Laserfiche WebLink
FLOOR PLAN NOTES <br /> (ENTER,.I11 e <br /> aPERAB� <br /> I. CONTRACTOR SHALL VERIFY ALL NOTES,MATERIALS t CONDITIONS PRIOR TO soFa <br /> CONSTRUCTION. EQ -- <br /> SGD PER PLAN DOOR t JAMB <br /> WINDOWS It DOORS: aERAB e FIXED <br /> 2. ALL EXTERIOR WINDOW t DOOR HEADERS TO BE INSULATED w/R-10 INSJThs`I PANEL PANEL CAULK BACK OF <br /> _ THRESHOLD TO WRAP NERVASTRAL <br /> 3. WINDOWS t DOORS ARE SHOWN t NOTED AS NOMINAL SIZES. or.or - -.---- NERVESTRAL UP JAMB 6" <br /> 4. WINDOW HEAD HEIGHT R.O.SHOWN PER ELEVATIONS. EGRESS WINDOk SN.. 'ICI,I R.0 C° JD 1 2b HEARTWOOD CEDAR rwM, <br /> TRALI EO.ALL SIDES,uuuvsEa. t ALL SEAMS (A fie"BEADS OF <br /> MAX. O A.F.F. - EQ. CAULK UNDER <br /> 5. ALL WOOD IN CONTACT WITH CONC.TO BE PRESSURE TREATED. IXT� I I 3'e3'LANDING TTP. <br /> IG EQ ,; PAR AGAINST _-: -. NERVESTRAL,(1) <br /> 6. EXTERIOR WALLS TO BE 2x6 STUDS @ Ib"O.C.,U.NO. ' - I NERVASTRAL Wes,EDGE` @ SIDES OF JAMB _,.. <br /> 7. GARAGE DOOR HEADERS @&{°A.F.F. FRaN,1'PCRLFI parlo THRESHOLD w/ 30'-0° <br /> 8. EXTERIOR SWING DOOR HEADERS @ 83 112'A,F A.F.F. 3'-6'LANDING TYP. yuK PATn>wwL° ADD'L NERVASTRAL NERVASTRAL OR EQ - <br /> 10 INTERIOR SWING DOOR HEADERS @ 83'A.F.F. P BACK PATIO'S °fR 1N 1M°O1m°T"" THRESHOLD DETAIL 17-0' 13'-0" <br /> 10, SWING DOORS TO FOLLOW CENTERLINE DIMENSION IN PLANS t�2 Bt n.;d. 4 NGt SIDE, a n¢Flxm sloe aF Tue <br /> ,A.a. eR asses Dq <br /> H. GARAGE-TO-HOUSE DOOR TO BE A SOLID HOOD IV THICK 20 MINUTE Hk k T CD DOOR 2x6 HEARTWWD CEDAR TRIM SCALE: 1-1/2' P-0' 1T-0' S'-0' q'-0' <br /> w/A SELF CLOSING HARDWARE DEVICE, m LANDNG PER PLAN.FouR - <br /> 12. PER R311.3.1:THE LANDING OR FLOOR ON THE EXTERIOR SIDE 01 I hKIJK..COBS IREsuaD "" AGarING PER PLAN.L 2xc uEaRTwaoD CEDAR <br /> EXCEPT THE FRONT DOOR SHALL BE NOT MORE THAN 7-3/4"BEL I He"(, U ?HE --- TRIM./FI.A5HING @ 5-1CXi' 2A'x36"HEAT (�THRESHOLD PROVIDED THE DOLOR DOES NOT SHING OVER THE LANI.riG C:< L CR KERVESTRAL I "SE INTERSECTION, PUMP BASE. <br /> 13. ALL BI-FOLD t BI-PASS DOORS TO BE CENTERED,U.N.O. LANDING PER PLAN '_ _ MERE accuRs W1- WHEN GARAGE w <br /> ..