Laserfiche WebLink
SLIDING CLASS DOOR <br /> SELF ADHESIVE --- _-` __ ---PER PLAN - <br /> MEMBRANE PA,N SLIDING GLASS DOOR EXTEND MIN.6'UP JAMB - <br /> FLASHING-----,\ / NAIL FL"IJGE - - <br /> NAIL ON FLEXIBLE \ GALV /.'FLASHING NERVASTRAL TO EXTEND <br /> FLOOR JO°T \ �—L MIN FROM TOP OF OF THE DOOR \ HEADER/ \ HEADER/ <br /> PER PLAN / SEHER TO LAG EGAk GECKINGW 2'PAST THE INTERIOR <br /> FLASHING - <br /> I., BARRIER ...._... / ROUGH ROUGH <br /> - -- / PER P IJ WATER RF l LE OPENING OPENING <br /> w U <br /> ^,.PTOI_`f PER PLAN \ JAMB\ JAMB\ <br /> HANGER PER PLAID JOINT FLASHING-- - __. `2ND plECf / SILL \ / SILL \ <br /> INSTALL PLANKS I. <br /> _�� IN MODERATE PENETRATION �• � <br /> RIM JOIST < -. P"i LEDGER PER F_AN CONI"AC -_-. / -__� lS7 p! 'i I II <br /> BUILDING PAPER— _ fCF, - SILL <br /> -SHEATHING PER PLAN - 12, <br /> INSTALLED BEHIND " _.._,__ '\ BUILDING PAPER TO EXTEND �, ,___;_, FLASHING - <br /> SIDING PER. I <br /> LEDGER AND PAN ---SIDING PER PLAN PLAN Q <br /> FLASHING.LAP MIN.12"BEYOND ALL EDGES <br /> OVER HOUSE WRAP F LEDGER INSTALLED BEFORE 51DIId` '� STEP I STEP 2 <br /> J i. EXTEND 12'BEYOND - OF THE PENETRATION r , 1 <br /> w/BUILDING PAPER BEHIND IT w/6" •ATTACH SILL STRIP OF 9"WIDE T14E T P(OR HE FLASHING MATERIAL •ATTACH JAMB STRIPS OF IN WIDE EDGE <br /> EVE(OR E0 H L u <br /> EXPOSED ON ALL 4 SIDESOPENING WITH THE TOP EDGE EVEN WITH THE TOP OF THE ROUGH SILL. FLASHING MATERIAL WITH INSIDE EDGE EVEN WITH THE JAMB <br /> •EXTEND THIS STRIP AT LEAST 12'BEYOND THE EDGE OF THE ROUGH OF THE ROUGH OPENING. a <br /> OPENING. •START JAMB STRIPS 2'BELOW SILL STRIP AND EXTEND 6" <br /> DECK LEDGER DETAIL SIDING BUTT .Ic: FLASHING EXTERIOR DOOR FLASHING PENETRATION PROTECTION ATTACH FLASHING MATERIAL WITH CORROSION-RESISTANT STAPLE'S. ABOVE LOWER EDGE OF HEADER. V <br /> __...---__.-._ (W16 SCALE a Ts - -- SCALE:N.T.S. SCALE:N.T.S. ^/ <br /> / 1 ' ' <br /> cFN+u Tnn � °X CONT.BEAD OF L--1 r \ <br /> SEALANT <br /> EG1. F EO, iI FLASHING UNDER NAIL FIN 2" 2° <br /> ^, SGD PER PLAN ■ n/T AWAY < <br /> / BENIND l .-PANEL _I PEED.uJ.sIDEs,uuxK/sEnl. SIMILAR .