Laserfiche WebLink
SLIDIPiG„L.SS D7R <br /> SLIDI <br /> G CLASS <br /> UP JAMB <br /> ��-NAIL <br /> c rGE+ING R EXTEND MIN.b'NERVASTRAL TO EXTEND <br /> SELF ADHESIVE <br /> MEMBRANE PAN <br /> FLASHING NAIL t vti <br /> NAIL ON FLEXIBLE <br /> FLASHING \ �-2 MI F RON r F OF THE DOOR PAST THE INTERIOR <br /> ///� \�LEADER/ \ HEADER/ <br /> FLOOR JOIST \\ // LEDGER TO'_AG 5 RD STLu <br /> PER PLAk-- j, j/ 5/4x4-�EDAR D EC,ING -- ROUGH I.GH - <br /> n�_ - PER PLAN WAT -I;' OPENING OPENING <br /> BARRI ILR - <br /> _ - 2x P JOIST=-'FLAN - *JAMB\ JAMB\ <br /> -LARGER,PER FL-N JOINT FL ."II" 2ND PIECE / SILL \ !I / SILL \ <br /> �I --I IN <br /> RIM JOIST - IN M DER,IE PENETRATION -I -- PT LEDGER`EE<r_A,N COLT- _ Isr p <br /> BUILDING-PAPER �-SHEATHING PER PLAN /fCf 12' SILL - <br /> ( n <br /> INSTALLED BEHINDi - SIDI lu F ' FLASHING <br /> OVRkING.L WRAP ` /LEDGER INER AND PAN STALLED ED BEFORE 51DIt+, BUILDING PAPER TO EXTEND - ... <br /> FLASHING.LAP y PLAN' __ PL, III MIN.12'BEYOND ALL EDGES --- <br /> STEP STEP 2 Q EXTEND 12"BEYIXJD a •ATTACH SILL STRIP OF 9'WIDE MOISTOP(OR EQ,)FLASHING MATERIAL •ATTACH JAMB STRIPS OF 9'WIDE MOISTOP(OR EQ,). <br /> a,/BUILDING PAPER BENINID IT wi< ` EXTEND <br /> OPENING `-' OF THE PENETRATION u-A <br /> EXPOSED ON ALL 4 SIDES ` - WITH THE TOP EDGE EVEN WITH THE TOP OF THE ROUGH SILL. FLASHING MATERIAL WITH INSIDE EDGE EVEN WITH THE JAMB <br /> •EXTEND THIS STRIP AT LEAST 12'BEYOND THE EDGE OF THE ROUGH OF THE ROUGH OPENING. Z <br /> OPENING. •START JAMB STRIPS 2"BELOW SILL STRIP AND EXTEND 6" <br /> DEC LEDGER DETAIL SD .I _�;1� FLASHING EXTERIOR DOOR FLASHING fI�J PENETRATION PROTECTION •ATTACH FLASHING MATERIAL W W <br /> WITH CORR0510N-RE515TANT STAPLES. ABOVE LOWER EDGE OF HEADER. <br /> SCALE. T 5 _ - W15 SCALE:NI U SCALE:N.T.S. nn—/ CID <br /> rrNrER mn ur+ona4 a+ t ��f� - O <br /> FRtMt Dmx i wEwslE Y S COAT.BEAD OF - <br /> �SEALANT v <br /> EQ. EQ. FLASHING - UNDER NAIL FIN <br /> sGO PER PLAN <br /> 2° ❑ 2' Q <br /> - OPERPBLE FIXED <br /> PANEL PANEL_J I CUT AWAY <br /> ____ ___ _..-.-.- _I WINDOW -.-.-.-_EXCESS WINDOW I� <br /> BEHIND Tww 1 Ea Au.RIDES,c4 I—TRIM, <br /> LK/SFAL �- FRAMEIMI�RR BLW.PAPER FRAME OR Y • 1 <br /> C.L.OF LINE OF (. EI @OPENING SIMILAR L�1 <br /> Cj 5'-b"TO H05E BIB <br /> 5'-6"TO Bmom OF - S'"S'LANDING TYP. *NOTE: SEAL ALL OPENING ..