Laserfiche WebLink
Ib' <br /> A <br /> FLOOR PLAN NOTES PIX TUBING, A q OC�NTORO NI°SHOWERWP N PPLAN <br /> TYR <br /> I. CONTRACTOR SHALL VERIFY ALL NOTES,M..-fERIALS t CONDITIONS PRIOR TO SHOWER CONTROLS <br /> CONSTRUCTION. - <br /> 10x24'X6'DEEP --- '� <br /> WINDOWS 4 DOORS: SOAP NICHE <br /> 1ALL EXTERIOR WINDOW t DOOR HEADERS TO BE INSULATED w/R-lu INSULATION. BUTT NICHE TILE _ <br /> 3. WINDOWS t DOORS ARE SHOWN t NOTED AS NOMINAL SIZES, INTO FIELD TILE, - <br /> 4. WINDOW HEAD HEIGHT R.O.SHOWN PER ELEVATIONS. EGRESS WINDOW SILL HEIGHT R,O A TOP t SIDES Z. <br /> - <br /> MAX.42"A.F.F. <br /> 5. ALL WOOD IN CONTACT WITH CONC.TO BE PRESSURE TREATED. SECTION A-A BUTT FIELD 24" b' m <br /> 6. EXTERIOR WALLS TO BE 24 STUDS @ 16'O.C.,U.NO. (ZOOMED IN @ NICHE) TILE INTO 301" <br /> 7. GARAGE DOOR HEADERS @ 84'A.F.F. BOTTOM OF <br /> 8. EXTERIOR SWING DOOR HEADERS @ 33 1/2'A.F.F. NICHE TILE 15'-7Y' 14'-442' <br /> (3)LAYERS I' <br /> 9. INTERIOR SWING DOOR HEADERS @ 83'A.F.F. POLY-I50 RIGID APPROX.STUD <br /> 10. SWING DOORS TO FOLLOW CENTERLINE DIMENSION IN PLANS 012 BE 3'MIN.ON HINGE SIDE, INSULATION,EXT. LAYOUT -0' 4-7" V-2° 2'-0' 4-2Xx" <br /> II. GARAGE-TO-HOUSE DOOR TO BE A SOLID WOOD IV THICK 20-MINUTE FIRE-RATED DOOR WALLS ONLY <br /> w/A SELF CLOSING HARDWARE DEVICE, SHOWER DOOR---` N <br /> 12. PER R311.3.1:THE LANDING OR FLOOR ON THE EXTERIOR 510E OF ALL EXTERIOR DOOR5 <br /> EXCEPT THE FRONT DOOR SHALL BE NOT MORE THAN 7-3/4'BELOW THE TOP Or THE <br /> THRESHOLD PROVIDED THE DOOR DOES NOT SWING OVER THE LANDING OR FLOOR FIELD TILE- ��-- <br /> 2030 <br /> 13. ALL BI-FOLD t BI-PA55 DOORS TO BE CENTERED,U.N,O. Y T z <br /> FRAMING: - SHOWER PAN (EGRESS) �085)) <br /> 6046 XO <br /> 14. VERIFY FIREPLACE STYLE t LOCATION w/5uPERv15OR PRIOR TO(ONSf. n <br /> 15. FRAMERS TO IN5TALL ALL WINDOWS t INTERIOR COLUMNS SECTION A-A 2x6 or 20 2x8 WALL SECTION A-A CPT <br /> 16. TOWEL RING BLK'G @ 57°A.F.F. (@ EXTERIOR WALL) WALL PER PLAN BACK WALL OF (@ INTERIOR WALL) �,+ HB <br /> 17. TOWEL BAR BLK'G @ 48'A.F.F.t BLOCK 6O-N E;;YS. f SHOWER,TYP. _ , <br /> I8. TOILET PAPER HOLDER BLK'G @ 22'A.F.F.,i10 42"FROM BACK WALL WHERE Fv5518LC- �^ SkOwER SOAP NICHE <br /> 2' 2'-b' I'-�° <br /> M. THERMOSTAT BLK'G @ 60'All HJ <br /> 20. EXTERIOR LIGHT BLOCKS AT ALL FRONT EN"FRY'S SHALL BE INSTALLED AT 7'-b"h.EF, SCALE:NTS O' BATH I �y Q <br /> 21. THE TOP OF THE EXTERIOR LIGHT BLOCKS AT GARAGE SHALL ALIGN WITH TOP OF FIE I 6'bxl3'8 J <br /> GARAGE DOOR TRIM ' f <br /> 22. ADD CONT.BLOCKING