SLIDIPiG„L.SS D7R
<br /> SLIDI
<br /> G CLASS
<br /> UP JAMB
<br /> ��-NAIL
<br /> c rGE+ING R EXTEND MIN.b'NERVASTRAL TO EXTEND
<br /> SELF ADHESIVE
<br /> MEMBRANE PAN
<br /> FLASHING NAIL t vti
<br /> NAIL ON FLEXIBLE
<br /> FLASHING \ �-2 MI F RON r F OF THE DOOR PAST THE INTERIOR
<br /> ///� \�LEADER/ \ HEADER/
<br /> FLOOR JOIST \\ // LEDGER TO'_AG 5 RD STLu
<br /> PER PLAk-- j, j/ 5/4x4-�EDAR D EC,ING -- ROUGH I.GH -
<br /> n�_ - PER PLAN WAT -I;' OPENING OPENING
<br /> BARRI ILR -
<br /> _ - 2x P JOIST=-'FLAN - *JAMB\ JAMB\
<br /> -LARGER,PER FL-N JOINT FL ."II" 2ND PIECE / SILL \ !I / SILL \
<br /> �I --I IN
<br /> RIM JOIST - IN M DER,IE PENETRATION -I -- PT LEDGER`EE<r_A,N COLT- _ Isr p
<br /> BUILDING-PAPER �-SHEATHING PER PLAN /fCf 12' SILL -
<br /> ( n
<br /> INSTALLED BEHINDi - SIDI lu F ' FLASHING
<br /> OVRkING.L WRAP ` /LEDGER INER AND PAN STALLED ED BEFORE 51DIt+, BUILDING PAPER TO EXTEND - ...
<br /> FLASHING.LAP y PLAN' __ PL, III MIN.12'BEYOND ALL EDGES ---
<br /> STEP STEP 2 Q EXTEND 12"BEYIXJD a •ATTACH SILL STRIP OF 9'WIDE MOISTOP(OR EQ,)FLASHING MATERIAL •ATTACH JAMB STRIPS OF 9'WIDE MOISTOP(OR EQ,).
<br /> a,/BUILDING PAPER BENINID IT wi< ` EXTEND
<br /> OPENING `-' OF THE PENETRATION u-A
<br /> EXPOSED ON ALL 4 SIDES ` - WITH THE TOP EDGE EVEN WITH THE TOP OF THE ROUGH SILL. FLASHING MATERIAL WITH INSIDE EDGE EVEN WITH THE JAMB
<br /> •EXTEND THIS STRIP AT LEAST 12'BEYOND THE EDGE OF THE ROUGH OF THE ROUGH OPENING. Z
<br /> OPENING. •START JAMB STRIPS 2"BELOW SILL STRIP AND EXTEND 6"
<br /> DEC LEDGER DETAIL SD .I _�;1� FLASHING EXTERIOR DOOR FLASHING fI�J PENETRATION PROTECTION •ATTACH FLASHING MATERIAL W W
<br /> WITH CORR0510N-RE515TANT STAPLES. ABOVE LOWER EDGE OF HEADER.
<br /> SCALE. T 5 _ - W15 SCALE:NI U SCALE:N.T.S. nn—/ CID
<br /> rrNrER mn ur+ona4 a+ t ��f� - O
<br /> FRtMt Dmx i wEwslE Y S COAT.BEAD OF -
<br /> �SEALANT v
<br /> EQ. EQ. FLASHING - UNDER NAIL FIN
<br /> sGO PER PLAN
<br /> 2° ❑ 2' Q
<br /> - OPERPBLE FIXED
<br /> PANEL PANEL_J I CUT AWAY
<br /> ____ ___ _..-.-.- _I WINDOW -.-.-.-_EXCESS WINDOW I�
<br /> BEHIND Tww 1 Ea Au.RIDES,c4 I—TRIM,
<br /> LK/SFAL �- FRAMEIMI�RR BLW.PAPER FRAME OR Y • 1
<br /> C.L.OF LINE OF (. EI @OPENING SIMILAR L�1
<br /> Cj 5'-b"TO H05E BIB
<br /> 5'-6"TO Bmom OF - S'"S'LANDING TYP. *NOTE: SEAL ALL OPENING ..-.....-_�
<br /> E0. *��� � - EQ. OPENING I �J
<br /> POUR AGAII5T BUILDING PRONTO NERVASTRAL EXPOSED FASTENERS
<br /> FRONT PORCH PATIO BUILDING PAPER
<br /> BEND _ELECTRICAL V-6'LANDING TYP SHEATHING PER PLAN TYP.
