SLIDING CLASS DOOR
<br /> SELF ADHESIVE --- _-` __ ---PER PLAN -
<br /> MEMBRANE PA,N SLIDING GLASS DOOR EXTEND MIN.6'UP JAMB -
<br /> FLASHING-----,\ / NAIL FL"IJGE - -
<br /> NAIL ON FLEXIBLE \ GALV /.'FLASHING NERVASTRAL TO EXTEND
<br /> FLOOR JO°T \ �—L MIN FROM TOP OF OF THE DOOR \ HEADER/ \ HEADER/
<br /> PER PLAN / SEHER TO LAG EGAk GECKINGW 2'PAST THE INTERIOR
<br /> FLASHING -
<br /> I., BARRIER ...._... / ROUGH ROUGH
<br /> - -- / PER P IJ WATER RF l LE OPENING OPENING
<br /> w U
<br /> ^,.PTOI_`f PER PLAN \ JAMB\ JAMB\
<br /> HANGER PER PLAID JOINT FLASHING-- - __. `2ND plECf / SILL \ / SILL \
<br /> INSTALL PLANKS I.
<br /> _�� IN MODERATE PENETRATION �• �
<br /> RIM JOIST < -. P"i LEDGER PER F_AN CONI"AC -_-. / -__� lS7 p! 'i I II
<br /> BUILDING PAPER— _ fCF, - SILL
<br /> -SHEATHING PER PLAN - 12,
<br /> INSTALLED BEHIND " _.._,__ '\ BUILDING PAPER TO EXTEND �, ,___;_, FLASHING -
<br /> SIDING PER. I
<br /> LEDGER AND PAN ---SIDING PER PLAN PLAN Q
<br /> FLASHING.LAP MIN.12"BEYOND ALL EDGES
<br /> OVER HOUSE WRAP F LEDGER INSTALLED BEFORE 51DIId` '� STEP I STEP 2
<br /> J i. EXTEND 12'BEYOND - OF THE PENETRATION r , 1
<br /> w/BUILDING PAPER BEHIND IT w/6" •ATTACH SILL STRIP OF 9"WIDE T14E T P(OR HE FLASHING MATERIAL •ATTACH JAMB STRIPS OF IN WIDE EDGE
<br /> EVE(OR E0 H L u
<br /> EXPOSED ON ALL 4 SIDESOPENING WITH THE TOP EDGE EVEN WITH THE TOP OF THE ROUGH SILL. FLASHING MATERIAL WITH INSIDE EDGE EVEN WITH THE JAMB
<br /> •EXTEND THIS STRIP AT LEAST 12'BEYOND THE EDGE OF THE ROUGH OF THE ROUGH OPENING. a
<br /> OPENING. •START JAMB STRIPS 2'BELOW SILL STRIP AND EXTEND 6"
<br /> DECK LEDGER DETAIL SIDING BUTT .Ic: FLASHING EXTERIOR DOOR FLASHING PENETRATION PROTECTION ATTACH FLASHING MATERIAL WITH CORROSION-RESISTANT STAPLE'S. ABOVE LOWER EDGE OF HEADER. V
<br /> __...---__.-._ (W16 SCALE a Ts - -- SCALE:N.T.S. SCALE:N.T.S. ^/
<br /> / 1 ' '
<br /> cFN+u Tnn � °X CONT.BEAD OF L--1 r \
<br /> SEALANT
<br /> EG1. F EO, iI FLASHING UNDER NAIL FIN 2" 2°
<br /> ^, SGD PER PLAN ■ n/T AWAY <
<br /> / BENIND l .-PANEL _I PEED.uJ.sIDEs,uuxK/sEnl. SIMILAR .__ ®LAW OPENING r�NDOh 4-L LU
<br /> OPERABLE FIXED
<br /> _ WINDOW EXCESS NI 1 1 1
<br /> /,.... NERVESTRAL LINE ---------- I ?Ai HEARTWOOD CEDAR TRIM, I FRAME OR BLDG.PAPER M LARR Q u-i
<br /> �� OPENING J OPENING �� J 5 6" of —-_-_ ERG- ,IERvuTRAL EXPOSED FASTENERS I�' BUILDING TO HOSE BIB EQ. 1tr'E E0.
