Laserfiche WebLink
SLIDING GLA55 DOOR <br /> SELF ADHESIVE PER P-AN <br /> MEMBRANE PAN SLIDING GLASS DOOR EXTEND MIN.6'UP JAMB p�s1Yryi, <br /> NAIL ON FLEXIBLE FLANGE <br /> >rAyy FLASHING /� NAIL F I <br /> - \ / -GALJ Z FL._aINI; OF THE <br /> TO EXTEND <br /> FLASHING - , / -2"I-I Ie FROM'i;P OF 2'PAST THE INTERIOR \ HEADER/ \ HEADER/ <br /> L J015 LEDGER TD:-.6 SCREW _ OF THE DOORFLOOR T STCC <br /> PER,PLAN -� 5/4a4 CEDAR=t::.IWG ROUGH ROUGH <br /> PER PLAN KATE�RE b;I i. OPENING OPENING <br /> 'l BARRIER .... <br /> -t_ix P GS ,TER PLAN <br /> -71 JAMB\ JAAMB\ <br /> -HAND i En LAN J 1 f t �alii., ?ND PIECE / SILL <br /> - INS,LL FLAW', <br /> NODER <br /> RIM JOIST "� _SHEATHING PCR PL LEDGER PcIi P_ti:a CONTAC ATE _ IST PIECE. 12' PENETRATIONS" <br /> BUILDING PAPER SILL <br /> INSTALLED BEHIND SIDIiNG,FER FLASHING <br /> LEDGER AND PAN --SIDING PER PLAN PLAN <br /> �' BUILDING PAPER TO EXTEND <br /> FLASHING.LAP ' <br /> OVER HOUSE WRAP /•LEDGER INSTALLED 6EFCRE SIDING MIN,12'BEYOND ALL EDGES STEP I 2 <br /> w/BUILDING PAPER BEHIN'C iT m-L EXTEND 2 BEYOND - OF THE PENETRATION .ATTACH SILL STRIP OF q'WIDE M015TOP(OR EQ.)FLASHING MATERIAL ATTACH JAMB STRIPS OF q'WIDE MOISTOP OR EG.). <br /> EXPOSED ON ALL 4 SIDES OPENING WITH THE TOP EDGE EVEN WITH THE TOP OF THE ROUGH SILL. FLASHING MATERIAL WITH INSIDE EDGE EVEN(HIT14 THE JAMB �d <br /> --- •EXTEND THIS STRIP AT LEAST 12"BEYOND THE EDGE OF THE ROUGH OF THE ROUGH OPENING. <br /> FLASHING START JAMB STRIPS 2'BELOW SILL STRIP AND EXTEND 6' _ <br /> DECK LEDGER DETAIL SIDIINT I;II �ZXTERIOR DOOR FLASHING n <br /> 7 -- -----.--- ..-...__ � -__ '" LIIC 1.11 A PENETRATION PROTECTION •ATTACH FLASHING MATERIAL WITH CORROSION-RESISTANT STAPLES. ABOVE LOWER EDGE OF HEADER CID <br /> y-1 <br /> W_2' (W16.." lJ 1�� N.T.S. SCALt IJ.i,S YVIJ EC.4LE:N.T.S. YV I'i SCALE:N.T.S. n/ <br /> cwrex rain i a �i CONT.BEAD OF 1 • 1 <br /> SEALANT <br /> EO10E� EQ. FLASHING �-1-t <br /> UNDER NAIL FIN <br /> SGD PER PLAN 2' 2" <br /> OPERABLEI FIXED Q �- <br /> NERVESTRAL ` -��---- &6 JNEARTWCCD CEDAR TRIM, __ �RAIOR LUT AWAY <br /> PANELPANELLINE OF __________ __ _ _ EXCESS WINDOWBLDG.PAPER FRAME OR <br /> BEHIND ED.ALL SIDES,LAULr�sEAL AR I I'� B OPENING SIMILARE BIB E0. kEEO NG 1 1'. OPENING <br /> 3'-b'TO 5B TTOOI OF �l ---SI,V LANDING