. ...... .. <br /> CJy I.JCSI/,.11 <br /> www.esg-design.com <br /> Beam Chek v2023 licensed to:ES Design Reg#2999-88483 <br /> Novak Residence Patio Roof <br /> New Beam 2 Prepared by: SM Date:4/19/24 <br /> Selection 4x 6 HF#2 Lu = 0.0 Ft Lu @OH= 0.0 Ft <br /> Conditions NDS 2018, Overhang <br /> Min Bearing Area R1= 1.4 in' R2= 1.8 in (1.5)DL Defl= 0.09 in. <br /> Data Beam Span 8.0 ft Reaction 1 LL 394# Reaction 2 LL 506# <br /> Beam Wt per ft 4.68 # Reaction 1 TL 570# Reaction 2 TL 732# <br /> Bm Wt Included 42# Maximum V 588# Overhang Length I.0 ft <br /> Max Moment 1120 W Max V(Reduced) 521 # Total Beam Length 9.0 ft <br /> TL Max Defl L/240 TL Actual Deft L/410 OH TL Actual Deft L/250 <br /> LL Max Deft L/360 LL Actual Deft L/684 OH LL Actual Deft L/417 <br /> Attributes Section in' Shear in2 TL Deft in LL Deft OH TL Deft OH LL Deft <br /> Actual 17.65 1925 0.23 0.14 -0.10 -0.06 <br /> Critical 12.17 5.21 0.40 0.27 0.10 0.07 <br /> Status OK OK OK OK OK OK <br /> Ratio 69% 27% 59% 53% 96% 86% <br /> Fb psi Fv psi - E (psi x mil) Fc l (psi) <br /> Values Reference Values 850 150 1.3 405 <br /> Adjusted Values 1105 150 1.3 405 <br /> Adjustments CF Size Factor 1.300 <br /> Cd Duration 1-00 1.00 <br /> Cr Repetitive 1.00 <br /> Ch Shear Stress N/A <br /> Cm Wet Use 1.00 1.00 1-00 1_.00 <br /> Cl Stability 1.0000 Rb =0.00 Le=0.00 Ft <br /> Cl Stability @ OH 1.0000 Rb =0.00 Le = 0.00 Ft <br /> Loads Uniform LL: 100 Uniform TL: 140 =A (Uniform Ld on Sacks an <br /> Par Unif LL Par Unif TL Start End <br /> 100 K= 140 (OH) 0 1.0 <br /> Uniform Load A <br /> R1 =570 R2= 732 <br /> BACKSPAN =8 FT OH = 1 FT <br /> Uniform and partial uniform loads are lbs per lineal ft. Overhanging load distances are from R2. <br />