<br /> 6"TO
<br /> SIDING , RUNDITTTP. ENO SEAL ALL
<br /> C L BUILDING PAPER
<br /> PRONTO FRONT PORCH PATIO SHEATHING PER PLAN PAPER TYP.
<br /> _ _ELECTRICAL 3'-b'LANDING TYP,
<br /> imi
<br /> u.s LINE OF BUILDING PAPER
<br /> TYP.
<br /> 'x" INSULATION
<br /> � METER MAIN P BACK PATIO's BLDG PAPER
<br /> TIENAIL FLANGE UNDER SILL STRIP
<br /> PRONTO BEND lnE PER PLAN
<br /> ® APPROVED FLASHING /
<br /> INSTALLED ON DXR -M- &6 NEARTWWD CEDAR TRIM (0.19 x 10'ROLL) STEP 3 STEP qCORNER -- - LANDING PER PUN FOUR .APPLY A 3/8'CONTINUOUS BEAD OF CAULK TO THE BACK OF THE FRAME •APPLY THE NEXT COURSE OF BUILDING PAPER BUTTING TO THE
<br /> 0"r FO'JSF EXL.OF HOUSE THRESHOLD AGAINST NBRVESTRAL ns uEARTwcoO CEDAR SIDING PER PLAN I-I/2'GAP NAILING FLANGE AT ALL SIDES OF THE WINDOW FRAME OPENING)OVER THE JAMB FLASHING MATERIAL, �—)
<br /> J0#FELT 4+ -- --.----------NEUNE
<br /> 1RIn�'/FLASHING a BTWN ROOF AND SIDING •PLACE AND SECURE FRAME INTO RWGH OPENING WITH FLANGES OVER THE •APPLY SUCCEEDING LAYERS OF BUILDING PAPER IN SHINGLE
<br /> AT?..��/?':,F NOSE NERVESTRAL HLUSE INTERSECTION,
<br /> BIBS -�D�PER P� MERE OCCURS INSTALLED JAMB AND SILL I JAMB M015TOP(OR E0.)FLASHING MATERIAL. BOARD FASWON UP THE WALL,LAPPING COURSES A MINIMUM OFINSTALL STARTER. <F (MIN Td TYP) ROOF SHINGLES •NAIL WINDOWS PER WINDOW MANUFACTURER'S SPECIFICATIONS I/2 PAPER WIDTHV FLASHING51oPSTEPs TBD BY OF NERVESTRu STARTING FROM THE BASE OF THE WALL,APPLY BUILDING PAPER UNDER
<br /> GRO ND - nu0 5aL SITEwaorcwNs 30>t FELT TO EXTEND UP THE SILL STRIP AND CUT ANY EXCESS BUILDING PAPER THAT MAY EXTEND
<br /> qPLANER-'- ,-� WALL 12'MIN,5UB ON GRAD ABOVE THE SILL AND BETWEEN THE JAMBS OF THE OPENING.
<br /> TURN
<br /> FOR]MFL STOP FLASHING iIOh O \ ADD FORTIFLASH STICK FLASHING BOTH SIDES OF WINDOW
<br /> PRONTO BEND � I
<br /> ROD 12'rRGI'1 _ I, _
<br /> y y
<br /> ANDrc " III ROOF TRU55 EXT. LANDING DE see Hx FB'"i mx •APPLY SLOPED 25 SH V BACK,PREF14EAD FLANGISHEDE
<br /> METAL FLASHING TO OPENING.