<br /> PAPER T�
<br /> METER MAIN °°°'PATdi'11°AD'R'""'s LINE OF BUILDING PAPER
<br /> ® @BACK PATIO'S I: SipEa '� INSULATION BLW PAPER
<br /> _ NAIL FLANGE UNDER SILL STRIP
<br /> APPROVED
<br /> FRONT--� ' �NOF BCkvc- THRESHOLD _� -_-AG HEARTED CEDAR�� 536 NEARTwLnD C DAR PER PLAN S DI> FERRPLANI IxI/2'GAP SAPNAILINGYA 3/8'CONTINUOUS
<br /> O T INUOUSI BEAD
<br /> OF THE WINDOW THE BACK OF THE FRAME •APPLY THE NEXT COURSE OF BUILDING PAPER BUTTING TO THE
<br /> INSTALLED vl, DOOR ) STEP 3 ST ( �\
<br /> CORNER LANDING PER PLAN.POUR
<br /> OF HOUSE AGAINST NERVEStRAL ` FRAME OPENING)OVER THE JAMB FLASHING MATERIAL cop
<br /> AT HOSE Ott FELT F�rt�. TRIn wr FLAR{IING t BTWN ROOF AND SIDING •PLACE AND SECURE FRAME INTO ROUGH OPENING WITH FLANGES OVER THE •APPLY SUCCEEDING LAYERS OF BUILDING PAPER IN SHINGLE NER""A' _ LOUSE INTERSECTION,
<br /> BIBB STARTER 1 RIF' -LANDING.FEP Av I_ -. WHERE OCCURS INSTALLED JAMB AND SILL R JAMB MOISTOP(OR E0.)FLASHING MATERIAL. BOARD FASHION UP THE WALL,LAPPING COURSES A MINIMUM OF
<br /> (MIN B)TTF I ROOF SHINGLES •NAIL WINDOWS PER WINDOW MANUFACTURER'S SPECIFICATIONS 1/2 PAPER WIDTH. � T
<br /> INSTALL - j' ,___
<br /> GROUNDINta 4 OF TEPs-73'by LINE OF HERVERTRAL •STARTING FROM THE BASE OF THE WALL,APPLY BUILDING PAPER UNDER
<br /> FLASHING NUD SILL EtDNDr,!�Y+S 'Aa FELT TO EXTEND UP
<br /> -ROD 12"FROMI - - - _.._ THE SILL STRIP AND CUT ANY EXCESS BUILDING PAPER THAT MAY EXTEND
<br /> ---- WALL I2'MIN,
<br /> PRONTO BEND �� tONc.wat S�OR GRADE ABOVE THE SILL AND BETWEEN THE JAMB5 OF THE OPENING.
<br /> GUTTER PER
<br /> FORTIFLA.,P c/FLASHIN . •ADD FORTIFLASH STICK FLASHING @ BOTH SIDES OF WINDOW f
<br /> r PIG Cr PLAN___ --1� ROOF TRUSS a^F°ET
<br /> AND NONSTOP.TURN - - - - Am raxNr Paw¢TALL - •APPLY SLOPED 28 GA..2"BACK,PREFINSHED METAL FLASHING TO OPENNG,
<br /> FORTIFLA514 I"ONTO PANEL, y` ,1 ROOF SHEATHING PER PLAN •APPLY 6'FORTIFLA514 OVER TOP HEAD FLANGE OF WINDOW.EXTEND PAST
<br /> ALL SIDES E CORNERS FASCIA PEI PIA I EXT. LANDING DETAIL @ ROOF TRU55 JAMB FLASHING 2". p
<br /> p tl k
<br /> F` "` SLIDING GLASS DOOR TYP L 2C'TRII'1�"PER'METER-- FL�,SNII i.� I.__ -.-�� @ EAVE � ROOF 70 WALL FLASHING STANDARD FLASHING MATERIAL APPLICATION AT OPENINGS Q
<br /> OPENING FOR ELEC.-- ', I Wl3 CAL-NT5 W12 SCALE:N.T.S. WII SCALE:N.T.5. SCALE:N.T.S. --- l
<br /> METER BOX,FIREPLACE n BERN'.