__ ®LAW OPENING r�NDOh 4-L LU <br /> OPERABLE FIXED <br /> _ WINDOW EXCESS NI 1 1 1 <br /> /,.... NERVESTRAL LINE ---------- I ?Ai HEARTWOOD CEDAR TRIM, I FRAME OR BLDG.PAPER M LARR Q u-i <br /> �� OPENING J OPENING �� J 5 6" of —-_-_ ERG- ,IERvuTRAL EXPOSED FASTENERS I�' BUILDING TO HOSE BIB EQ. 1tr'E E0. <br /> 6"TO <br /> SIDING , RUNDITTTP. ENO SEAL ALL <br /> C L BUILDING PAPER <br /> PRONTO FRONT PORCH PATIO SHEATHING PER PLAN PAPER TYP. <br /> _ _ELECTRICAL 3'-b'LANDING TYP, <br /> imi <br /> u.s LINE OF BUILDING PAPER <br /> TYP. <br /> 'x" INSULATION <br /> � METER MAIN P BACK PATIO's BLDG PAPER <br /> TIENAIL FLANGE UNDER SILL STRIP <br /> PRONTO BEND lnE PER PLAN <br /> ® APPROVED FLASHING / <br /> INSTALLED ON DXR -M- &6 NEARTWWD CEDAR TRIM (0.19 x 10'ROLL) STEP 3 STEP qCORNER -- - LANDING PER PUN FOUR .APPLY A 3/8'CONTINUOUS BEAD OF CAULK TO THE BACK OF THE FRAME •APPLY THE NEXT COURSE OF BUILDING PAPER BUTTING TO THE <br /> 0"r FO'JSF EXL.OF HOUSE THRESHOLD AGAINST NBRVESTRAL ns uEARTwcoO CEDAR SIDING PER PLAN I-I/2'GAP NAILING FLANGE AT ALL SIDES OF THE WINDOW FRAME OPENING)OVER THE JAMB FLASHING MATERIAL, �—) <br /> J0#FELT 4+ -- --.----------NEUNE <br /> 1RIn�'/FLASHING a BTWN ROOF AND SIDING •PLACE AND SECURE FRAME INTO RWGH OPENING WITH FLANGES OVER THE •APPLY SUCCEEDING LAYERS OF BUILDING PAPER IN SHINGLE <br /> AT?..��/?':,F NOSE NERVESTRAL HLUSE INTERSECTION, <br /> BIBS -�D�PER P� MERE OCCURS INSTALLED JAMB AND SILL I JAMB M015TOP(OR E0.)FLASHING MATERIAL. BOARD FASWON UP THE WALL,LAPPING COURSES A MINIMUM OFINSTALL STARTER. <F (MIN Td TYP) ROOF SHINGLES •NAIL WINDOWS PER WINDOW MANUFACTURER'S SPECIFICATIONS I/2 PAPER WIDTHV FLASHING51oPSTEPs TBD BY OF NERVESTRu STARTING FROM THE BASE OF THE WALL,APPLY BUILDING PAPER UNDER <br /> GRO ND - nu0 5aL SITEwaorcwNs 30>t FELT TO EXTEND UP THE SILL STRIP AND CUT ANY EXCESS BUILDING PAPER THAT MAY EXTEND <br /> qPLANER-'- ,-� WALL 12'MIN,5UB ON GRAD ABOVE THE SILL AND BETWEEN THE JAMBS OF THE OPENING. <br /> TURN <br /> FOR]MFL STOP FLASHING iIOh O \ ADD FORTIFLASH STICK FLASHING BOTH SIDES OF WINDOW <br /> PRONTO BEND � I <br /> ROD 12'rRGI'1 _ I, _ <br /> y y <br /> ANDrc " III ROOF TRU55 EXT. LANDING DE see Hx FB'"i mx •APPLY SLOPED 25 SH V BACK,PREF14EAD FLANGISHEDE <br /> METAL FLASHING TO OPENING. <br /> - ar Fw�n rrnc uruL -ROOF SHEATHING PER PLAN •APPLY 6"FORTIFLASH OVER TOP HEAD FLANGE OF WINDOW.EXTEND PAST <br /> FORTIFLASHI'ONTO PANEL, FASCIA PEN f �zd TAIL @ H ROOF TRUSS <br /> JAMB FLASHING 