(MIN 3F3',TTp.) I <br /> OF STEPS TBD BT ; uNE OF NERVESTRAL 4O (� OPT.SELECTED, <br /> FRAMING ID SILL SITE COlanoxs VERIFY LOCATION <br /> 3'xL CONC. SITE SUPER <br /> 14. VERIFI FIREPLACE STYLE t LOCATION w/SUPERVISOR PRIOR Tv CUNSI wALL 5LAB ON GRADE -,I LANDING Oy-Y <br /> 15. FRAMEkS TO INSTAL!ALL WINDOWS t INTERIOR COLUMNS 5040 XO t-1--!I6. TONE!RINGBAR BL'G049' A.F.F. EXT. LANDING DE sEe wd FaR Fmrt am Q : - _- _._ .. - <br /> ' vRcna v°Ra aerAu I I - <br /> 17. TOWEL BAR BLK'G @ 48 A.F,F.t BLOCK BOTH SAYS. <br /> I8. TOILET PAPER HOLDER BLK'G @ 22"A.F.F.AND 42"FROM BACK IJ l P I L IJL.E TAIL @ J 19. THERMO5TAl BLK'G a 60'A.FF C /�A yp S `SOFFIT TO BTM OUTDOOR _ 3'-0° 256s <br /> 20. EXTERIOR LIGHT BLOCKS AT ALL FRONT ENTRY'S SHALL BE IN LLi L '- SLIDING GLASS DOOR! T OF BM,TIP 1710x510 � o g (5G) <br /> 21. THE TOP OF THE EXTERIOR LIGHT BLOCKS AT GARAGE 5HALL ALIGN..I 14 yr Or 7HJF IAII` c" N t=�T`JT• v <br /> GARAGE DOOR TRIM SCALE:N.T.S. 6040 XOX NOOK <br /> 2. ADD CONY.BLOCKING FOR STAIR HANDRAIL BRACKETS + 1 <br /> 23. STAIRS ww;'F.WINDER STEPS WILL ALWAYS NAVE A CONTINUOUS HANDR:.IL rr�.-,-!=Li rLJ L..L <br /> THE L OF THE STAIR RUN fOIx12lEQ CPT - <br /> 24. LADDER-BLOCK AT EXTERIOR WALLS AS NECE55ARY FOR INSUL.A N Ir, 1 <br /> GPT <br /> �� <br /> 1 0 28' _ 4'-0~_ 2'- ' INSTALL(2) <br /> VENTILA TUN FRONT DooR IP R PLAN 3CM OVERHANGS TO BE W 4 2x6 STACKED <br /> 25, WHOLE HOUSE VENTILATION SHALL BE PROVIDED BY A CEIJ fkA�taWrL.-)��":;a I'1 - 2CM OVERHANGS TO BE 8" <br /> Al<FDAR.TOE KIIX -, RANGE HOD <br /> ACCORDANCE WITH M1505 A.LI. ceNrEREDa Lean -�- <br /> 26. WHOLE HOUSE FAN 5°iALL OPERATE CONTINUOUSLY. " FRONT .STAB N - BOTH SIDES <br /> 27. WHOLE HOUG FOR <br /> SE FAN GM RATE BASED ON TABLE M1505.4.3(I).tXAnl LI. �„2b0U D25 = <br /> J _ <br /> OF CENTER <br /> STUD @ <br /> SF HOME w/4 BEDROOMS,AND THEN INCREASE BY FACTOR Of -k?= eLEVATION 12 z D/w Dw AIR <br /> M1505.4.3(2)TO ACCOUNT FOR NOT-BALANCED,NOT-DISTRIBUTED vErdfl,4T:SI:SrSTEM b GREAT ROOM _-GAP,Dw <br /> 2.B PLATE @ DOOR THRESNOLD _ ELECTRIC _ L _ m <br /> 28. WHOLE HOUSE FAN 5HALL BE LO 5OJES OR LESS,AND SHALL HAVE AIN EFH(:?.C,OF:73 RAISED WALL, (zyeP:TO BE m FIREPLACE - I5'4XI7' SIDE _ <br /> ,n _ I <br /> CFM/WATT PER W5EC R403.6.1. RIPPED TO V REMOVED