<br /> FLOOR PLAN NOTES A OF SOAP 7
<br /> 'C CON RO NICHE,SHOWERJPAN F"I "I _
<br /> ER
<br /> PEX TUBING, I
<br /> I. CONTRACTOR SHALL VERIFY ALL NOTES,MATERIALS t CONDITIONS PRIOR TO TYR
<br /> CONSTRUCTION. SHOWER CONTROLS -
<br /> _
<br /> 16'024'xb'DEEP- -
<br /> WINDOWS I DOORS: SOAP NICHE
<br /> 2. ALL EXTERIOR WINDOW t DOOR HEADERS TO BE INSUL..ATED w/R-10 INSULATION. BUTT NICHE TILE
<br /> 3. WINDOWS t DOORS ARE SHOWN i NOTED AS NOMINAL 5iZE5. INTO FIELD TILE,
<br /> 4. WINDOW HEAD HEIGHT R.O.SHOWN PER ELEVATIONS. EGRES WINDOW SILL HEIGHT RO c TOP t SIDES ,
<br /> j %
<br /> MAX.42'A.F.F. 44x
<br /> S. ALL WOOD IN CONTACT WITH CONIC.TO BE PRESSURE'i REATED. SECTION A-A BUTT FIELD -
<br /> 6. EXTERIOR WALLS TO BE 2x6 STUDS @ 16"O.C., U.NO, (ZOOMED IN @ NICHE) TILE INTO
<br /> 7. GARAGE DOOR HEADERS @ 84'A.F.F. BOTTOM OF
<br /> 8. EXTERIOR SWING DOOR HEADERS @ 53 1/2'A.EF. (3)LAYERS V NICHE TILE 15142' 144V
<br /> 9. INTERIOR SWING DOOR HEADERS @ 83'A.F.F. POLY-I50 RIGID APPROX.STUD
<br /> 10, SWING DOORS TO FOLLOW CENTERLINE DIMEN510N IN PLANS QR 8E 3°MIN.ON HINGE SIDE, INSULATION,EXT. LAYOUT V-V2 6'-0' 4'-7' W-2" 2'-0' 4'-2Y
<br /> 11. GARAGE-TO-HOUSE DOOR TO BE A SOLID WOOD 1%'THICK 20-MINUTE FIRE-RATED DOOR WALLS ONLY _
<br /> w/A SELF CLOSING HARDWARE DEVICE, SHOWER DOOR�. ('1
<br /> 12. PER R311.3.I:THE LANDING OR FLOOR ON THE EXTERIOR SIDE OF ALL EXTERIOR DOORS 11 , '-1
<br /> EXCEPT THE FRONT DOOR SHALL BE NOT MORE THAN 7-3/4"BELOW THE TOP OF THE
<br /> THRESHOLD PROVIDED THE DOOR DOES NOT SWING OVER THE LANDING OR FLOOR � FIELD TILE u-1
<br /> 13, ALL BI-FOLD t BI-PASS DOORS TO BE CENTERED,U.NO. 2030 �1- z
<br /> �u XO FRAMING: 6046 XO(EGRESS) � V
<br /> )
<br /> 5
<br /> 14. VERIFY FIREPLACE STYLE t LOCATION w/SUPERVISORSHOWER PAN PRIOR TO CONST. I--�-
<br /> 1. FRAMERS TO INSTALL ALL WINDOWS It INTERIOR COLUMNS SECTION A-A 2x6 ar 2x4 2x8 WALL, SECTION A-A CPT
<br /> 16, TOWEL RING BLK'G @ 57'A.F.F. (@ EXTERIOR HALL) WALL PER PLAN BACK WALL OF (@ INTERIOR WALL) �,
<br /> 17. TOWEL BAR BLK'G @ 45'A.F.F.t BLOCK BOTH BAYS. SHOWER,TYP. , 1 1
<br /> 18. TOILET PAPER HOLDER BLK'G @ 22'A.F.F.AND 42"FROM BACK WALL WHERE POSSIBLE [� SHOWER SOAP NICHE
<br /> 2' ' 2'-b' I'-*,'
<br /> 19. THERMOSTAT BLK'G @ 60' B[[J SCALE:NITS � BATP I '9
<br /> 20. EXTERIOR LIGHT BLOCKS ATT AL ALL FRONT ENTRY'S SHALL BE INSTALLED AT T-b"A.F.F.