2" <br /> ALL SIDES E CORNERS. E p <br /> 2x2 TRIPI 0 PERIMEI ER T F I- ,w,Ljl- '��. � - @ EAVE SLIDING GLASS DOOR TYP ROOF TO WALL FLASHING STANDARD FLASHING MATERIAL APPLICATION AT OPENINGS <br /> : . � . ��_ <br /> OPENING FOR ELEC. <: `IIN BLDG DWI3 W12 SCALE:N.T.S. WII SCALE:N.T.S. VVIO SCALE:N.T.S. lJ J <br /> - <br /> METER BOX,FIREPLACE _.__.__. PAPER BEHIND <br /> 'DIRECT VENT, RANGE VENT, ' I'.E IR fI EAIEJ <br /> DRYER VENT, ETC. <br /> SEAT WINDOW FRAME <br /> INSULATION ---- 7/16'PLYWD.SHEATHING �\ <br /> +SEE DE7AIL WIO FOR MOISTOP INSTALL IIJS ERUCTIGrIS SILL ASSEMBLY 3/8"BEAD CAULK <br /> M PER SPEC ��SEALANT (WHERE OCCURS) 6"FORTIFLASH 0/FLASHING E \ <br /> ELECTRIC IETER $ HOSE BIB TRIM PER ELEVATION GYP.BD. IND.FRAME WALL SIDING PER PLAN _\_l <br /> �? �.-I PER PLAN <br /> C�LOCATION NO GAS METER) (WHERE APPLICABLE) - INSULATION -BUILDING PAPER <br /> TRIMMER (WHERE OCCUR5) R-10 INSULATION MOISTOP(SEE DETAIL WIIO <br /> SCALE:N.T.S, <br /> GYP BD W10 FOR <br /> (SEE DETAIL BEHIND S TYP 6 FOR INSTALL) <br /> KING STUD <br /> WIO FOR INSTALL) WD,FRAME WALL ALL HDR's <br /> MIN,I/4'GAP BTWN SIDING <br /> SEALANT PER PLAN r AND FLASHING ul"YRIGHT NOTICE.TA5 <br /> MIN.IV EXT WALL PER GYP.BD. <br /> 1 - FORTIFLA54 ON ALL MOISTOP(SEE Pi IN 15PLAN IFSIDES OF WINDOW - `-FLASHING TURN DOWN R LGE HOMES.USE OF PACIFIC <br /> DETAIL WIO ,_ HEADER PER PLAN- ---- Pl.:w 15 PROHIBITED BY Uri <br /> j J 7/Ib'PLYWD.SHEATHING I/4"AT EACH END <br /> _ SIDING PER PLAN FOR INSTALL) wIINwT PAmENi OF <br /> ' TRIM PER ELEVATION a ENSE FEE To PACIFIC <br /> INSULATION WINDOW FRAME RIDGE HOMES <br /> �- BLDG.PAPER BLDG.PAPER 5EE ELEV.FOR (WHERE APPLICABLE) <br /> j .PER TYP. (WHERE OCCURS) SEALANT SIDING PER PLAN WINDOW HT) <br /> 10'-b"TO HOSE BIB 'R PLAN --7/16'PLTWD.SHEATHING TRIM PER ELEVATION ,SEALANT PLAN SUMMARY <br /> — - <br /> W-6"TO C.L. I ED TRIM FORTIFLASH ON ALL _� Iaa a:"s asxsaFx FT.. <br /> (WHERE APPLICABLE) SEALANT NiA <br /> OF PRONTO BEND SIDES OF WINDOW -WINDOW FRAME <br /> EDGE TOEDGE rO S I D N )RNER WINDOW SILL @ WOOD FRAME WALL WINDOW JAMB DETAIL WINDOW HEAD DETAIL ^H n^ <br /> EDGE EDGE _ ELECTRICAL I�W� SCALE N.0 SCALE: <br /> S. WV SCALE:N.T.S. W� SCALE:N.T.S. W� BEiI <br /> X IETER MAD: N.T.S. <br /> uA sa Fr.. <br /> 1251 <br /> e F30NTO E,Y,: <br /> FR,N] - �51AUED a. T2102 ten. <br /> CORNER STUDS P I6'a(NO POSTS/ <br /> L'' OF IOU,.: LAP SIDING, UAO.