<br /> - ar Fw�n rrnc uruL -ROOF SHEATHING PER PLAN •APPLY 6"FORTIFLASH OVER TOP HEAD FLANGE OF WINDOW.EXTEND PAST
<br /> FORTIFLASHI'ONTO PANEL, FASCIA PEN f �zd TAIL @ H ROOF TRUSS
<br /> JAMB FLASHING 2"
<br /> ALL SIDES E CORNERS. E p
<br /> 2x2 TRIPI 0 PERIMEI ER T F I- ,w,Ljl- '��. � - @ EAVE SLIDING GLASS DOOR TYP ROOF TO WALL FLASHING STANDARD FLASHING MATERIAL APPLICATION AT OPENINGS
<br /> : . � . ��_
<br /> OPENING FOR ELEC. <: `IIN BLDG DWI3 W12 SCALE:N.T.S. WII SCALE:N.T.S. VVIO SCALE:N.T.S. lJ J
<br /> -
<br /> METER BOX,FIREPLACE _.__.__. PAPER BEHIND
<br /> 'DIRECT VENT, RANGE VENT, ' I'.E IR fI EAIEJ
<br /> DRYER VENT, ETC.
<br /> SEAT WINDOW FRAME
<br /> INSULATION ---- 7/16'PLYWD.SHEATHING �\
<br /> +SEE DE7AIL WIO FOR MOISTOP INSTALL IIJS ERUCTIGrIS SILL ASSEMBLY 3/8"BEAD CAULK
<br /> M PER SPEC ��SEALANT (WHERE OCCURS) 6"FORTIFLASH 0/FLASHING E \
<br /> ELECTRIC IETER $ HOSE BIB TRIM PER ELEVATION GYP.BD. IND.FRAME WALL SIDING PER PLAN _\_l
<br /> �? �.-I PER PLAN
<br /> C�LOCATION NO GAS METER) (WHERE APPLICABLE) - INSULATION -BUILDING PAPER
<br /> TRIMMER (WHERE OCCUR5) R-10 INSULATION MOISTOP(SEE DETAIL WIIO
<br /> SCALE:N.T.S,
<br /> GYP BD W10 FOR
<br /> (SEE DETAIL BEHIND S TYP 6 FOR INSTALL)
<br /> KING STUD
<br /> WIO FOR INSTALL) WD,FRAME WALL ALL HDR's
<br /> MIN,I/4'GAP BTWN SIDING
<br /> SEALANT PER PLAN r AND FLASHING ul"YRIGHT NOTICE.TA5
<br /> MIN.IV EXT WALL PER GYP.BD.
<br /> 1 - FORTIFLA54 ON ALL MOISTOP(SEE Pi IN 15PLAN IFSIDES OF WINDOW - `-FLASHING TURN DOWN R LGE HOMES.USE OF PACIFIC
<br /> DETAIL WIO ,_ HEADER PER PLAN- ---- Pl.:w 15 PROHIBITED BY Uri
<br /> j J 7/Ib'PLYWD.SHEATHING I/4"AT EACH END
<br /> _ SIDING PER PLAN FOR INSTALL) wIINwT PAmENi OF
<br /> ' TRIM PER ELEVATION a ENSE FEE To PACIFIC
<br /> INSULATION WINDOW FRAME RIDGE HOMES
<br /> �- BLDG.PAPER BLDG.PAPER 5EE ELEV.FOR (WHERE APPLICABLE)
<br /> j .PER TYP. (WHERE OCCURS) SEALANT SIDING PER PLAN WINDOW HT)
<br /> 10'-b"TO HOSE BIB 'R PLAN --7/16'PLTWD.SHEATHING TRIM PER ELEVATION ,SEALANT PLAN SUMMARY
<br /> — -
<br /> W-6"TO C.L. I ED TRIM FORTIFLASH ON ALL _� Iaa a:"s asxsaFx FT..
<br /> (WHERE APPLICABLE) SEALANT NiA
<br /> OF PRONTO BEND SIDES OF WINDOW -WINDOW FRAME
<br /> EDGE TOEDGE rO S I D N )RNER WINDOW SILL @ WOOD FRAME WALL WINDOW JAMB DETAIL WINDOW HEAD DETAIL ^H n^
<br /> EDGE EDGE _ ELECTRICAL I�W� SCALE N.0 SCALE:
<br /> S. WV SCALE:N.T.S. W� SCALE:N.T.S. W� BEiI
<br /> X IETER MAD: N.T.S.
<br /> uA sa Fr..
<br /> 1251
<br /> e F30NTO E,Y,:
<br /> FR,N] - �51AUED a. T2102 ten.