FOR STAIR HANDRAIL 6RaCKETS +-�- <br /> 23. STAIRS w/HINDER STEPS WILL ALWAYS HA✓E A CONTINUOJS HANDRAIL INSTALLED OA BEDROOM I I I <br /> 30'X80" Q <br /> THE SI OF THE STAIR's RUN DOUBLE RIM OR - 's �I I� 4' + W <br /> 24. LADDER-BLOCK AT EXTERIOR WALLS AS NECESSARY-OR INSULATION INSTALL I2 3x15 2 I OWB FINISHED I t <br /> PROVIDE SPLICE ,�I OPENING I TB SNu <br /> VENTILATION: <br /> 25. WHOLE HOUSE VENTILATION SHALL BE PROVIDED BY CENI RAL EXHAUST FAN IN 2" <br /> ° <br /> ACCORDANCE WITH MI505.4.1.1. OSD ; 0ATTIC I m x <br /> 26. WHOLE HOUSE FAN SHALL OPERATE CONTINJOJSLY. <br /> 27. WHOLE HOUSE FAN CFM RATE BASED ON TABLE MiS05.-3(I).EXAMPLE:70 CFM FOR 2000 L ACCESS <br /> 5F HO1E w/4 BEDROOMS,AND THEN INCREASE BY FACTOR OF I PER TABLE ADD FLAT MINI-SPLIT W/5(1) TP - <br /> 11505.4.3(2)TO ACCOUNT FOR NOT-BALANCED, NOT-DISTRIBUTED VENTILATION 575TEI1. 2X4 THROUGH r� O <br /> 28. WHOLE HOUSE FAN SHALL BE 1.0 SO'NES OR_E55,AND SHALL HAVE AN EFFICACY OF 28 JOIST @ 5'O.C. +Xb+ MINI-SPLIT 2xb WALL <br /> CFM/WATT PER WSEC R403.6.1. _ co <br /> 29. FRESH AIR SHALL BE INTRODUCED INTO THE iJOJSE`iIA OPERABLE WINDOWS PER STATE , W/S 3 U I ITV <br /> CODE INTERPRETATION 17-15. X 5'4XIO'3 <br /> 30. PROVIDE A FRESH AIR TRANSFER GRILL ABOVE O'OO,; hEADER.N THE ROOM WITH THE _ 20 Bf WNF <br /> WHOLE HOUSE FAN. HS <br /> 2'10' Y 3'8n C 3'9+ 7�_2�. <br /> 31. PER IRC M1502.4.5.:WHERE THE DRYER VENI"FXHAUST DUCT"IS CONCEALED WITHIN THE ?2868 <br /> BUILDING CONSTRUCTION,THE EQUIVALENT LENGTH OF THE EXHAUST DUCT SHALL BE STT HR5416Z. <br /> - IDENTIFIED ON A PERMANENT LABEL OR TAG. THE LABEL OR TAG SHALL BE LOCATED ATTACH TO SECTION THRU �---� <br /> WITHIN 6FT OF THE EXHAUST DUCT CONNECTION. 2X AND TO WALL CAP - <br /> o LOFT o <br /> LIFE SAFETY: STAIR RIM I? v _ 13'gx167 3z°xbo° a Z w <br /> 26. A H OUTDOOR <br /> EAT ALARM OR HEAT DETECTOR RATED FOR AJ-61EWT TEMPERATUIILs A,,D �+ c N5 48"VANITY TP <br /> HUMIDITY TO BE CENTRALLY LOCATED IN THE GARAGE. CPT HALL BATH <br /> 27. THE HEAT ALARM OR NEAT DETECTOR WILL BE CONNECTED TO AN ALARM OR 5i1OKs <br /> ALARM THAT 15 INSTALLED IN THE DWELLING AND LOCATED IN A HALLWAY,ROC41 OR 6 5'XIO'3 TB Y u e <br /> OTHER LOCATIO t N THAT WILL PROVIDE OCCUPANT NOTIFICATION tr 1--1--1 <br /> 10. SMOKE DETECTORS TO BE IIOV,INTERCONNECTED,w/BATTERY BACKUP CENTRALLY H 4�HALF WALL FRAMING CAP DETAIL El y w/5(I) <br /> LOCATED W EACH HABITABLE ROOM. ADDITIONAL SMOKE DETECTORS SHALL BE D15SCALEi _ <br /> INSTALLED WHERE THERE 15 A CEILING HEIGHT