'ALA rLA.-.Idd. NERVA5TRAL TO EXTEND <br /> 2"MIN FROM OF OF f <br /> FLASHING �\ '/ 2'PAST THE INTERIOR \L-HEADER/ '�I \ HEADER/ <br /> FLOOR JOLT � ��� �) /i � �LEDGERTO LAG OF THE DOOR REW STUD <br /> PER PLAN 5/4s,CEDAR DECKING \ / \ / <br /> ROUGH ROUGH <br /> - - PER FLAK WATER IS-PC OP NING OPENING <br /> ... - .pl _ <br /> r--- -2x FT .IBIS T PER PLAN i - JAMB\ JAMB\ - <br /> .�1 -HANGER PER PLAN JOINT I 2ND PIECE / SILL <br /> INSiA I <br /> N MGD 1 <br /> RIM J01 1 - i - PENETRATION <br /> _ - - IS PIfC / 12" 6' <br /> -- PT LEDGER PER.P;,il CONTA T 7 <br /> 11 <br /> BUILDING PAPER—I II SHEATHING PER FLAN f 11 '!� II <br /> INSTALLED BEYND ,/ SILL n <br /> SIDIN;rE <br /> LEDGER AND PAN SIDING PER PLAN PLAN - - ATTACH SILL STRIP OF 9"WI Y <br /> FLASHING <br /> r BUILDING PAPER TO EXTEND <br /> FLASHING LAP %�� ;/,- MIN.12'BEYOND ALL EDGES STEP I STEP 2 <br /> OVER HOUSE vdRAP ---- +LEDGER INSTALLED 6EFGkt SG I,:; I _ Q <br /> EXTEND 12'BEYOND �' OF THE PENETRATION DE M015TOP OR EQ. FLASHING MATERIAL •ATTACH JAMB STRIPS OF 9'WIDE M015TOP OR EQ <br /> EX BUILDING PAPER IDES c:. I.. a OPENING ( ) <br /> EXPOSED ON ALL 4 SIDES WITH THE 70P EWE EVEN WITH THE TOP OF THE ROUGH SILL. FLASHING MATERIAL WITH INSIDE EDGE EVEN WITH THE JA,`:B Lu <br /> •EXTEND OPENING.THIS STRIP AT LEAST 12'BEYOND THE EDGE OF THE ROUGH OF THE ROUGH OPENING. <br /> DECK LEDGER DETAIL SIDING r1 FLASHING EXTERIOR DOOR FLASHING 1,f PENETRATION PROTECTION ATTACHFLASHING MATERIAL WITH CORROSION-RE515TANT STAPLES ABOVE LOWERSEDGEOF HEADER. <br /> STRIP A"°EXTEND 6' <br /> W22 -- - ._ _ .. - m <br /> 22Y WIG 5CALE I f 5 WI5 SCALE:N.T.S. W t SCALE:N.T.S. <br /> CONT,BEAD OF - <br /> s,oe SEALANT LU <br /> EQ. EQ. FLASHING UNDER NAIL FIN + v <br /> y sco PER PLAN <br /> / OP�I' <PE PANEL J CUT AWAY <br /> '----- E11111,1,D011 -EXCESS WINDOW <br /> LINE OF BLDG.PAPER FRAME ORNERVESTRAL 2x6 HEARTWOODCEDAR TRInBEHIND I IEQ.ALL SIDES,CAULK EAL5'-6°TO HOSE BIB _#•�. I. @OPENING SIMILARI 3't3'LANDING TYP. #NOTE: SEAL ALL --_1 OPENING <br /> 3'6'TO SJDI G�� , BUILDING - v <br /> CL OF NERRVA9RAlT EXPOSED FASTENERS <br /> BUILDING PAPER <br /> PRO14TO FRONT PORCH Of PATIO - <br /> BEND ELECTRICAL 3'-6.LANDING TYP, _ SHEATHING PER PLAN PAPER TYP. <br /> -METER MAIN Q. a BACK PAT IO's scx rerm Ewann eLDG PAPER LINE OF BUILDING PAPER TYP. / <br /> °E pOJRm W 11F 01Ra''x" INSULATION <br /> a nu ram NOE a rue NAIL FLANGE UNDER SILL STRIP <br /> sc.o.wuxevu xes,ne PER PLAN <br /> ® PRONTO BEND ! APPROVED FLASHING - <br /> FRON- INSTALLED ON rooR - 1v6 HEARTWOOD CEDAR TRN1 (0.19 x 10'ROLL) STEP} STEP 4 z <br /> CORNER "-Ems,OF HOUSE TNRFsuolo III LANDING PER PLAN.POUR •APPLY A L3/8'A14 CONTINUOUS BEAD OF CAULK TO THE BACK OF THE FRAME •APPLY THE NEXT COURSE E BUILDING PAPER(BUTTING TO THE <br /> OF HOUSC Al--- ---- I 1,1 uEArzTwcnD ceoAR SIDING PER PLAN I-I/2'GAP NAILING