nP. ANOTE: SEAL ALL -- v <br /> C.L.OF NG <br /> I PaR AGAwsr BUILDING <br /> PRONTO NERvas RAL EXPOSED FASTENERS <br /> BEND FRONT PORCH PATIO BUILDING PAPER <br /> ELECTRICAL 31-6'LANDING TYP. SHEATHING PER PLAN PAPER <br /> YR R TYP. <br /> sex rendaxcmo ewers BLDG PAPER LINE OF BUILDING PAPER <br /> METER MAIN B BACK PATIO'S g <br /> . rnAso w TMe mFscre.N INSULATION <br /> % ' a nrz Nxm s,oe a rue � NAIL FLANGE UNDER SILL STRIP <br /> ® s.e.D.wauveR rcevns PER PLAN _. <br /> PRONTO BEOL' APPROVED FLASHING STEP 3 STEP 4 <br /> FRONT - �(.NEARTWWD CEDAR TRIM <br /> INSTALLED ON DOOR -`Ir (O.Iq x 10'ROLL) •APPLY A US CONTINUOUS BEAD OF CAULK TO THE BACK OF THE FRAME APPLY THE NEXT COURSE OF BUILDING PAPER BUTTING TO THE <br /> CORNER �, LANDING PER PLAN Pg1R <br /> �'- .OF HOUSE TM+F51OLD AGAINST NERVESTRu • ( \ <br /> OF HOUSE a,b NURTwoDD CEDAR �.,� SIDING PER PLAN I-I/2"GAP NAILING FLANGE AT ALL SIDES OF THE WINDOW FRAME OPENING)OVER THE JAMB FLASHING MATERIAL <br /> AT GARAGE % _HOSE 304 FEL1 �eI C: ---- ------ Twn,w FuSECTI o - BTWN ROOF AND SIDING •PLACE AND SECURE FRAME INTO ROUGH OPENING WITH FLANGES OVER THE .APPLY SUCCEEDING LAYERS OF BUILDING PAPER IN SHINGLE co'��J <br /> NFRVESTRAL HLVSE INTERSECTION, --,,�I -- <br /> '--BIBS STARTEf. JF. LAiIDIN/-PER PLAN _ _ WERE OCCURS INSTALLED JAMB AND SILL t JAMB MOISTOP(OR E0.)FLASHING MATERIAL. BOARD FASHION UP THE WALL,LAPPING COURSES A MINIMUM OF <br /> INSTALL (MM 3',ttP/ /_ I ROOF SHINGLES •NAIL WINDOWS PER WINDOW MANUFACTURER'S SPECIFICATIONS 1/2 PAPER WIDTH. 1 <br /> __ *ah STEPS-BD BY `-- LINE OF NERVESTRAL •STARTING FROM THE BASE OF THE WALL,APPLY BUILDING PAPER UNDER <br /> ROD 12" G ^ MUD SILL sltE cDNDrilals 308 FELT TO EXTEND UP THE SILL STRIP AND CUT ANY EXCESS BUILDING PAPER THAT MAY EXTEND <br /> GROUNDING - _SLAB ON <br /> GRADE WALL I2"MIN. ABOVE THE SILL AND BETWEEN THE JAMBS OF THE OPENING. <br /> _ <br /> FORTIFLASH d/FLASHING GUTTER •ADD FORTIFLA5H STICK FLASHING N BOTH SIDES OF WINDOW \' <br /> FL HI\. <br /> PRONTO BENG LCNc,w+u <br /> PLAN -.t:. °°0 f0R" e°0R •APPLY SLOPED 25 GA 2'BACK,PREFIN15HED METAL FLASHING TO OPENING. <br /> AND MOISTOP TURN - - q Mt,.;TOr FASCIA PER r'I,;a ROOF TRUSS EXT. LAN. Nn rRaT Para OL(A0. ROOF SHEATHING PER PLAN •APPLY 6'FORTIFLASH OVER TOP HEAD FLANGE OF WINDOW.EXTEND PAST <br /> Y�L <br /> ALLFOR SIDES <br /> f ONTO PANEL, DING DETAIL @ ROOF TRUSS <br /> ALL SIDES t CORNERS JAMB FLASHING 2". � ��-AV <br /> FTYPLAbhNG L-,�rl�l _ @ EAVE , Y ROOF TO WALL FLASHING STANDARD FLASHING MATERIAL APPLICATION AT OPENINGS 4 <br /> 2x2 TRIM Ii PERIMETER FLA r� - SLIDING GLASS DOOR TYP <br /> OPENING FOR ELEC.