-.....-_� <br /> E0. *��� � - EQ. OPENING I �J <br /> POUR AGAII5T BUILDING PRONTO NERVASTRAL EXPOSED FASTENERS <br /> FRONT PORCH PATIO BUILDING PAPER <br /> BEND _ELECTRICAL V-6'LANDING TYP SHEATHING PER PLAN TYP. <br /> PAPER T� <br /> METER MAIN °°°'PATdi'11°AD'R'""'s LINE OF BUILDING PAPER <br /> ® @BACK PATIO'S I: SipEa '� INSULATION BLW PAPER <br /> _ NAIL FLANGE UNDER SILL STRIP <br /> APPROVED <br /> FRONT--� ' �NOF BCkvc- THRESHOLD _� -_-AG HEARTED CEDAR�� 536 NEARTwLnD C DAR PER PLAN S DI> FERRPLANI IxI/2'GAP SAPNAILINGYA 3/8'CONTINUOUS <br /> O T INUOUSI BEAD <br /> OF THE WINDOW THE BACK OF THE FRAME •APPLY THE NEXT COURSE OF BUILDING PAPER BUTTING TO THE <br /> INSTALLED vl, DOOR ) STEP 3 ST ( �\ <br /> CORNER LANDING PER PLAN.POUR <br /> OF HOUSE AGAINST NERVEStRAL ` FRAME OPENING)OVER THE JAMB FLASHING MATERIAL cop <br /> AT HOSE Ott FELT F�rt�. TRIn wr FLAR{IING t BTWN ROOF AND SIDING •PLACE AND SECURE FRAME INTO ROUGH OPENING WITH FLANGES OVER THE •APPLY SUCCEEDING LAYERS OF BUILDING PAPER IN SHINGLE NER""A' _ LOUSE INTERSECTION, <br /> BIBB STARTER 1 RIF' -LANDING.FEP Av I_ -. WHERE OCCURS INSTALLED JAMB AND SILL R JAMB MOISTOP(OR E0.)FLASHING MATERIAL. BOARD FASHION UP THE WALL,LAPPING COURSES A MINIMUM OF <br /> (MIN B)TTF I ROOF SHINGLES •NAIL WINDOWS PER WINDOW MANUFACTURER'S SPECIFICATIONS 1/2 PAPER WIDTH. � T <br /> INSTALL - j' ,___ <br /> GROUNDINta 4 OF TEPs-73'by LINE OF HERVERTRAL •STARTING FROM THE BASE OF THE WALL,APPLY BUILDING PAPER UNDER <br /> FLASHING NUD SILL EtDNDr,!�Y+S 'Aa FELT TO EXTEND UP <br /> -ROD 12"FROMI - - - _.._ THE SILL STRIP AND CUT ANY EXCESS BUILDING PAPER THAT MAY EXTEND <br /> ---- WALL I2'MIN, <br /> PRONTO BEND �� tONc.wat S�OR GRADE ABOVE THE SILL AND BETWEEN THE JAMB5 OF THE OPENING. <br /> GUTTER PER <br /> FORTIFLA.,P c/FLASHIN . •ADD FORTIFLASH STICK FLASHING @ BOTH SIDES OF WINDOW f <br /> r PIG Cr PLAN___ --1� ROOF TRUSS a^F°ET <br /> AND NONSTOP.TURN - - - - Am raxNr Paw¢TALL - •APPLY SLOPED 28 GA..2"BACK,PREFINSHED METAL FLASHING TO OPENNG, <br /> FORTIFLA514 I"ONTO PANEL, y` ,1 ROOF SHEATHING PER PLAN •APPLY 6'FORTIFLA514 OVER TOP HEAD FLANGE OF WINDOW.EXTEND PAST <br /> ALL SIDES E CORNERS FASCIA PEI PIA I EXT. LANDING DETAIL @ ROOF TRU55 JAMB FLASHING 2". p <br /> p tl k <br /> F` "` SLIDING GLASS DOOR TYP L 2C'TRII'1�"PER'METER-- FL�,SNII i.