Laserfiche WebLink
SELF ADHESIVE /�_ - PER =ti <br /> MEMBRANE PAN --- !I.�;,L>. - .;CIS EXTEND MIN.b'UP JAMB -, <br /> FLASHING- 11 / NIL <br /> NAIL it L,kiELE / i--__ �,- __,i,.,,_, NERVASTRAL TO EXTEND <br /> FLASHING --- -:F 2'PAST THE INTERIOR L <br /> / -- RLI OF THE DOOR \ HEADER/ \ HEADER/ <br /> FLOOR JOIST \ i % / IC EkEFI STLii <br /> PER PLap.- A - �' �_ Lc-+:- I <br /> _ __/ _ F_2 h_�, ha1L: ROUGH ROUGH <br /> OPENING OPENING <br /> y BAF I,: <br /> _ JAMB\ �. JAMO <br /> a ,, I_ rJ-, COI Il 2ND Sce / SILL \ SILL <br /> IV <br /> \ <br /> PI' <br /> INS... - <br /> IN EK FI <br /> RIM JOIST r-_. - _.-.. L cR COI f..: 15 PENETRATION j 6° <br /> BUILDING WAFER T P/fCE �� SILL <br /> SHEATHING-P. ram,: <br /> INSTA ED BEAIN- FLASHING <br /> LEDGER AHD PA`. - -FIRING PER I P_:, BUILDING PAPER TO EXTEND ATTACH <br /> FLA I-N AP ED EE MIN.12"BEYOND ALL EDGES I _ <br /> OVER I,CLSE WRAP LEDGER G A C._ STEP STEP 2 <br /> �./SOLDlNG P:+FER BE II - _ EXTEND 12"BEYOND - OF THE PENETRATION SILL STRIP OF 9'WIDE M015TOP(OR EQ.)FLASHING MATERIAL •ATTACH JAMB STRIPS OF 9"WIDE M015TOP(OR EQJ. j <br /> EXPOSED ON ALA 4 SJ_ OPENING •WITH THE TOP EDGE EVEN WITH THE TOP OF THE ROUGH SILL. FLASHING MATERIAL WITH IN51DE EWE EVEN WITH THE JAMB 1 <br /> -- •EXTEND T1415 STRIP AT LEAST 12"BEYOND THE EDGE OF THE ROUGH OF THE ROUGH OPENING. <br /> OPENING. •START JAMB STRIPS 2"BELOW SILL STRIP AND EXTEND 6" <br /> TECH LEDGER DETAIL FLASHING EXTERIOR DOOR FLASHING PENETRATION PROTECTION ATTACH FLASHING MATERIAL WITH CORROSION-RESISTANT STAPLES. ABOVE LOWER EWE OF HEADER. <br /> CID <br /> v,J N.Ts_ W I6) - - W 15 SCALE:N.T.S. W I q SCALE:N.T.S. <br /> ND 0Fain caR i wER.a� coat.BEAD of <br /> IT// <br /> SEALANT <br /> EQ. EQ. UNDER NAIL FIN ■ <br /> 5GD PER PLAN 2° <br /> �j i� IWFRABLE� FIXED CUT AWAY <br /> l PANEL I PANEL <br /> __._—_-EXCESS HINCOW <br /> LINE Of - BLW.PAPER FRAME OR <br /> __ ____ <br /> NERVESTRAL -- 36 IIrEAARTW00D CEDAR TRIM, l <br /> }. BEHIND I E0.ALL SIDES,CAULK/SEAL OPENING SIMILAR <br /> b TO HCFE BIBS EQ, .ic EQ OPENINGFO eka uNDI'w nP *NOTE: SEAL ALLOF 1 I BUILDINGC.L OF NERVASTRAL D(POSED FASTENERS BEND FRONT PORCH PATIO BUILDINv PAPER <br /> _ ELECT R!LA_ 3'-6'LANDING TYP. SHEATHING PER PLAN PA ER TYP. (� <br /> METER I'IA'.N e.•a PATIO'•sww!.0 wars \\\\\\\ <br /> 0. P BACK PATIO's vo"�n N TME a"�TK" INSULATION BLW PAPER �.IL <br /> OFBUILDING PAPERGE UNDER SILL STRIP <br /> R _ �_ DOOR xLANDING PER PLAN. n ..� � � ( ) ••AAPPLY A 3/8'CONTINUOUS BEAD OF CAULK TO THE BACK OF THE FRAME SA <br /> C® PRONTO BENE PER PLAN APPROVED FLASHING <br /> LP INSTALLED U71 O.Iq x IO°ROLL S <br /> EXTOF HOC.," THRESFbLD RAMS THE NEXT COURSE E BUILDING PAPER(BUTTING 70 THE <br /> �r HUf � E AGAINST NERVESTRAL �e uEARTwcoD CEDAR ` SIDING PER PLAN 1-I/2"GAP NAILING FLANGE AT ALL SIDES OF THE WINDOW FRAME OPENING)OVER THE JAMB FLASHING MATERIAL. <br /> ;T ..R.L,E HOSE 304 rELI F.r... -.