PRIOR , <br /> 29. FRESH AIR 5HALL BE INTRODUCED INTO THE HOUSE VIA OPCRABLL IIIC f - t a N.H. To FRONT <br /> B' -FLOOR TOE KICK 5TEP/WALK BEING R ° CENTER co <br /> CODE INTERPRETATION 17-15. I_JasT @ DOOR POIReED o <br /> 0 <br /> W. PROVIDE AFRESH AIR TRANSFER GRILL ABOVE DOOR HEADER IN Hh k'u 1111 IIIF ER PLAN w -- <br /> m a = O!® STUD BAY <br /> WHOLE.HOUSE hAN. +PAPER = �+ � � ON RANGE � j- <br /> 31. PER IRO MIhOlA 5.:WHERE 1"NE DRYER VENT EXHAUST DUCT K C I t:;n e� fHIIv THE NN JOlsi _ o ! <br /> BUILDING CONSTRUCTION,THE EQUIVALENT LENGTH OF THE EXHfI, 1 DUCT LL BE CPT KITCHEN SEELAY CAB <br /> IDENTIFIED GN a PERMANENT LABEL OR TAG. THE LABEL OR T.,G oHALL.„E:Q,a"FED WALL BEYOND FRONr PaRaIS <br /> a T.O.RS RUN FAN 106XI2'3 FGR LocWITHIN;FT OFME EXHAUST DUCT CONNECTION. UT <br /> RaIsSD SLAB,SIp'EPORCH STEM WALL 70 DUCT TO 3'-IJ' 6'-Q' T=51" " q'_IV'2 7'_ SECTION5T� Y'PEFT.R LINMA, T.O.FRONT PORCH TOILET or -- <br /> LI E GAF Y wALL` STEM WALL T SINK WALL 2x6 WALL MINI-SPLIT 0 BF' <br /> - --<�-- <br /> DOWN THRU <br /> 26. A HEAT ALARM OR HEAT DETECTOR RA ED FOR AMBIENT OUFOCvR IF-IFERATURES AND FRONT PORCH EXT. DETAIL - " <br /> N Y FER <br /> ELECTRIC <br /> C CRAWL <br /> HUMIDITY TO BE CENTRALLY LOCATED IN THE GARAGE. ELECTRIC m, SPACE< r ® _, i W/5(3) OPENG J ZLu <br /> 27, THE HEAT ALARM OR HEAT DETECTOR WILL BE CONNECTED 1"0 AN ALAki lI UR>I9ur.E D� SCALE:I/2'=I'-0' o - VENT TO - SD/CO � )ALARM THAT IS INSTALLED IN THE DWELLING AND LOCATED IN A HALLWAY. ROOM OR m OUTSIDE _ <br /> OTHER LOCATION THAT WILL PROVIDE OCCUPANT NOTIFICATION FIREPLACE OPT. 2 , 4 Y'b HWT TO BE <br /> 10. SMOKE DEFECTORS TO BE IIOV, INTERCONNECTED,w/BATTERY BACKUP i Ct:NTRALL7 �9 ,w.H,3' INSTALLED IN LOCATED IIJ EACH HABII'AF]LE ROOM. ADDITIONAL SMOKE DETECTORS 5}IAL....BE SCALE: I/4'=I'-0" aO -�' x n'31 DR CPTN 2868 LR. THE 3rd CAR <br /> INSTALLED WHERE THERE IS A CEILING HEIGHT CHANGE GREATER THAN=-. IT-2GARAGEORII. SMOY.E DETECTORS 5HALL BE INSTALLED 7aJty fA�I;F"ROT lNFGARAGE j \ <br /> NOT LENS THAN 3 FT Jkl b 4'BOLLARD 27° BUMP-OUT WHEN <br /> DOOR OR <br /> OPENING OF A BATHROOM THAT CONTAINS TUB OR SHO Nq C SI-i ®TR _ THAT OPT.15 N <br /> 12. IONIZATION SMOKE ALARMS: �' Yv LINE OF <br /> x SHALL NOT BE INSTALLED LESS THAN 20 FT HORIZONTALLY FRO Fi I AJEN,L'! LI1 AF SELECTED. 