� I.__ -.-�� @ EAVE � ROOF 70 WALL FLASHING STANDARD FLASHING MATERIAL APPLICATION AT OPENINGS Q <br /> OPENING FOR ELEC.-- ', I Wl3 CAL-NT5 W12 SCALE:N.T.S. WII SCALE:N.T.5. SCALE:N.T.S. --- l <br /> METER BOX,FIREPLACE n BERN'. <br /> DIRECT VENT, RANGE VENT, nETER?'WIN V u 1 <br /> DRYER'VENT,ETC. SENT WINDOW FRAME L-IL-L <br /> SEE DETAIL WIO FOR 1106TOP INSTALL INSTRUCTIONS SILL ASSEMBLY 3/8"BEAD CAULK INSULATION <br /> 7/16"PLYWD.SHEATHING „\ <br /> ELECTRIC METER HOSE BU PER SPEC— SEALANT (WHERE OCCURS) --6'FORTIFLASH 0/FLASHING <br /> r 1v� TRIM PER ELEVATION GYP.BD. KID.FRAME WALL -SIDING PER PLAN <br /> /'��LOCATION (NO GAS METER) L r' (WHERE APPLICABLE) INSULATION PER PLAN BUILDING PAPER <br /> (IV.I, C SCALE:N.T.5. TRIMMER (WHERE DO, <br /> R-10 INSULATION NONSTOP(SEE DETAIL WHO <br /> \�5 MOISTOP SEE DETAIL <br /> GYP.BD WIO FOR INSTALL) HD.STUD WD FRAME WALL BEHIND HER,TYP @ FOR INSTALL) <br /> ALL HDR's MIN.1/4'GAP 51 SIDING <br /> 'MIN.Is' EXT WALL PER FORTIFLASH ON ALL SEALANT PER PLAN GYP BD I'. ��-AND FLASHING COPYRIGHT NOTICE:THIS <br /> PLAN SIDES OF WINDOW MOISTOP(SEE �l PLAN rAN I5 NED BY PACIFIC <br /> DETAIL WIO HEADER PER PLAN _ FLASHING TURN DOWN RIDGE HOMES,USE OF THIS <br /> FOR INSTALL) 7/16'PLYWD.SHEATHING 1/4'AT EACH END�� PLAN IS PROHIBITED Br LAw <br /> ---- SIDING PER PLAN WITHOUT PAYMENT OF <br /> Its INSULATION LICENSE FEE TO PACIFIC <br /> Ln� WINDOW FRAME -TRIM PER ELEVATION <br /> APER TYP. (WHERE OCCURS) BLW.PAPER BLDG.PAPER RIDGE HOMES. <br /> SEALANT (SEE ELEV,FOR (WHERE APPLICABLE) / <br /> _. 10'-6"TO HOSE BIB 'ER PLAN SIDING PER PLAN 'WINDOW NT) <br /> 8'-6"TO C.L. - 7/Ib'PLYWD.SHEATHING TRIM PER ELEVATION SEALANTPC PLAN SUMMARY <br /> 1 OF PRONTO BEND,,,_,_,___,_-, —.�11_.-� 9ED TRIM - (WHERE APPLICABLE) FORTIFLASH ON ALL SEALANT <br /> u*a°tee.cc a•eRen ee.rr. <br /> 11_ <br /> SIDES OF WINDOW WINDOW FRAME <br /> !