101031833 <br /> BUILDING PLANNING <br /> R301.4 Dead load. The actual weights of materials and R301.7 Deflection. The allowable deflection of any struc- <br /> construction shall be used for determining dead load with tural member under the live load listed in Sections R301.5 <br /> consideration for the dead load of fixed service equipment. and R301.6 or wind loads determined by Section R301.2.1 <br /> R301.5 Live load. The minimum uniformly distributed live shall not exceed the values in Table R301.7. <br /> load shall be as provided in Table R301.5. R301.8 Nominal sizes.For the purposes of this code,dimen- <br /> R301.6 Roof load. The roof shall be designed for the live sions of lumber specified shall be deemed to be nominal <br /> load indicated in Table R301.6 or the ground snow load indi- dimensions unless specifically designated as actual <br /> cated in Table R301.2,whichever is greater. dimensions. <br /> TABLE R301.5 <br /> MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS(in pounds per square foot) <br /> USE UNIFORM LOAD CONCENTRATED LOAD <br /> (psf) (Ib) <br /> Uninhabitable attics without storageb 10 <br /> Uninhabitable attics with limited storageb,9 20 60 psf per <br /> Habitable attics and attics served with fixed stairs 30 WA-SBCC amend. <br /> Balconies(exterior)and decks' 40 <br /> Fire escapes 40 — <br /> Guards — 200h,' <br /> Guard in-fill componentsf — 50h <br /> Handraild 200h — <br /> Passenger vehicle garages' 50' 2'000h <br /> Areas other than sleeping areas 40 — <br /> Sleeping areas 30 — <br /> Stairs 40' 300' <br /> For SI: 1 inch=25.4 mm,1 pound per square foot=0.0479 kPa,1 square inch=645 mm2,1 pound=4.45 N. <br /> I a. Elevated garage floors shall be capable of supporting the uniformly distributed live load or a 2,000-pound concentrated load applied on an area of 4'/2 <br /> inches by 4'/2 inches,whichever produces the greater stresses. <br /> b.Uninhabitable attics without storage are those where the clear height between joists and rafters is not more than 42 inches,or where there are not two or <br /> more adjacent trusses with web configurations capable of accommodating an assumed rectangle 42 inches in height by 24 inches in width,or greater,within <br /> the plane of the trusses.This live load need not be assumed to act concurrently with any other live load requirements. <br /> c. Individual stair treads shall be capable of supporting the uniformly distributed live load or a 300-pound concentrated load applied on an area of 2 inches by <br /> 2 inches,whichever produces the greater stresses. <br /> d.A single concentrated load applied in any direction at any point along the top.For a guard not required to serve as a handrail,the load need not be applied to <br /> the top element of the guard in a direction parallel to such element. <br /> e. See Section R507.1 for decks attached to exterior walls. <br /> f. Guard in-fill components(all those except the handrail),balusters and panel fillers shall be designed to withstand a horizontally applied normal load of 50 <br /> pounds on an area equal to 1 square foot.This load need not be assumed to act concurrently with any other live load requirement. <br /> g.Uninhabitable attics with limited storage are those where the clear height between joists and rafters is 42 inches or greater,or where there are two or more <br /> adjacent trusses with web configurations capable of accommodating an assumed rectangle 42 inches in height by 24 inches in width,or greater,within the <br /> plane of the trusses. <br /> The live load need only be applied to those portions of the joists or truss bottom chords where all of the following conditions are met: <br /> 1.The attic area is accessed from an opening not less than 20 inches in width by 30 inches in length that is located where the clear height in the attic is not <br /> less than 30 inches. <br /> 2. The slopes of the joists or truss bottom chords are not greater than 2 units vertical in 12 units horizontal. <br /> 3.Required insulation depth is less than the joist or truss bottom chord member depth. <br /> The remaining portions of the joists or truss bottom chords shall be designed for a uniformly distributed concurrent live load of not less than 10 pounds <br /> per square foot. <br /> ' h. Glazing used in handrail assemblies and guards shall be designed with a load adjustment factor of 4.The load adjustment factor shall be applied to each of <br /> the concentrated loads applied to the top of the rail,and to the load on the in-fill components.These loads shall be determined independent of one another, <br /> and loads are assumed not to occur with any other live load. <br /> I i. Where the top of a guard system is not required to serve as a handrail,the single concentrated load shall be applied at any point along the top,in the vertical <br /> downward direction and in the horizontal direction away from the walking surface.Where the top of a guard is also serving as the handrail,a single concen- <br /> trated load shall be applied in any direction at any point along the top.Concentrated loads shall not be applied concurrently. <br /> 3-32 2018 INTERNATIONAL RESIDENTIAL CODE° <br />