1 <br /> IN5TALLED COOKING APPLIANCE. <br /> x IONIZATION SMOKE ALARMS WITH AN ALARM-SILENCING SWITCH 5HALL F;G(:SE IN°I ALLEi J �.I�-- CPT <br /> LESS THAN 10 FT HORIZONTALLY FROMA PERMANENTLY INSTALLED C.i1G<,h,APPLIANC:= i vN`yer CPTN <br /> 24. PHOTO ELECTRIC SMOKE ALARM5 SHALL NOT BE INSTALLED LESSNCFHAN E f o �i 24. GARAGE <br /> HORIZONTALLY FROM A PERMANENTLY INSTALLED COOKING APPLIAE L 51H �� _-1 TIT 19'IX19'7 <br /> 25.GARAGE NOTE:WRAP ALL WARM WALLS AND SUPPORTING MEMBEk WITH I/; G w.G,a 5�.' 18°x24'CRAWL coPrrswur NorKE.TUIs <br /> TYPE'X'OIJ THE CEILING.POLY SEAL RIM,ENTIRE GARAGE fO M cT URI C.CTIO! ^^�Ia- -. wr GARAGE NOTE:WRAP ALL WARM <br /> m SPACE ACCESS - _ RIDGE <br /> 15 OWNED BY F TWIC <br /> DRAFT STOP REQUIREMENTS �- WALLS AND SUPPORTING MEMBERS RILY.E HmEs.USE O THIS <br /> 26. ENCLOSED USABLE SPACE UNDER STAIRS TO BE PROTECT ED WITH'!-_"'.aWb TI IId - ^o IT FOYER WITH 1/2'G.W.B.t 5/B"TYPE'X'ON PLAN Is PRO48TED BT LAYN <br /> THE CEILING <br /> e@TENSE FEE TO PACIFIC <br /> HAT PameNr aWALLS,UNDER-STAIR SURFACES AND SOFFITS. M LIC n . <br /> 27. PROVIDE FIREBLGrKING PER PLAN AND ALL PLUMBING PENETRhliGNS. 3 ..`T RIDGE WOMBS <br /> . i <br /> _ 36'KNEE sr W5 <br /> WALL BELOW rt 3B'HL HALF AIO PLAN SUMMARY <br /> 3T FOR m wa a eeaR®rt so.rr.. <br /> x IT 3° V - UTILITY r: <br /> LAYOUT, <br /> -- 2 UP Sw r SEE W5/AID 814 <br /> (PIC) 15 3'"� 15 P14T <br /> N I--HI FT. <br /> 195 <br /> 5'_0 1, 3'_p I'-9VZ' '_5' _ 2030 I'-9V2' 3'-2" I'-q2' 15070 GARAGE DOOR <br /> - 'J PIC -- F 0 ry 2009 <br /> (SIG) LINE OF FLOOR ABOVE <br /> �I q FRONT PORCH b PORC I m 405 <br /> 66 5F - 27 5 0 JT- <br /> 1 Ii � m GAunerema� <br /> O3 Z„ 9 3B I JWA <br /> A4 I <br /> Q I Rnlms <br /> BTL ENGINEERING <br /> Q <br /> ' Im' A 5EE REVISION LOG <br /> 12' 12' 4'-9° 12' I'-II' 15'-3°R.O. 2'_''j' <br /> I <br /> SCALE: li' 1'-0° <br /> DRIVEWAY s� <br /> 10' WIDTH EXTENDED FRONT PORCH MAIN FLOOR PLAN <br /> _/PORCH PLAN OPTION - 'A' ELEV. MAIN FLOOR PLAN - 'A' ELEV SCALE: 3/8'-1'-0' SCALE: 1/4'•V-0' - <br /> SCALE 1/4'=1'-0' <br />