- GE �E )RNER �1 WINDOW SILL @ WOOD FRAME WALL W7 WINDOW JAMB DETAIL W6 WINDOW HEAD DETAIL EWE TO EWE TO I I WOI � - LIn <br /> EWE EWE _ELECT Rb_�.L SCALt v g VVU SCALE:N.T.S. SCALE:N.T-S. SCALE:N.T.S. 814 <br /> / METER FAIN <br /> ® RONTc b a-- q5 <br /> FRONT- n T'LED U, <br /> OF CORNER <br /> LAP SIDING,U.NO.(HOLD 1-1/2' POINT LOADS ABOVE VENTS - 2009 <br /> T ^F- LSE STUDS @ I6'oc NO POSTS/ <br /> / OFF ADJOINING ROOF /.x s / ) �+KF UIFA'g Fr.. <br /> Al GARAGE nOoE ) <br /> IBIS B " 'SCREW METAL FLASHING SIDING PER PLJR111 <br /> 405 <br /> _Y ATTACHED <br /> j TER i .STUDS.LPG (MAY BE STEPPED) /�! ��/ EQ. -� BOTTOM SILL P "�'T 9A"0� <br /> ;.; s_I: 0 PENETRATE BUILDING PAPER ON = i 3/4"TfG SUBFL_.._.-_.. -�.. - GAS <br /> n D'"F .�: :T.L- MIN.,TYP.@ I,I wu rwsrmxwATa <br /> SHEATHING(SIDING CUT <br /> dD 2/3 NT OF AWAY FOR CLARITY) w i i FLASHING JWA <br /> FORTIFLASH a/RASNWG TACH w/I ' I I 7-I/2"xl5-I/2°C <br /> AND M015TOP.TURN ", MC,STOr 1.STRAP MIN METAL RAIN DIVERTER(THE I I VENTS w/GAL eBTLIBTL ENGINEERING <br /> � PURP05E I5 TO SHED THE PROVIDE LOUVE <br /> FORTIFLASH I"ONTO PANEL, WATER OFF THE ROOF AND @ FRONT ELEVAALL SIDES t CORNERS. HT OF HWT KEEP IT AWAY FROM THE i ROOF SHINGLES SEE REVISION LOG <br /> H, PER SPEC. RIM PER PLANj <br /> 2a2 TRIM @PERIMETER T VERTICAL WALL BENEATH), P.T.MUD SILL SCALE: Y'=I'-0" <br /> OPENING FOR ELEC. lT OF HW1T FASCIA PER PLAN w/ <br /> ,/' 30tt ROOF FELT CONCRETE FOUNDATION ,sffr�reDs <br /> MITER BOX,FIREPLACE P GUTTER 7/I6'058 ROOF **DO POT INSTALL VENT(5)CLOSER THAN 3'TO GAS METER** WATER <br /> ENT DIRECT VENT,RANGE V , METER �. <br /> DRYER VENT, ETC SHEATHING :*BUILDING PAPER SHOULD BE INSTALLED OVER FLASHING** INTRUSION <br /> >SEE DETAIL MO FOR MOISTOP INSTALL IN5TRUC7I0:S - NOTE:PER WSEC R4022.7:WHEN FOINDATON VENTS ARE NOT PLACED SO THAT THE TOP DETAILS <br /> /� *NOTE: SEAL ALL OF THE VENT IS BELOW THE LOWER SURFACE OF THE FLOOR INSULATION,A PERMANENTLY <br /> ELECTRIC GAS METER HV..:1` ATTACHED BAFFLE SHALL BE INSTALLED AT AN ANGLE OF 30'FROM HORIZONTAL,TO <br /> USE 3 STRAPS ON 75 GALLON AND GREATER SIZES EXPOSED FASTENERS DIVERT AIR FLOW BELOW THE LOWER SURFACE OF THE FLOOR INSULATION <br /> g BIB CLEARANCES It LOCATIONS WATER HEATER (HWT) STRAPS DETAIL @ ROOF/WALL INTERSECTION <br /> YYL FOUNDATION VENT f� <br /> I.Ir_ <br /> VVJ SCALE:N.TS. --- SCALE:N.T.S. SCALE:N.T.S. YVI SCALE:N.T.S. <br />