<br /> DIRECT VENT, RANGE VENT, nETER?'WIN V u 1
<br /> DRYER'VENT,ETC. SENT WINDOW FRAME L-IL-L
<br /> SEE DETAIL WIO FOR 1106TOP INSTALL INSTRUCTIONS SILL ASSEMBLY 3/8"BEAD CAULK INSULATION
<br /> 7/16"PLYWD.SHEATHING „\
<br /> ELECTRIC METER HOSE BU PER SPEC— SEALANT (WHERE OCCURS) --6'FORTIFLASH 0/FLASHING
<br /> r 1v� TRIM PER ELEVATION GYP.BD. KID.FRAME WALL -SIDING PER PLAN
<br /> /'��LOCATION (NO GAS METER) L r' (WHERE APPLICABLE) INSULATION PER PLAN BUILDING PAPER
<br /> (IV.I, C SCALE:N.T.5. TRIMMER (WHERE DO,
<br /> R-10 INSULATION NONSTOP(SEE DETAIL WHO
<br /> \�5 MOISTOP SEE DETAIL
<br /> GYP.BD WIO FOR INSTALL) HD.STUD WD FRAME WALL BEHIND HER,TYP @ FOR INSTALL)
<br /> ALL HDR's MIN.1/4'GAP 51 SIDING
<br /> 'MIN.Is' EXT WALL PER FORTIFLASH ON ALL SEALANT PER PLAN GYP BD I'. ��-AND FLASHING COPYRIGHT NOTICE:THIS
<br /> PLAN SIDES OF WINDOW MOISTOP(SEE �l PLAN rAN I5 NED BY PACIFIC
<br /> DETAIL WIO HEADER PER PLAN _ FLASHING TURN DOWN RIDGE HOMES,USE OF THIS
<br /> FOR INSTALL) 7/16'PLYWD.SHEATHING 1/4'AT EACH END�� PLAN IS PROHIBITED Br LAw
<br /> ---- SIDING PER PLAN WITHOUT PAYMENT OF
<br /> Its INSULATION LICENSE FEE TO PACIFIC
<br /> Ln� WINDOW FRAME -TRIM PER ELEVATION
<br /> APER TYP. (WHERE OCCURS) BLW.PAPER BLDG.PAPER RIDGE HOMES.
<br /> SEALANT (SEE ELEV,FOR (WHERE APPLICABLE) /
<br /> _. 10'-6"TO HOSE BIB 'ER PLAN SIDING PER PLAN 'WINDOW NT)
<br /> 8'-6"TO C.L. - 7/Ib'PLYWD.SHEATHING TRIM PER ELEVATION SEALANTPC PLAN SUMMARY
<br /> 1 OF PRONTO BEND,,,_,_,___,_-, —.�11_.-� 9ED TRIM - (WHERE APPLICABLE) FORTIFLASH ON ALL SEALANT
<br /> u*a°tee.cc a•eRen ee.rr.
