Laserfiche WebLink
........... <br /> FACE MOUNT GUARDF05T CONNECTION CHECK <br /> ALUMINUM GUARD R05T <br /> 200#POINT LOAD (TABLE IRG 310.5) <br /> m <br /> MR= 200#x(36" + 3")= 7800 LB -IN <br /> DECK J015T BEYOND <br /> zr__ <br /> MIN 2X8 RIM J015T (2) 2x8 BLOCKING <br /> LAG SCREW ATTACHMENT <br /> T,,= (Tension in each screw) = 7500#/4"(Distance between screws)12 screws = q75 Wscrew <br /> Withdrawal Capacity of 3/&"X 5" Lag Screw=2431b/in (HF#2 56 = .43) <br /> Allowable Withdrawal = 243"x 4.5"= 10g3#Iscrew <br /> 10`13# > q75# OK------> Use (4)3/8"dia X 5" Lag Screws <br /> W#14 5CREW5 EACH <br /> END OF BLOCKIN6- <br /> J015T TO BLOCKING <br /> MIN 2x8 J015T <br /> RIM JOIST <br /> SIDE CONNECTION SHEAR <br /> T5= (Tension in each screw)= q75#I5crew x 2 screws = 1 q50#shear <br /> Y5(#14 5CREW HF 56 = 0.45)= 1 q5#I5crew <br /> N= 1 g501bs/ 1 q5#/screw= 10 screws-------> Use (5)#14 screws each end of blocking (16 total screws) <br />