- 60 MIN.BLDG W13 „LAIC N._..S W12 SCALE,N.T.S. WII SCALE:N.T.S. WIO SCALE,N.T.S. <br /> METER BOX, FIREPLACE PAPER BEHIII p DIRECT VENT, RANGE VENT, METER MAIN SEALANT ,F�(�, <br /> DRYER VENT, ETC. WINDOW FRAME —7/16"PLYWD.SHEATHING c Y y <br /> "SEE DETAIL HID FOR MOISTOP INSTALL INSTRUCTIONS 3/8'BEAD CAULK I(WHERE IOOCCURS) %- 6'FORTIFLASH 0/FLASHING <br /> M SILL ASSEMBLY _ <br /> ELECTRIC METER 4 HOSE &B PER SPEC-- _. SEALANT GYP.BD. WD.FRAME WALL SIDING PER PLAN <br /> Q. TRIM PER ELEVATION /-J <br /> ., <br /> Q LOCATION (NO GAS METER) (WHERE APPLICABLE) INSULATION PER PLAN---- -- �BUILDING PAPER <br /> TRIMMER (WHERE OCCURS) R-10 INSULATION---- -- MOISTOP(5EE DETAIL WHO <br /> SCALE:N.T.S. MOISTOP SEE DETAIL <br /> GTP.BD. ( KING STUD BEHIND HDR,TYP FOR INSTALL) <br /> WIO FOR INSTALL) WD.FRAME WALL ALL HDR's THIS <br /> /-MIN.1/4'GAP BTWN SIDING <br /> SEALANT PER PLAN FLASHING cDPTRIGNr NI'MIN.IB" EXT WALL PER FORTIFLASH ON ALL GYP,BD. AND <br /> ---- -FLASHING TURN DOWN RIDGE HOMES USE OF THIS <br /> PLAN SIDES OF WINDOW MOISTOP(SEE j "'�� PLAN IS OWNED By PACIFIC <br /> DETAIL W10 = HEADER PER PLAN 1/4'AT EACH END—�` <br /> FOR INSTALL) 7/I6'PLYWD.SHEATHING PUN Is PRaNIBITED BY Uw <br /> SIDING PER PLAN Wnuarr PAYMENT of <br /> INSULATION WINDOW FRAME TRIM PER ELEVATION LICENSE FEE TO PACIFIC <br /> r WHERE OCCURS BLDG PAPER BLDG.PAPER RIDGE HOMES. <br /> i APER TYP. ( ) SEALANT SEE ELEV.FOR (WHERE APPLICABLE) <br /> ,.� 10'-6'TO HOSE BIB 'ER PLAN ;' SIDING PER PLAN WINDOW HT) <br /> - --------- ----- : 7/16"PLYWD.SHEATHING TRIM PER ELEVATION SEALANT PLAN SUMMARY <br /> ( 9ED TRIM ' (WHERE APPLICABLE) FORTIFLASH ON ALL SEALANT �� <br /> EDGE B'-6°TO SE ux"m urn us•eRrrtnrr. <br /> EDGE PRONTO BEND - ry SIDES OF WINDOW —/ --WINDOW FRAME <br /> EDGE wQ1 Jl /Ild )RNER WS WINDOW SILL @WOOD FRAME WALL WT WINDOW JAMB DETAIL hi6 WINDOW HEAD DETAIL �R, <br /> TO J <br /> _ ELECI Kl:w IL �caLt J T �J SCALE:N.T.S. /� 814 J SCALE,N.T.S, SCALE:N.T.S. <br /> 1 '�ETER�IAr,J my urn sa rt, <br /> ® / <br /> °RCfITf BE:N:; 1195 <br /> FRONT-- ''NSTALED ON -STUDS F 16"oc NO POSTS/ rora.uwm a, <br /> i <br /> CORNER EXT,O-r HGUSE ,� ( 2009 <br /> OF HOUSE -%"r - LAP SIDING,U.NO.