FLANGE AT ALL SIDES Of THE WINDOW FRAME OPENING)OVER THE JAMB(LASHING MATERIAL. <br /> AT GARAGE NOSE :Ua FELT �;'�: -- ------------- TRIn wi FLasuING a BTWN ROOF AND SIDING •PLACE AND SECURE FRAME INTO ROUGH OPENING WITH FLANGES OVER THE •APPLY SUCCEEDING LAYERS OF BUILDING PAPER IN SHINGLE �-r\ <br /> NERVESTRAL HOUSE INTERSECT", ��J <br /> BIB -LANDING PER PLAN �R` INSTALLED JAMB AND SILL{JAMB MOISTOP(OR"c0,)FLASHING MATERIAL. BOARD FASHIIXN UP THE WALL,LAPPING COURSES A MM1IMUM OF Y A <br /> _ (MMIN.a'r3',ttP,) I ROOF SHINGLES •NAIL WINDOWS PER WINDOW MANUFACTURER'S SPECIFICATIONS 1/2 PAPER WIDTH. 1--� <br /> - RGROUNDING - TARTER'. OF STEPS TBD By LINE OF NERVFSTRAL •STARTING FROM THE BASE OF THE WALL,APPLY BUILDING PAPER UNDER <br /> OD INSTALL FROM i.ASHING- \ nuo s1u SITE CONDITIONS , /// 30tt FELT TO EXTEND UP THE SILL STRIP AND CUT ANY EXCE55 BUILDING PAPER THAT MAY EXTEND <br /> PLAN— WALL 12°MIN. <br /> FOR IR 5H o/h4�5WNG A' CONC.WALL SLAB ON GRADE ABOVE THE SILL AND BETWEEN THE JAMBS OF THE OPENING <br /> PRONTO BEND PUTTER PCr � \ •ADD FORTIFLASH STICK FLASHING @BOTH SIDES OF WINDOW <br /> ROOF TRUSS :I Q3°Fa`FRar 0D� •APPLY SLOPED 28 GA.2'BACK,PREFINISHED METAL FLASHING TO OPENING. 1 • i <br /> Af D MOTS fOP.TURN FLAG IN,,,�P um rrea+r Fcaa � ROOF 514EAT14ING PER PLAN •APPLY 6"FORTIFIASH OVER TOP HEAD FLANGE OF WINDOW.EXTEND PAST 1--LJ <br /> q"PIOI <br /> rR1PLAS14 ONTO PANEL, FASCIA PER I JAMB FLASHING 2'. <br /> ZI SIDES 4 CORNERS tW13 EXT. LANDING DETAIL @ ROOF TRU55 -� <br /> 2 TRIM PERIMETER IN F I-,!'I. L''' EAVE W12 SLIDING GLASS DOOR( TYP WII ROOF TO WALL FLASHING WIC STANDARD FLASHING MATERIAL APPLICATION AT OPENINGS <br /> r <br /> n <br /> OPENING rOR ELEC. N.T.S. SCALE:N.T.S. SCALE:N.T.S. <br /> METER BOX,FIREPLACE PAPER�LHII <br /> DIRECT VENT,RANGE VENT, METER EIAIN DRYER VENT,ETC. SEALANT WINDOW FRAME (Y'1 <br /> 3/8'BEAD CAULK INSULATION 7/16"PLYWD.SHEATHING <br /> +SEE DETAIL WID FOR IINSTALL IIITI,A• SILL A55EMBLY �- (WHERE OCCURS) 6'1IFLA5H 0/FLASHING <br /> PER SPEC— <br /> ELECTRIC METER $ HOSE B1t� SEALANT <br /> PER ELEVATION <br /> GYP.BD. ,......, WD.FRAME WALL -SIDING PER PLAN <br /> CW�\I LOCATION (NO GAS METER .- (WHERE APPLICABLE) (WHERE PER PLAN --BUILDING PAPER <br /> ,.I ! NO FOR INSTALL) TRIMMER WD.FRAME WALL BEHALIIND HDR,TN -FOR'INP <br /> 1 GYP BD KING STUD (SEE DETAIL WHO <br /> „�A E N T5. MOISTOP SEE DETAIL BEHIND NOR,TYP @ FOR INSTALL) <br /> / MIN.1/4 GAP BTWN SIDING <br /> SEALANT PER PLAN 18' EXT WALL PER T - FORTIFLASH ON ALL GYP BD AND FLASHING <br /> MOISTOP(SEE - - YCOPTRIGHT NOT¢"':THIS <br /> PLAN SIDES OF WINDOW FLA5NING TURN DOWN RPLAN 15 IOC.E IIOnES.OBBy E PACIFIC <br /> F <br /> DETAIL Will 7/16'PLYWD.SWEA--THING HEADER PER PLAN- I/4'AT EACH END <br /> SIDING PER PLAN FOR INSTALL) _ "Ie PROW By Isw <br /> OF <br /> INSULATION WINDOW FRAME —TRIM PER ELEVATION LICENSE FITWCUT EE TO PACIFIC <br /> 'ER TYP. (WHERE OCCURS) „ SEALANT SEE ELEV.FOR (WHERE APPLICABLE) / <br /> BLDG.PAPER BLDG.PAPER <br /> 10-6'TO 1405E BIB 2 PLAN SIDING PER PLAN WINDOW HT) `\ RIDGE uonEs. <br /> _.. ..._..