<br /> CORNER STUDS P I6'a(NO POSTS/
<br /> L'' OF IOU,.: LAP SIDING, UAO.(HOLD 1-1/2' _
<br /> _ �' / POINT LOADS ABOVE VENTS)OF HOUSE /
<br /> AT GARAGE GCSE OFF ADJOINING ROOF) ZO
<br /> LAG SCREW SIDING PER PLAN _
<br /> x
<br /> fW' BIBB Ii Y ATTACHED METAL FLASHING i
<br /> --GAS MAY BE STEPPED 6 E0. E0. BOTTOM SILL PLATE
<br /> METER -NSTALL STUDS.LAG ( ) '�I- E!.ECTRIC
<br /> GROUNDING PENETRATE BUILDING PAPER ON -3/4"TIC,SUBFLOOR "AnIIn uu�nw rmnxaa.
<br /> ROD 12 FR01' 11N.,TYP.P SHEATHING(SIDING GUT �-: � i'i i'i FLASHING JWA
<br /> 'RIXJ70 BEND >4 HT W
<br /> AWAY FOR CLARITY)
<br /> FORTIFLASH o/FLASHING ACH w/I I : BTL ENGINEERING
<br /> AND M015TOP.TURN- ° �1015 TOP .STRAP MIN METAL RAIN DIVERTER(THE I 7-ENTS 1,,/G CEDAR RIM Lw
<br /> w II iI VENTS w/GALV SCREEN-
<br /> FOkTIFLASH I"ONTO PANEL, PURPOSE IS TO SHED THE PROVIDE LOUVERED VENTS "L^'
<br /> ALL SIDES 4 CORNERS. T W WATER OFF THE ROOF AND % P'FRONT ELEVATIONS BI°E REVISION LOG
<br /> KEEP IT AWAY FROM THE ,.� ROOF SHINGLES RIM PER PLAN--' •"Y'"f 0"A
<br /> -R.A>FHNG % "
<br /> E
<br /> VERTICAL WALL BENEATH. % PER SPEC, \— SCALE:Y" -0
<br /> 2x2 TRIM r PERIMETER �i rP ) ,,� /%� �P.T.MUD SILL
<br /> UPENiNG FOR ELEC.-- -,ti 60 IIrJ BLOC. T W NWT FASCIA PER PLAN w/ % /ice 30k ROOF FELT CONCRETE FOUNDATION
<br /> ]��
<br /> METER BOX, FIREPLACE PAPER 6 LOC. GUTTER S upp NOT INSTALL VENT 5 CLOSER THAN 3'TO GAS METER++ WATER
<br /> uRECT VENT,RANGE VENT, METER MAID. / 7/I6'OSB ROOF ()
<br /> DRYER VENT,ETC. SHEATHING 4+BUILDING PAPER SHOULD BE INSTALLED OVER FLASNING0 INTRUSION
<br /> % \��•�
<br /> +SEE DETAIL WIO FOR M015TOP INSTALL INS,RUCT ICNS ,/ �.,` NOTE:PER WSEC R402.2.7:WHEN FOUNDATION VENTS ARE NOT PLACED 50 THAT THE TOP DETAILS
<br /> - +NOTES SEAL ALL OF THE VENT 15 BELOW THE LOWER SURFACE OF THE FLOOR INSULATION,A PERMANENTLY sn'
<br /> ELECTRIC GAS METER,
<br /> IETER HOSE ATTACHED BAFFLE SHALL BE INSTALLED AT AN ANGLE OF 3CY FROM HORIZONTAL,TO
<br /> USE 3 STRAPS ON 75 GALLON AND GREATER SIZES EXPOSED FASTENERS DIVERT AIR FLOW BELOW THE LOWER SURFACE OF THE FLOOR INSULATION..
<br /> W5 BIB CLEARANCES t LOCATIONS_ WATER HEATER (HWT) STRAPS DETAIL @ ROOF/WALL INTERSECTION yl1 FOUNDATION VENT
<br /> .T.S. � 1 SCALE:H.T.S. SCALE:N.T.S. SCALE:N SCALE:N.T.S.
<br />
|