CHANGE GREATER THAN 24 <br /> V2'�I-�� SD/CO b \� <br /> 11. SMOKE DETECTORS SHALL BE INSTALLED NOT LESS THAN 3 FT HORIZONTALLY FROV! I:IE <br /> DOOR OR OPENING OF A BATHROOM THAT CONTAINS TUB OR SHOWER.IR3141 15ON <br /> 12, IONIZATION SMOKE ALARMS: SO <br /> O <br /> � SHALL NOT BE INSTALLED LESS THAN 20 FT HORIZONTALLY FROM A PERMANEWT LY IT42H HALF WALL_r; EEO <br /> )INSTALLED COOKING APPLIANCE. ~ -PROVIDE MIN.3XY ATTIC ACCESS <br /> IONIZATION SMOKE ALARMS WITH AN ALARM-5LENCING 5HIFCH 5HAL, NOT BE!HSIALLED LEARANC. SHEATHING ONLESS THAN 10 FT HORIZONTALLY FROM A PERMANENTLY INSTALLED C�CING APPLIANCE. TRUSSES MUST BE OUTSIDE OF rt EO SD24. PHOTO ELECTRIC SMOKE ALARMS SHALL NOT BE INSTALLED LE55 THAN b FT BF <br /> INSTALLED P 24'O.C. TRU55 MEMBERS sr Q COPTRIGVlT NDTICE:Tw5 <br /> HORIZONTALLY FROM A PERMANENTLY INSTALLED COOKING APPLIANCE M141 <br /> 25.GARAGE NOTE:WRAP ALL WARM WALLS AND SUPPORTING MEMBERS WITH 1/2'G.IH.L'.<t✓b" _ fT PLW:15 OWNED BY PACIFIC <br /> TYPE'X'ON THE CEILING.POLY SEAL RIM ENTIRE GARAGE TO MEET JURISDICTION Q OMEN TO b'-7° 3'-2" 3'-6' _ 6'-9' RIDGe T PAY.ElT of 7HIs <br /> � t-. BELOW RAN IS PRWIBITED BY L1W <br /> OF <br /> DRAFT STOP REQUIREMENTS LICWITENSE <br /> FEE <br /> TO P CI <br /> 26. ENCLOSED USABLE SPACE UNDER STAIRS TO BE PROTECTED WITH A GWB AT THE �S_'` sT LICENSE FEE. PACIFIC <br /> d <br /> I <br /> RID6E Hg1E5.3'12rt b'-�+WALLS, UNDER-STAIR SURFACES AND SOFFITS.27. PROVIDE FIREBLOCKING PER PLAN AND @ Al PLUY161NG PENETRATIOIJS. ' 38°H HALF �_ -' PLAN SUMMARY <br /> 5/4 TRIM GWB ATTIC "r WALL i e.+aolr m rr. <br /> OR SIM. ACCESS LID <br /> ATTIC ACCESS DETAIL ar " BEDROOM 2 BEDROOM 3 <br /> I <br /> D39 9'4x12'9' 9*1010 814 <br /> SCALE:I/2' I'-0" Ewa uv sa.rr, <br /> 1195 w <br /> - GROUT t Y 4020 PIG r200q n R, <br /> SEAL,TYP. _ <br /> `1 sn , <br /> _I SHOWER GLASS t 5046 XO(EGRESS) 5046 XO(EGRESS) 405 <br /> FRAME w/GRID PER ELEV. w/GRID PER ELEV. as nwa <br /> SLOPED TILE <br /> LAP LINE OF WALL BELOW GAS <br /> AW <br /> DRYWALL j""+`".u°`«.°wxa' <br /> 12%S,A.M., _ �+�"• <br /> BITUTNENE 3 BTL ENGINEERING <br /> OR EQUIV. 2'-7 ' 5'-0' 2'-V'�' 2'-7Y' <br /> u"siae <br /> F SEE REVISION LOG <br /> :. 2x4 STACKED �i 4 uBLOCKING AT 3'-27" 4'-0' 2'-�' SCALE: Yf=1'-0"SHOWER CURB.AT HALF <br /> WALL,FRAME 10'-0' 20'-0° _ aan moans <br /> LIKE HALF <br /> WALL.5UB FLOOR UPPER FLOOR PLAN <br /> n TILED sNowER cuRa (HALF WALL slr.)SCALE:3'-I'-0' UPPER FLOOR PLAN - 'A' It 'B' ELEV. <br /> VGV <br /> SCALE: I/4' I'-0' <br />