__. .., ' --_—7/16'PLYWD.SHEATHING SEALANT <br /> TRIM PER ELEVATION _ <br /> 0'-6"TO C.L. - D TRIM (WHERE APPLICABLE) FORTIFLASH ON ALL SEALANT --- WINDOW FRAME PLAN aSUMMARY� r <br /> OF PRONTO BE, <br /> >✓ SIDES OF WINDOW <br /> 7_DK� <br /> SIDING / I ,'I)� �NER N/A <br /> EDGE TQ ED ( q WINDOW SILL @ WOOD FRAME WALLS WINDOW JAMB DETAIL 1WINDOW HEAD DETAIL ��,EDGE LEG7RIUAL \_ ALE 1+T:S, SCALE,N.T.S. SCALE:N.T.S. 5CALE:N.T.S. 506 <br /> flE i"ER MAlll __�R <br /> ® PROWTo BEND - 1075 <br /> FRONT— !N5'ALLED CA orw run v.n, <br /> CORNER %-E,YT.OF HOiiSE LAP SIDING,U.NO.(HOLD I-I/2' ,f' STUDS @ 16'.(NO POSTS/ IBBI <br /> OF HOUSE 1 i OFF ADJOINING ROOF) / , ,/ POINT LOADS ABOVE VENTS) <br /> AT GARAGE - _ LOSE LAG SCREW ( ) SIDING PER PLJR <br /> ,AVF rxu. <br /> --GAS BIBB ATTACHED METAL FLASHING 424 <br /> METER I,;STALL STUDS.LAG MAY BE STEPPED // E. I,- E L BOTTOM SILL P rnr%ww <br /> kOUrICJNG PENETRATE BUILDING PAPER ON �f �'I 3/4'TtG 5UBFLELECTRIC <br /> SHEATHING(SIDING CUT ,j! - FLASHINGJWA <br /> Nr, <br /> -- - - - _ K' TO FR?r: i2/TYP,@ AWAY FOR CLARITY) 1 ice- 7-1/2NIS-1/2'C <br /> ROJiO BcNL - 2!3 NT OF <br /> FURTIFLASH o/FLASHING <br /> METAL RAIN DIVERTER THE AND'I STOP.TURN y <br /> STRAPIM'71bN ( II VENTS w/GALBTL ENGINEERINGFORTIFLASH I'ONTO PANEL, PURPOSE 15 TO SHED THE ( lerv,a+PROVIDE LOUVEA,.L SIDES 6 CORNERS. NWT WATER OFF THE ROOF AND / SEE REVISION LOG <br /> KEEP IT AWAY FROM THE / ROOF 94CLES @FRONT ELEVAFLASI I \ -RIM PER PLAN2.2 TRIM @ PERIMETER I, VERTICAL WALL BENEATH). / PER SPEC.Y -P.T.MUD SILL SCALE:Y = I'-O' <br /> OPENING FOR ELEC. - _ I ',.,_U.: OF HOOT FASCIA PER PLAN w/ / 300 ROOF FELT �—CONCRETE FOUNDATION J wRNuls <br /> METER BOX,FIREPLACE A[I:9EHINLG GUTTER / / +tDO NOT INSTALL VENT(5)CLOSER THAN 3'TO GAS METER++ <br /> DIRECT VENT, RANGE VENT, > / METER r,A111 /� �/ 7/I6'OSB ROOF WATER <br /> SHEATHING x+BUILDING PAPER SHOULD BE INSTALLED OVER FLASHING++ <br /> DRYER VENT, ETC. /� INTRUSION <br /> _ r SEE DETAIL WIO FOR M01570P INSTALL NSTRUCTo.irb L- �` NOTE:PER W5EC R402.2.7:WHEN FOUNDATION VENTS ARE NOT PLACED 50 THAT THE TOP DETAILS <br /> _ OF THE VENT 15 BELOW THE LOWER SURFACE OF THE FLOOR INSULATION,A PERMANENTLY <br /> E. SEAL ALL <br /> ELECTRIC GAS METER HOJ- �- ATTACHED BAFFLE SHALL BE INSTALLED AT AN ANGLE OF 30'FROM HORIZONTAL,TO <br /> USE 3 STRAPS ON 75 GALLON AND GREATER SIZES EXPOSED FASTENERS DIVERT AIR FLOW BELOW THE LONER SURFACE OF THE FLOOR INSULATION. <br /> BIB CLEARANCES LOCATIOrjS �IATER NEATER (NWT) STRAPS @ DETAIL @ ROOF/WALL INTERSECTION ` vI /FOUNDATION VENT 1 0 <br /> W5 f 5CALE:N.T.S. KALE:N.T.S. vVL SCALE:N.T.S. �V� SCALE:N.T.S. <br />