<br /> 11_
<br /> SIDES OF WINDOW WINDOW FRAME
<br /> !- GE �E )RNER �1 WINDOW SILL @ WOOD FRAME WALL W7 WINDOW JAMB DETAIL W6 WINDOW HEAD DETAIL EWE TO EWE TO I I WOI � - LIn
<br /> EWE EWE _ELECT Rb_�.L SCALt v g VVU SCALE:N.T.S. SCALE:N.T-S. SCALE:N.T.S. 814
<br /> / METER FAIN
<br /> ® RONTc b a-- q5
<br /> FRONT- n T'LED U,
<br /> OF CORNER
<br /> LAP SIDING,U.NO.(HOLD 1-1/2' POINT LOADS ABOVE VENTS - 2009
<br /> T ^F- LSE STUDS @ I6'oc NO POSTS/
<br /> / OFF ADJOINING ROOF /.x s / ) �+KF UIFA'g Fr..
<br /> Al GARAGE nOoE )
<br /> IBIS B " 'SCREW METAL FLASHING SIDING PER PLJR111
<br /> 405
<br /> _Y ATTACHED
<br /> j TER i .STUDS.LPG (MAY BE STEPPED) /�! ��/ EQ. -� BOTTOM SILL P "�'T 9A"0�
<br /> ;.; s_I: 0 PENETRATE BUILDING PAPER ON = i 3/4"TfG SUBFL_.._.-_.. -�.. - GAS
<br /> n D'"F .�: :T.L- MIN.,TYP.@ I,I wu rwsrmxwATa
<br /> SHEATHING(SIDING CUT
<br /> dD 2/3 NT OF AWAY FOR CLARITY) w i i FLASHING JWA
<br /> FORTIFLASH a/RASNWG TACH w/I ' I I 7-I/2"xl5-I/2°C
<br /> AND M015TOP.TURN ", MC,STOr 1.STRAP MIN METAL RAIN DIVERTER(THE I I VENTS w/GAL eBTLIBTL ENGINEERING
<br /> � PURP05E I5 TO SHED THE PROVIDE LOUVE
<br /> FORTIFLASH I"ONTO PANEL, WATER OFF THE ROOF AND @ FRONT ELEVAALL SIDES t CORNERS. HT OF HWT KEEP IT AWAY FROM THE i ROOF SHINGLES SEE REVISION LOG
<br /> H, PER SPEC. RIM PER PLANj
<br /> 2a2 TRIM @PERIMETER T VERTICAL WALL BENEATH), P.T.MUD SILL SCALE: Y'=I'-0"
<br /> OPENING FOR ELEC. lT OF HW1T FASCIA PER PLAN w/
<br /> ,/' 30tt ROOF FELT CONCRETE FOUNDATION ,sffr�reDs
<br /> MITER BOX,FIREPLACE P GUTTER 7/I6'058 ROOF **DO POT INSTALL VENT(5)CLOSER THAN 3'TO GAS METER** WATER
<br /> ENT DIRECT VENT,RANGE V , METER �.
<br /> DRYER VENT, ETC SHEATHING :*BUILDING PAPER SHOULD BE INSTALLED OVER FLASHING** INTRUSION
<br /> >SEE DETAIL MO FOR MOISTOP INSTALL IN5TRUC7I0:S - NOTE:PER WSEC R4022.7:WHEN FOINDATON VENTS ARE NOT PLACED SO THAT THE TOP DETAILS
<br /> /� *NOTE: SEAL ALL OF THE VENT IS BELOW THE LOWER SURFACE OF THE FLOOR INSULATION,A PERMANENTLY
<br /> ELECTRIC GAS METER HV..:1` ATTACHED BAFFLE SHALL BE INSTALLED AT AN ANGLE OF 30'FROM HORIZONTAL,TO
<br /> USE 3 STRAPS ON 75 GALLON AND GREATER SIZES EXPOSED FASTENERS DIVERT AIR FLOW BELOW THE LOWER SURFACE OF THE FLOOR INSULATION
<br /> g BIB CLEARANCES It LOCATIONS WATER HEATER (HWT) STRAPS DETAIL @ ROOF/WALL INTERSECTION
<br /> YYL FOUNDATION VENT f�
<br /> I.Ir_
<br /> VVJ SCALE:N.TS. --- SCALE:N.T.S. SCALE:N.T.S. YVI SCALE:N.T.S.