- ----- HOUSE <br /> wi FLASHPIG a ice, BTWN RWF AND SIDING •PLACE AND SECURE FRAME INTO ROUGH OPENING WITH FLANGES OVER THE •APPLY SUCCEEDING LAYERS OF BUILDING PAPER III SHINGLE <br /> ' I '� BIBB NERVESTR4L —_T HOUSE INTERSECTi N, —��J — <br /> STARTLF f�di LAND11 PER y WHERE OCCURS INSTALLED JAMB AND SILL 4 JAMB M015TOP(OR EQ.)FLASHING MATERIAL BOARD FASHION UP THE WALL, LAPPING COURSES A MINIMUM OF <br /> INSTALL (MN a',TrP � �/! ROOF SHINGLES •NAIL WINDOWS PER WINDOW MANUFACTURERS SPECIFIC v2 PAPER WIDTH. <br /> - _ *OF STEPS TED by UNE OF NERVESTRAL � •STARTING FROM THE BA5E OF THE WALL,APPLY BUILDING PAPER UNDER <br /> ROD 12".I:U rLASHI\. - MUD SILL IiE G'tRi1'i cNs IFE�T MIN EXPEND UP THE SILL STRIP AND CUT ANY EXCESS BUILDING PAPER THAT MAY EXTEND <br /> ROD I� 'RiJ1 --_____ _ <br /> PRONTO BEi"- -- CCNC wAu SLAB ON GRADE ABOVE THE SILL AND BETWEEN THE JAMBS OF THE OPENING. �--- <br /> [AN- k •ADD FORTIFLA%STICK FLASHING N BOTH SIDES OF WINDOW <br /> FORT FLASH <br /> r F L a l s¢ux rcR Fir oax <br /> I� .DY PI-AN- '. ROOF TRUSS ; � •APPLY SLOPED 28 GA..2"BACK,PREFNSHED METAL FLASHING TO OPENING. <br /> A4D MOIST Fl,..r - ''�FAx+r Pwa°ET"A ROOF SHEATHING PER PLAN •APPLY 6°FORTIFLASH OVER TOP HEAD FLANGE OF WINDOW_EXTEND PAST <br /> LLFOI SIDE I TN L I u L, e - '�� la l r EXT. LANDING DETAIL @ ROOF TRUSS JAMB FLASHING 2'. 1'<aLL SIDES e vRFJE ' r � pp <br /> TRIM PER"1LT R h @SAVE SLIDING GLASS DOOR TYP ROOF TB WALL _FLASHING @ STANDARD FLASHING MATERIAL APPLICATION AT OPENINGS <br /> FLNI JC FOR E-EC-- -�� --- \W I J I "I W I L SCALE:N.T.S. W I I SCALE:N.T.5. W I O SCALE:N.T.S. <br /> METER BOX,FIREPLACE 'L <br /> E , <br /> iAREC" ENT RANG VENT, E . - - <br /> II R'/ENT ETC. SEALANT WINDOW FRAME CID7/16"PLYWD SHEATHINU <br /> *SEE DETAIL AID FOR I'OSTOP IN5!r__IiI I.. 318"BEAD CAULK INSULATION <br /> /' �'1 SILL ASSEMBLY <br /> ELECTRIC RC METER HOSE DPI-. PER SPEC— ��SEALANT (WHERE 0,'.LURS)- 6' FORTIFLA5H 0/FLASHING <br /> .___. <br /> TRIM PER ELEVATION GYP.BD. WD,FRAME WALL SIDING PER PLAN <br /> ` (WHERE APPLICABLE) INSULATION PER PLAN--- ---- ' -BUILDING PAPER <br /> r C' LOCATION NO GAS METER (WHERE OCCURS) <br /> l I/VJ SCALE!N-_5--`- �- TRIMMER En <br /> R-10 INSULATION - -MOISTOP(SEE DETAIL WIIO <br /> MOISTOP(SEE DETAIL KING STUD- BEHIND HDR,TYP @ FOR INSTALL) <br /> WIO FOR INSTALL) ND.FRAME WALL ALL HDR's MW. /4"GAP BTWN SIDING <br /> SEALANT PER PLAN I 1 % AND FLASHING COFYRQAT NOTICE:THIS <br /> .. 