<br /> 21. THE TOP OF THE EXTERIOR LIGHT BLOCKS AT GARAGE SHALL ALIGN WITH TOP OF THE I ;e 6'bxl3'8 T
<br /> GARAGE DOOR TRIM
<br /> 22, ADD CONT.BLOCKING FOR STAIR HANDRAIL&RACKETSLL-
<br /> BEDROOM I I °
<br /> 23. STAIRS w/WINDER STEPS WILL ALWAYS HAVE A CONTINUOJS HANDRAIL INSTALLED ON 1 , i 30'x80° tp w
<br /> THE INSIDE OF THE STAIR'S RUN DOUBLE RIM OR _ 123X152 I GWB FINISHED I^ , _
<br /> 24, LADDER-BLOCK AT EXTERIOR WALLS AS NECE55i:RY FCR INSULATION INSTALL PROVIDE SPLICE N I OPENING I a TBHic
<br /> °WER
<br /> VENTILATION: ; 6'IOx9'10
<br /> 25. WHOLE HOUSE VENTILATION SHALL BE PROVIDED BY I CENIRAL EXHAUST FAN IN
<br /> ACCORDANCE WITH MISMA.1.1.
<br /> 26. WHOLE H0U5E FAN SHALL OPERATE CONTINUOUSLY. °5C O 1 A x30°
<br /> SD i ATTIC I x
<br /> 27, WHOLE HOUSE FAN CFM RATE BASED ON TABLE M15GS,4.3(I).EXAMPLE:70 CFM FOR 2600 L ACCESS J 12'
<br /> 5F HOME w/4 BEDRCOMS,AND THEN INCREASE BY FACTOR OF 1.5 PER TABLE ADD FLAT ------ ---
<br /> M1505.4.3 2 TO ACCOUNT FOR NOT-BALANCED,NOT-DISTRIBUTED VENTILATION 5f5TE1. MINI-SPLIT W✓5(1) TP O
<br /> O 2X4 THROUGH
<br /> 28. WHOLE HOUSE FAN SHALL BE 1.0 SORES OR LESS,AND SHALL HAVE AN EFFICACY OF 2.3 JOIST @ 5'O.C. ° � MINI-SPLIT 24WALL
<br /> CFM/WATT PER WSEC R403.6.1. ��" W/S 3 UTILITY
<br /> 29. FRESH AIR SHALL BE INTRODUCED INTO TILE HOJSE VIA OPERABLE WINDOWS PER STAFF x - 5'4XI0'wNF
<br /> CODE INTERPRETATION 17-I5.
<br /> 30. PROVIDE A FRESH AIR TRANSFER GRILL ABOVE COOR!;EADER:N THE ROOM WITH THE _ H5 2p BF
<br /> WHOLE HOUSE FAN. 2'-10' CP
<br /> 31 p_2j+ -
<br /> et -�'3'-B' °
<br /> _ . PER IRO MI502.Ab.:WHERE THE DRYER VENT EX.�AUSl"DU 3'-9
<br /> CT IS CONCEALED WITHIN THE 2868 1
<br /> BUILDING CONSTRUCTION,THE EQUIVALENT LENGTH OF THE EXHAUST DUCT SHALL BE
<br /> 5TT HR5416Z.
<br /> IDENTIFIED ON A PERMANENT LABEL OR TAG. THE LIBEL OR TAG SHALL BE LOCATED ATTACH TO SECTION THRU
<br /> WITHIN 6FT OF THE EXHAUST DUCT CONNECTION WALL CAP T
<br /> 2%AND To LOFT _[
<br /> LIFE SAFETY: STAIR RIM a 3'9x18'7 32"xbo^ o Z
<br /> 4B°VANITY TP
<br /> 26, A HEAT ALARM OR NEAT DETECTOR RATED FOR AMBIENT OUTDOOR TEMPERATURES AND
<br /> HUMIDITY TO BE CENTRALLY LOCATED IN THE GARAGE CPT HALL BATH
<br /> 27. THE HEAT ALARM OR HEAT DETECTOR WILL BE CONNECTED TO AN ALARM OR SMOKE 51XIO'3 TB
<br /> ALARM THAT IS INSTALLED IN THE DWELLING AND LOCATED IN A HALLWAY,ROOM OR o M e
<br /> OTHER LOCATION THAT WILL PROVIDE OCCUPANT NOTIFICATION k ---- L-1-�
<br /> 10. SMOKE DETECTORS TO BE NOV, INTERCONNECTED,w/BATTERY BACKUP t CENTRALLY HALF WALL FRAMING 4 CAP DETAIL ,'�� � --_ _H/5(1) �
