My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6715 HIGHLAND DR 2025-09-30
>
Address Records
>
HIGHLAND DR
>
6715
>
6715 HIGHLAND DR 2025-09-30
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/30/2025 9:13:19 AM
Creation date
9/16/2025 11:08:17 AM
Metadata
Fields
Template:
Address Document
Street Name
HIGHLAND DR
Street Number
6715
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
55
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
u IScrew <br /> Ledger-to-Stud Applications I 1 <br /> Strong-Drive SDWS Timber screws may be used to attach a ledger to the narrow face of <br /> nominal 2x lumber studs according to the following table. Values are based on assembly tests <br /> with analysis performed in accordance with ICC-ES AC233. <br /> Allowable Shear Values for Ledger Attachment to Studs <br /> Nominal able Shear ... , <br /> Length Ledger Number of <br /> Model (in.) Size Screws per SPF/HF SP <br /> Shid kii <br /> 2x6 2 630 565 785 <br /> SDWS224000B 4 2x8 3 890 1 <br /> 2x10 4 1,040 1,040 — <br /> 1.Allowable loads shall be limited to parallel to-grain-loaded 5.Screws may be installed with an intermediate layer of wood <br /> lumber studs(minimum 2"nominal).Wood ledgers shall be structural panel between the ledger and stud provided the <br /> loaded perpendicular to grain. wood structural panel is fastened to the stud per code and <br /> 2.Allowable loads are based on DF,SPFMF,and SP wood the minimum screw penetration of 21h"into the main member <br /> members having a minimum specific gravity of 0.50,0.42 and (excluding the wood structural panel)is met.Longer lengths of <br /> 0.55,respectively.Where the ledgers and studs have different the screw series may be used. <br /> specific gravities,the lower values shall be used. 6.For LRFD values,the reference connection design values shall <br /> 3.Allowable loads are shown at the wood bad duration factor be adjusted in accordance with the NDS,section 11.3. <br /> Of CD=1.00.Loads may be increased for load duration as 7.For 2x10 SP ledgers,use the number of screws and allowable <br /> permitted by the building code up to a CD=1.60. bads of the 2)(8 SP ledger. <br /> All adjustment factors shall be applied per the 2018 National 8.For 2x8 ledgers with two screws,use 2x6 values.For 2x10 <br /> Design Specification(NDS).For in-service moisture content ledgers with three screws,use 2x8 values.Spacings and edge <br /> greater than 19%,use CM=0.70. distances shown in the figure are minimum dimensions. <br /> 4.Fasteners shall be centered in the stud and spaced as shown 9.For bads in the opposite direction from that shown in the <br /> in the figure.The stud minimum end distance is 6"when figure,use the table values multiplied by:0.50 for two-screw <br /> loaded toward the end and 21/z"when loaded away from the connections,0.67 for three-screw connections,and 0.75 for <br /> end.The ledger end distance is 6"for full values.For ledger four-screw connections. <br /> end distances between 2"and 6",use 50%of the table bads. <br /> For end distances between 2"and 4",predrill using a Y�"bit <br /> for SDWS. <br /> 2x atud 2x stud 2x stud <br /> 2x6ledger A 2x8ledger 2x101edger <br /> T <br /> o� <br /> 17/16 17/16' 1�/I6' U <br /> F <br /> m <br /> 31/2 j' 2 s/s" 27/w e <br /> Co <br /> T t ' 27/16' E <br /> /is" 2 � <br /> Load T � <br /> direction L 16 v� <br /> Load o <br /> direction <br /> Load LL <br /> &echon <br />
The URL can be used to link to this page
Your browser does not support the video tag.