'MIN.18° EXT WALL PER FORTIFLASH ON ALL GYP.BU. -- `_1 <br /> M015TOP(SEE �.,\ PLAN IS OVNED By PACIFIC <br /> PLAN SIDES OF WINDOW - �•-FLASHING TURN DOWN RIDGE HOMES.USE OF THIS <br /> , •- DETAIL WO 7/Ib"PLYWD.SHEATHING HEADER PER PLAN-- /4'AT EACH END PLAN is PROHIBITED Br LAW <br /> SIDING PER PLAN FOR INSTALL)\;' -- it LICENSE FEETTONPACIFIC <br /> INSULATION WINDOW FRAME ---TRIM PER ELEVATION I RIME HOMES <br /> % BLDG.PAPER SEALANT - ( (WHERE APPLICABLE) / <br /> WHERE OCCURS BLDG.PAPER <br /> AFER TYP. ( ) SEE ELEV.FOR <br /> 'ER PLAN 7/I6'PLYWD.514EATWING SIDING PER PLAN ) \ / <br /> I0 6 O HOSE BIB WINDOW HT \ <br /> ___... .. <br /> 8'- T .L ; TRIM PER ELEVATION / -SEALANT �. PLAN SUP1r'1AR'" <br /> 'LED TRIM (WHERE APPLICABLE) FORTIFLASH ON ALL SEALANT ,oua:�cameuea,rmn. <br /> eD,E TO_PRON O BED D I _.- <br /> --- -- SIDES OF WINDOW WINDOW FRAME <br /> 3 SEND:, <br /> Wq 1 )RNER WS WINDOW SILL WOOD FRAME WALL S WINDOW JAMB DETAIL r'` WINDOW HEAD DETAIL � .1 <br /> EDGE - E '( `J/ SCALE:N.T.S. SCALE:N.T.S. W6 � <br /> 1 Id SCALE.N.T.S. <br /> 11g5 <br /> --STUDS 0 I6"a(NO POSTS/ 2009 <br /> tF <br /> LAP SIDING,U NR (HOLD I-I/2' POINT LOADS ABOVE VENTS) <br /> ..f R-L i E 'LAG SCREW OFF ADJOINING ROOF) :, <br /> I _ ED METAL FLASHING SIDING PER PLAN -� 405 <br /> . GAS STUDS. (MAY BE STEPPED) /t'J/ BOTTOM SILL PLATE— 1FAT'0�' <br /> iyjj, METER - i' �� <br /> - _ ?PENETRATE BUILDING PAPER ON = _,-3/4"TfG SUBFLOOR __ <br /> � GAS <br /> SHEATHING(SIDING CUT FLASHING JWA <br /> V - MIN.,TYP.F i�-"- _.a.lr-. S � •wa vmwurm. <br /> .. ND 29 HT OF AWAY FOR CLARITY) 7-1/_x15-1/2'CEDAR RIM <br /> K- LA ,'F-_,tS-I.NG TA,',FI w/13/B' <br /> L MOI TOr.TURN STRAP MIN METAL RAIN DIVERTER(THE o VENTS w/GALV SCREEN- <br /> PURPOSE 15 TO SHED THE PROVIDE LOUVERED VENTS BTLENGINEERING <br /> .I,01 5T I'ONTO P.+IILL� - <br /> -__SIDES c CORNERS. AT HWT WATER OFF THE ROOF AND \ 0 FRONT ELEVATIONS <br /> -_ !C KEEP IT AWAY FROM THE j ROOF SHINGLES --RIM PER PLAN _ SEE REVISION LW <br /> '42 TRIM Cn PERIMETER-- VERTICAL WALL BENEATH), PER SPEC. <br /> '!J!i. IT OF HWT FASCIA PER PLAN w/ �- P.T.MUD SILL -__-' - SCALE, V=I:-0" <br /> C•FENING FOR EEEC, ti - /� ' 30#ROOF FELT CONCRETE FOUNDATION <br /> METER BOX,FIREPLACE GUTTER <br /> DIRECT VENT, RANGE VENT, METF,j 7/I6"OSB ROOF *$DO NOT INSTALL VENT(5)CLOSER THAN3'TO GAS METER++ WATER <br /> DRYER VENT, ETC SHEATHING -*BUILDING PAPER SHOULD BE INSTALLED OVER FLASHING,-.." INTRUSION <br /> NOTE:PER WSEC R40227 WHEN FOUNDATON VENTS ARE NOT PLACED Sli"THAT THE TOPx• DETAILS <br /> +SEE DETAIL n10 FOR C0ISTGP INSTA�_L OUST E OF THE VENT 15 BELOW THE LOWER SURFACE OF THE FLOOR INSULATION,A PERMANENTLY <br /> T r #NOTE: SEAL ALL (ATTACHED BAFFLE SHALL BE INSTALLED AT AN ANGLE OF 30•FROMHORIZONTAL,TO N.P�z <br /> ELECTRIC lHA METER: N USE 3 STRAPS ON 75 GALLON AND GREATER SIZES EXPOSED FASTENERS DIVERT AIR FLOW BELOW THE LOWER SURFACE OF THE FLOOR IASULATI. <br /> BIB CLE.\RANCE' LOCA I I;N-, WATER NEATER (NWT) STRAPS DETAIL @ ROOF/WALL INTERSECTION � FOUNDATION VENT <br /> \W� SCALE-U.T.S. -- SCALE:N.T.S. YVL .SALE:N.T.S. WI SCALE:N.T.S. - <br />