9554 7TH AVE SE 2024 Plans 2025-09-16
>
Address Records
>
7TH AVE SE
>
9554
>
Plans
>
9554 7TH AVE SE 2024 Plans 2025-09-16
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/16/2025 10:26:27 AM
Creation date
9/16/2025 10:24:40 AM
Metadata
Fields
Template:
Address Document
Street Name
7TH AVE SE
Street Number
9554
Permit
B2403-078
Year
2024
Notes
NEW SINGLE FAMILY HOME-RB2306-001 THELON-CHELSEA HEIGHTS 16
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
43
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL PLAIN (NOTES: <br /> I. SMOKE DETECTORS TO BE IIOV, INTERCONNECTED,W/BATTER'; <br /> BACKUP 4 CENTRALLY LOCATED IN EACH HABITABLE ROCT`I, <br /> ADDITIONAL SMOKE DETECTORS SHALL BE INSTALLED WHERE -_.. <br /> THERE IS A CEILING HEIGHT CHANGE GREATER THAN 24"(IRC R31g) <br /> 2. A COMBINATION SMOKE/CARBON MONOXIDE DETECTOR 5HA-L BE <br /> PLACED OUT5IDF OF EACH SEPARATE SLEEPING AREA IN THE <br /> IMMEDIATE VICINITY OF THE BEDROONS.(IRC R315) <br /> 3. SMOKE DETECTORS SHALL BE INSTALLED NOT LE55 THAN 5 FT <br /> HORIZONTALLY FROM THE DOOR OR OPENING OF A BATHROOM THA <br /> CONTAINS TUB OR SHOWER.(IRC R314) <br /> 4. IONIZATION SMOKE ALARMS: <br /> + SHALL ACT BE INSTALLED LESS THAN 20 FT HORIZONTALLY FROPI ` <br /> A PERMANENTLY INSTALLED COOKING APPLIANCE. <br /> + ICINIZATION SMOKE ALARMS WITH AN ALARM-SILENCING 5,17CH -- <br /> SHALL NOT BE INSTALLED LESS THAN 10 FT HORIZONTALLY FRO!`; <br /> A PERMANENTLY INSTALLED COOKING APPLIANCE. q,_61 <br /> + PHOTO ELECTRIC SMOKE ALARMS:SHALL NOT BE INSTALLED I ESS T WHFH GARAGE <br /> THAN 6 FT HORIZONTALLY FROM A PERMANENTLY <br /> INSTALLED COOKING APPLIANCE(IRC R314) plRp 5EIKTED, _(�&5. PER IRC i11507.3.2.:A LABEL SHALL BE AFFIXED TO THE NFAT LOCATION � rr 51N9t <br /> WHOLE HOUSE FAN CONTROL THAT READS"WHOLE HOUSE FAN - — tN.TtP W.. <br /> VENTILATION(SEE OPERATING INSTRUCTIONS)' <br /> 6. CEILING CAN LIGHTS OF A HABITABLE ROOM ARE TO BE INSTALLED <br /> 4 CR LESS FROM AN ADJACENT WALL 50 A CEILING FAN RATED HFATER Z <br /> JUNCTION BOX 15 NOT NECE55ARY �_ICPT r H HP \ <br /> 13A <br /> ELECTRICAL SYMBOL LEGEND D" L � _ <br /> SYMBOL DESCRIPTION <br /> SINGLE POLE 5WITCH F.F II 11Y0 RTHESE <br /> Lu f <br /> I A 1 I-INAY WITCH I R I --- 5$IFE FDY <br /> A THIS <br /> I1 <br /> 0V DUPLEX CONVENIENCE OUTLET <br /> I <br /> IIOV W CTVV CUTLET I PLEX U T,V GFI I I <br /> I <br /> 1 <br /> �t- <br /> (GROUND FAULT INTERRUPTER) I J?- t. <br /> �➢ A IS <br /> 22(N a 240V CJTLE (PER EQUIP,SPEC) . IOU <br /> KATE <br /> WP IIOV DUPLEX CUTLET WEATHER PROOF) <br /> Q� <br /> �.