(HOLD 1-1/2' _ <br /> _ �' / POINT LOADS ABOVE VENTS)OF HOUSE / <br /> AT GARAGE GCSE OFF ADJOINING ROOF) ZO <br /> LAG SCREW SIDING PER PLAN _ <br /> x <br /> fW' BIBB Ii Y ATTACHED METAL FLASHING i <br /> --GAS MAY BE STEPPED 6 E0. E0. BOTTOM SILL PLATE <br /> METER -NSTALL STUDS.LAG ( ) '�I- E!.ECTRIC <br /> GROUNDING PENETRATE BUILDING PAPER ON -3/4"TIC,SUBFLOOR "AnIIn uu�nw rmnxaa. <br /> ROD 12 FR01' 11N.,TYP.P SHEATHING(SIDING GUT �-: � i'i i'i FLASHING JWA <br /> 'RIXJ70 BEND >4 HT W <br /> AWAY FOR CLARITY) <br /> FORTIFLASH o/FLASHING ACH w/I I : BTL ENGINEERING <br /> AND M015TOP.TURN- ° �1015 TOP .STRAP MIN METAL RAIN DIVERTER(THE I 7-ENTS 1,,/G CEDAR RIM Lw <br /> w II iI VENTS w/GALV SCREEN- <br /> FOkTIFLASH I"ONTO PANEL, PURPOSE IS TO SHED THE PROVIDE LOUVERED VENTS "L^' <br /> ALL SIDES 4 CORNERS. T W WATER OFF THE ROOF AND % P'FRONT ELEVATIONS BI°E REVISION LOG <br /> KEEP IT AWAY FROM THE ,.� ROOF SHINGLES RIM PER PLAN--' •"Y'"f 0"A <br /> -R.A>FHNG % " <br /> E <br /> VERTICAL WALL BENEATH. % PER SPEC, \— SCALE:Y" -0 <br /> 2x2 TRIM r PERIMETER �i rP ) ,,� /%� �P.T.MUD SILL <br /> UPENiNG FOR ELEC.-- -,ti 60 IIrJ BLOC. T W NWT FASCIA PER PLAN w/ % /ice 30k ROOF FELT CONCRETE FOUNDATION <br /> ]�� <br /> METER BOX, FIREPLACE PAPER 6 LOC. GUTTER S upp NOT INSTALL VENT 5 CLOSER THAN 3'TO GAS METER++ WATER <br /> uRECT VENT,RANGE VENT, METER MAID. / 7/I6'OSB ROOF () <br /> DRYER VENT,ETC. SHEATHING 4+BUILDING PAPER SHOULD BE INSTALLED OVER FLASNING0 INTRUSION <br /> % \��•� <br /> +SEE DETAIL WIO FOR M015TOP INSTALL INS,RUCT ICNS ,/ �.,` NOTE:PER WSEC R402.2.7:WHEN FOUNDATION VENTS ARE NOT PLACED 50 THAT THE TOP DETAILS <br /> - +NOTES SEAL ALL OF THE VENT 15 BELOW THE LOWER SURFACE OF THE FLOOR INSULATION,A PERMANENTLY sn' <br /> ELECTRIC GAS METER, <br /> IETER HOSE ATTACHED BAFFLE SHALL BE INSTALLED AT AN ANGLE OF 3CY FROM HORIZONTAL,TO <br /> USE 3 STRAPS ON 75 GALLON AND GREATER SIZES EXPOSED FASTENERS DIVERT AIR FLOW BELOW THE LOWER SURFACE OF THE FLOOR INSULATION.. <br /> W5 BIB CLEARANCES t LOCATIONS_ WATER HEATER (HWT) STRAPS DETAIL @ ROOF/WALL INTERSECTION yl1 FOUNDATION VENT <br /> .T.S. � 1 SCALE:H.T.S. SCALE:N.T.S. SCALE:N SCALE:N.T.S. <br />