(HOLD I-I/2" ABOVE VENTS) <br /> OFF ADJOINING ROOF) .%'i POINT LOADS - wrceAw ea.rr., <br /> ; <br /> AT GARAGE 505E "LAG SCREW i x SIDING PER PLAN-� 405 <br /> CAS ��.6188 METAL FLASHING <br /> _Y ATTACHED x <br /> METER INSTAL,- .STUDS.LAG (MAY BE STEPPED) ,-t �`--EO—+' BOTTOM SILL PLATE 'uAT S <br /> -`_ UROUNCI.J o PENETRATE BUILDING PAPER ON 3/4"T{G SUBFLOOR _ GAS <br /> COD 12 F'O`1 111N.,TYP.P SHEATHING(51DING CUT I,I : <br /> PRONTi LEND JD 2/3 HT OF AWAY FOR CLARITY) `8 ii ii FLASHING JWp <br /> FORTIFLA,H d/FLASHING TACH w/I W T- 7-1/2'X16/1/2'CEDAR RIM S <br /> FOR MOISTOP,TURN— "q'NCISTOP a.STRAP MIN METAL RAIN DIVERTER(THE VENTS w/GALV SCREEN- <br /> I I BTL ENGINEERING <br /> FJRTiFLASH I"ONTO PANEL, j PURPOSE IS TO SHED THE PROVIDE LOUVERED VENTS <br /> ALL SIDES t CORNERS. HT HINT WATER OFF THE ROOF AND a FRONT ELEVATIONS—' Pf111p1' <br /> FLASHING KEEP IT AWAY FROM THE ;-%,,.: ROOF SHINGLES -RIM PER PLAN � SEE REVISION LOG <br /> 2X2 TRIM N PERIMETER - IYR VERTICAL WALL BENEATH), xaRw u <br /> OPENING FOR ELEC- - 60 MIN.BLr,G IT OF HINT FASCIA PER PLAN w/ P.T.MUD SILL--�� SCALE: Y"-P-0" <br /> 301t ROOF FELT CONCRETE FOUNDATION <br /> METER BOX, FIREPLACE _�__ PAPER BEWWD GUTTER fQA°°s' <br /> DIRECT VENT, RANGE VENT, METER MAIN 7/16"OSB ROOF $$DO NOT INSTALL VENT(S)CLOSER THAN 3'TO GAS METER$$ WATER <br /> DRYER VENT, ETC. SHEATHING '$BUILDING PAPER SHOULD BE INSTALLED OVER FLASHING" INTRUSION <br /> NOTE:PER WSEC R402.2.7:WHEN FOUNDATION VENTS ARE NOT PLACED 50 THAT THE TOP DETAILS <br /> r SEE DETAIL w10k FOR MDSTOP INSTALL INSTRUGICNS {NOTE: SEAL ALL OF THE VENT IS BELOW THE LOWER SURFACE OF THE FLOOR INSULATION,A PERMANENTLY <br /> ELECTRIC GAS METER HCI:iE ATTACHED BAFFLE SHALL BE INSTALLED AT AN ANGLE OF 30'FROM HORIZONTAL,TO <br /> I USE 3 STRAPS ON 75 GALLON AND GREATER 51ZES EXPOSED FASTENERS DNERT AIR FLOW BELOW THE LOWER SURFACE OF THE FLOOR INSULATION <br /> WF 13 BCA CLEARANCES It LOCATIONS WATER HEATER (HINT) STRAPS W2 DETAIL @ ROOF/WALL INTERSECTION FOUNDATION VENT <br /> SLE:N.TS. SCALE:N.T.S. SCALE:N.T.S. SCALE:N.T.S. f"1 <br />