Laserfiche WebLink
Deck Framing <br /> 4x4 Wood Post <br /> BeamChek v2023 licensed to:ESG Design Reg#2999-68483 <br /> Typical Wood Deck Framing Wood Framing <br /> 6'4X4 POST Prepared by: Date: 1/17/24 <br /> Selection 4x 4 Hem-Fir#2 Solid Wood Column <br /> Conditions NDS 2018, Using values for 2x and 4x solid sawn, Dimension Lumber. <br /> Incised <br /> Data Load 7000# Column Area 12.25 in Kf 1.00 <br /> Actual Height 6.0 ft le dl Effective Ht 72 in c 0.80 <br /> Unbraced L1 6.0 ft le d2 Effective Ht 72 in KcE 0.30 <br /> Unbraced L2 6.0 ft Ke Buckling Mode 1.0 FcE 876 <br /> Attributes and Values Controlling d is 3.5 inches Fc II (psi) E (psi x mil) <br /> Reference Values 1300 1.3 <br /> le/d psi Area (ink Adjusted Values 689 12 <br /> Actual 21 571 12.25 CIF Size Factor 1.15 <br /> Critical 50 689 10.16 Cd Duration 1.00 <br /> Status OK OK OK Ci Incised 0.80 0.95 <br /> Ratio 42% 83% 83% Cp Stability 0_58 <br /> Note:A wood plate under this column must have an Fc value, perpendicular to the grain, greater than 571 psi. <br />