My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6715 HIGHLAND DR 2025-09-30
>
Address Records
>
HIGHLAND DR
>
6715
>
6715 HIGHLAND DR 2025-09-30
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/30/2025 9:13:19 AM
Creation date
9/16/2025 11:08:17 AM
Metadata
Fields
Template:
Address Document
Street Name
HIGHLAND DR
Street Number
6715
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
55
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
....... ................... <br /> nSta anon pf�ons for Deck La. eras Loyd Connectors <br /> Allowable Loads <br /> m <br /> : <br /> 6-SD#9x1%2" 840 840 840 755 <br /> DTT1 Z 3/a" or 6-10dxi Y2' 910 6404 795 6404 <br /> SDWHS . 8-1Odx1W 910 850 910 850 <br /> DTT2Z(DTT2SS 13Zt6" %2" 8-SDS Ya"x1 Fe" 1825 1800 1825 1615 <br /> 1.Allowable loads have been increased 60%for short-term loading with no further increase allowed. <br /> 2.Dry values are applicable to installations into wood with a moisture content that does not exceed 19%. f <br /> 3.Wet values are applicable to installations into wood with a moisture content greater than 19%at time 41s��., <br /> of installation or in service.Values include an NDS wet service factor for the fasteners. <br /> 4.DTT1Z installations with allowable loads below 750 lbs.do not satisfy the 2015 IRC requirements for <br /> 10 <br /> deck-to-house lateral load connections. <br /> 5.DTT1Z installed with the Strong-Drive SOWH Timber-Hex HDG screw with a min.of 3"thread <br /> penetration achieves the lesser of the table load or 855 lbs.SDWH installed with 3"of thread <br /> penetration into dry lumber has an allowable withdrawal load(160)of 1380lbs.into SP,12251bs.into of <br /> and 1020lbs.into SPF/HF. <br /> 6.Load values are valid if the product is flush with the end of the framing member or installed away DTT1 Z <br /> from the end. <br /> 7.FASTENERS:SD#9xM(model SD9112)=0.131"dia.x 1%",10dx1'h=0.148"dia.x 1A'long. <br /> DTT2Z�P <br /> Conditions Not Shown in the IRC <br /> The IRC details describe particular methods that are appoved and do not represent all common framing conditions.When <br /> these are encountered,alternate methods of construction may need to be approved by the building official to ensure they <br /> satisfy the intent of the code and are at least equivalent to the prescribed method.Several alternate construction methods <br /> are shown here. <br /> DTT1Z DTT1Z—750-Pound Assembly a <br /> Condition 1—Holdown Cannot Be Installed Flush o <br /> with Wall Sheathing ce <br /> Unlike some holdowns,the DTT1Z seat is not <br /> �; required to bear on sheathing or framing and can be <br /> 3 Min. c installed away from the wall to account for non- e <br /> f structural siding,joist hanger interference or other <br /> a conditions.Longer screw anchors may be required o <br /> 3"Min. to ensure a minimum of 3"thread penetration by a <br /> fully threaded lag screw or Strong-Drive°SDWH <br /> Timber-Hex HDG screw into the wall framing. y <br /> DTT1Z Condition 2—Top of Wall Plate Does Not Align N <br /> Do not over-drive with Bottom of Deck Joist <br /> anchoring screw <br /> The 2015 IRC detail shows a holdown installed on <br /> Predrill 3/16"dia.hole for fully threaded the bottom of the joist.However,the DTT1 Z was <br /> lag screw.Predrilling not required with tested and developed using 1Ili"fasteners into <br /> Stron g-Drives SDWH Timber-Hex HDG Screw. either the narrow edge or wide face of a 2x member, <br /> (Siding not shown for clarity) allowing the DTT1Z to be installed at any location <br /> along the depth of the joist. <br /> Figure 4 <br /> 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.