ESG Design <br /> www.esg-design.com <br /> BeamChek v2023 licensed to:ESG Design Reg#2999-68483 <br /> \Sele <br /> sidence Patio Posts <br /> Prepared by: JM Date:4/19/24 <br /> 4x 4 Hem-Fir#2 Solid Wood Column <br /> NDS 2018, Using values for 2x and 4x solid sawn, Dimension Lumber. <br /> Incised <br /> Data Load 1100# Column Area /12.25i Kf 1.00 <br /> Actual Height 14.0 ft led1 Effective Ht c 0.80 <br /> Unbraced L1 9.0 ft le d2 Effective Ht KcE 0.30 <br /> braced L2 9.0 ft Ke Buckling Mode FcE 389 <br /> Fc �� (psi) E(psi x mil) <br /> Attributes and Values ontrolling d is 3.5 inches <br /> Refer nce Values 1300 1.3 <br /> le/d psi Area (in2) Ad' sted Values 359 1.2 <br /> Actual 1 90 12.25 Size Factor 1.15 <br /> Critical 359 3.07 Cd Duration 1.00 <br /> Status OK OK OK Ci Incised 0.80 0.95 <br /> Ratio 62% 25% 25% Cp Stability 0.30 <br /> Note:A wood plate under this column mu have an Fc v e, perpendicular to the grain, greater than 90 psi. <br />