� (I)nw aneT f(2)u58 wrLETs - -- 1 GREAT ROOM \` <br /> BLANK PLATE I- <br /> f�1 414T IIOV DUPLEX CUTLET FOR HOT WATER TANK <br /> MF� - <br /> W HALF HOT IIOV DUPLEX CONVENIENCE OUTLET �1 A -1 DISP = HWE rTD' <br /> .._. <br /> µ <br /> 4Ca <br /> GARAGE DOOR OPENER IIOV DUPLEX OUTLET X _ I R/,N�+IE'F• <br /> (.1�'�DIN IIOV DISHWASHER OUTLET <br /> 0, 220V CLOTHES DRYER CUTLET -_ UTILITY NIP <br /> �i I KITCHEN <br /> lry CL W OTHES WASHER OUTLET i_ \- - / <br /> �� O <br /> I KT"b 220r IXfTLt-f FuR ELECTRIC C:32 CHARGER <br /> If(e RECESSED CEILING MOUNTED LIGHT FIXTUREl--1— <br /> CEILING MOUNTED LGM MATURE / ® -__ ` •. O Ol O -_.. --. _R <br /> FENDANT LIGHT FIX-URE 1 J o I <br /> L-91 <br /> WALL MOUNTED LIGHT FIMRE ONT,1 EXT, _____ FIREPLACE OPT. <br /> ' HINT TO BE > <br /> �v FLUORESCENT FIXTURE HALL BATH INSTALLED � I II B <br /> IN THE 3Td <br /> SCALE;Y' <br /> IOV -lp <br /> m ue <br /> 1. -- - � � <br /> L � PORCELAIN KEYLESS LIGHT F'XTI:RE � �- � X R , <br /> CAR --A� +_% GARAGE OR p � p <br /> ' - _ ......._.__ Y_�al <br /> I 5MOKE DETECTOR, LV dATTERT BACKUP —_ -_ <br /> -. BUMP-OUT <br /> 7eo c +srlcKE DETECTOR GARAGE <br /> Ai_AR <br /> Sl NEAT 5EDDETECTOR/MOUNTED <br /> \ �THAT <br /> - _.._. .._ O \ I KEYLFY -' KErtrss SELECTED. <br /> RECESSED CEILING MOUNTED FAN,V.T.O. <br /> kIv IJHOLE HOUSE FAN <br /> WHOLE HOUSE FAN TIMER CONTROL \ co <br /> \ <br /> y MOUNTED <br /> - WALL HEATING E COOJIY UNIT(MINI-SPLIT) N <br /> ELECTk1CAL CEILING F.A ER STACKPD WTA(i➢P) GARAGE <br /> JACK I&LWI P.9E FOR.. <br /> FLIT] THERMOSTAT �`�`BI,VX BATE I � _ / ! � / <br /> J <br /> f TD7J COMBO RG'c w/(2)CATvE <br /> D/P COMBO JACK WITH(2)CAT5E <br /> L "fELEPIapIF JACK <br /> f1T nai 5MURF TUBE OR EQUIVALENT J C/VI N d - YER W5 <br /> lu <br /> HOME AUTOMATION CONTROLS COPYRIGHT NOTICE:THIS <br /> BEDROOM 3/ J� z _ _ <br /> -{Tr � UP TO3 PLAN 15 OWNED BY PACIFIC <br /> A/C WP FRE-A/C OR HEAT PUMP 'I B I I _ CARS 3 FOR RIDGE NCMIES.USE OF THIS <br /> V DOOR BELL -K— BEDROOM 2 ---- - LAYOUTLrFY, <br /> WITHOUT FEE <br /> TENT CI <br /> II` PLAN 15 PRCNIBITED BY LO <br /> ICJ FLAT PANEL PRE-WIRE d SEE K5, LICENSE FEE. PACIFIC <br /> SURROUND SOUND SPEAKER O,� SEE W$/ILA RIDGE HOMES. <br /> PLAN SUMMARY <br /> e ---- a m• CENTER ALL LIGHT FIXNRES ON -_ I - <br /> YANITT 31NK(5). <br /> LIGHT FIXTURES OVER VANITIES <br /> TO BE 52'-U'F.F. <br /> REFER 10 CABINET LAYOUTS FOR B <br /> KITCHEN <br /> APPLIANCE AND VANITY N� y�uvu m B <br /> CENTERLINE LOCATIONS. <br /> FLOOR ELECTRICAL PLAN MAIN FLOOR ELECTRICAL PLAN 405 n� <br /> (ALL ELEV'S SIM.� GAS <br /> (ALL ELEV'S SIM� <br /> SCALE; 1/4'•I'-0' SGALE:Y'=I'-0' JWA <br /> BTL ENGINEERING <br /> MAIN FLOOR ELECTRICAL PLAN: SEE REVISION LOG <br /> z3IEXT. FRONT PORCH OPT. SCALE: y7=P_0:, <br /> SCALE:Y' <br /> ELECTRICAL PLAN5 <br /> >7 <br />