<br /> LOCATED IN EACH HABITABLE ROOM. ADDITIONAL SMOKE DETECTORS SHALL BE DI5 SCALE;I/2'=I-D" SD/CO _ ' _
<br /> INSTALLED WHERE THERE 15 A CEILING HEIGHT CHANGE GREATER THAN 24 p_2j+
<br /> 11. SMOKE DETECTORS SHALL BE INSTALLED NOT LESS THAN 3 FT HORIZONTALLY FROM iH, 15RN4T EQ 40 B EO
<br /> DOOR OR OPENING OF A BATHROOM THAT CONTAINS TUB OR SHOWER.ER3141 DN _
<br /> 12. IONIZATION SMOKE ALARMS: rt 42'H HALF WALL �4'10
<br /> SD5HALL NOT BE INSTALLED LE55 THAN 20 FT HOR!ZONTALLY FROM A PERMANENTLY _ O
<br /> INSTALLED COOKING APPLIANCE. MIN.30" ATTIC ACCESST"+ IONIZATION SMOKE ALARMS WITH AN ALARM-SILENCING SWITCH 5HALL NOT BE INS fA�LSD LESS THAN 10 FT HORIZONTALLY FROM A PERMANENTLY INSTALLED COOKING APPLIANCE_ CLEARANCE. SHEATHING qJ
<br /> 24, PHOTO ELECTRIC SMOKE ALARMS 5HALL NOT BE INSTALLED LE55 THAN 6 FT RUSSES MU T BE OUTSIIDE OFrt EQ gp EQ SD
<br /> HORIZONTALLY FROM A PERMANENTLY INSTALLED COOKING APPLIANCE IR314] INSTALLED @ 24'O.C. TRUSS MEMBERS ,`�� sT ,,, �1s OWN D eY PACIFIC
<br /> 25.GARAGE NOTE:WRAP ALL WARM WALLS AND SUPPORTING MEMBERS WITH 1/2'G.W.B.t 5,�c' - �T iRIDGE 5 PR5 USE OF THIS
<br /> TYPE'X'ON THE CEILING.POLY SEAL RIM, -ENTIRE GARAGE TO MEET JURISDICTIOF! ni Q b-T 3'-2° 3'-6' _b'-9'___ NTHMAN 15 PROHIBITED BY
<br /> wiTNOUT PAYMENT COf
<br /> I
<br /> DRAFT STOP REQUIREMENTS sr �� -_ LICENSE FEE TO PACIFIC
<br /> 26, ENCLOSED USABLE SPACE UNDER STAIRS TO SE PROTECTED WITH)'GWB AT I"HE RIDGE NdRS.
<br /> WALLS,UNDER-STAIR SURFACES AND SOFFITS.
<br /> 27. PROVIDE FIREBLOCKING PER PLAN AND @ALL PLUMBING PENETRATIONS, _ 58'H HALF m -' m PLAN SUMMARY
<br /> 5/4 TRIM GWB ATTIC 'rt WALL 43
<br /> � uva ca s.ueua v.n.
<br /> OR 51M. ACCE55 LID _
<br /> Er ATTIC ACCESS DETAIL IaT BEDROOM 2 BEDROOM 3 �^
<br /> v3 1 SCALES I/Y=1'-0' 9'4121 9'416'10 814 SFr,
<br /> I Iq5
<br /> mu Mc,aQ A,
<br /> GROUT t 4020 PIC 2009
<br /> SEALA-\
<br /> m^
<br /> SHOWER GLASS t
<br /> =. 5046 XO(EGRESS) 5046%0(EGRESS) 405
<br /> SLOPEFRAME w/GRID PER ELEV. w/GRID PER ELEV. ws mw.c
<br /> LINE OF WALL BELOW GAS
<br /> j! }"DRYWALL "n""""u'nun aaRow,vx,
<br /> JWA
<br /> LCERAMI12%S.A.M.,
<br /> SURRBITUTHENE BTL ENGINEERING
<br /> OR EQUIV. 2'-7�" 5'-0' 2' V' 2'-7Y' 5'-0" 2'-7Y4'
<br /> 2x4 STACKED SEE REVISION LOG
<br /> BLOCKING AT V-�' q'0' 2'-94' 9'-9° 10'-3'
<br /> SHOWER PANSHOWER CURB.(SOAKER TUBAT HALF SCALE: Y'-I'-0'
<br /> SIM.) WALL,FRAME 10'-0' 20'-0° aaer mu,na
<br /> LIKE HALF
<br /> SUB FLOOR WALL. 17 301_1+ UPPER FLOOR PLAN
<br /> TILED SHOWER CURB (HALF WALL SIM.) UPPER FLOOR PLAN - 1A1 � 1BI ELEV. SRI_-
<br /> VLV SCALE:3'=1'-0