Laserfiche WebLink
SLIGII IC GLASS CC%OR <br /> SELF �Nt-IVE PER I_AN <br /> MEMBk \E°I / SLIDING GLA5E COOK EXTEND MIN.6'UP JAMB <br /> FLASHING ---- % NAIL <br /> NAIL CriIBCE GALJ FLASHI NRVASTRAL TO EXTEND <br /> 2' F //�2'PAST THE INTERIOR HEADER/ <br /> FLAS+II ----- /i S 4'tTOF :L +G STI•C OF THE DOOR \\HEADER \ <br /> i - - <br /> FLOOR JOI l A / - EGGED T ktl A / <br /> PER f 1, / i .... <br /> T - - PER PLAN WAIE•r_i: ROUGH ROUGH <br /> �y 'l BARhIFF, OPENING OPENING <br /> JOL.. . L.-ti / JAMB\ JAMB\ <br /> D PI- / SILL \ / SILL \i. �� --HANGER PER°LAN JOIIn I.,, 2N GCE IU <br /> / N5 <br /> N NO EI„fE - PENETRATION <br /> RIM JOIST - I .--- -PT L-DOER PER 7'LA�J CON]-,,- <br /> BUILDING /57 b <br /> .BIER-­4 1 -SHEATHING PER FLAN - PIfCF 1Y• SILL S <br /> INSTA- EC BEHIND SIDI c, FLASHING <br /> LEDGER AIJC PAN PL3 BUILDING PAPER TO EXTEND <br /> FLAOVER J E - l'w/LEDGER <br /> PAPER BEHIND w II - -�- <br /> ,---SIDING PER PLAN <br /> OVER 111.L WR-P +LEDGER INSTALLED BEFORE S I�!5 MIN.12'BEYOND ALL EDGE5 STEP I STEP 2 <br /> EXTEND 12"BEYOND ` - OF THE PENETRATION .ATTAC SILL STRIP OF 9'WIDE MOISTOP(OR EQ.)FLASHING MATERIAL •ATTACH JAMB STRIPS OF 9'WIDE M015TOP(OR EQ). y , <br /> EXPOSED ON ALL,S,DE'c - OPENING WITH THE TOP EDGE EVEN WITH THE TOP OF THE ROUGH SILL. FLASHING MATERIAL WITH INSIDE EDGE EVEN WITH THE JAMB Lu <br /> _ _ ATTACH FEXTEND LIS ASHING N6 MATERP AT IAL WITH BEYOND THE EDGE OF THE ROUGH OF THE ROUGH OPENING. / <br /> DECK LEDGER DETAIL S it\u E - FLASHING �� EXTERIOR DOOR FLASHING PROTECTION — OPENING. START JAMB STRIPS F BELOW SILL STRIP AND EXTEND 6° <br /> 1/I•I',!'?I 1111 G� I/ II Al PENETRATION H CORROSION-RESISTANT STAPLES, ABOVE LOWER EDGE Of HEADER. <br /> N.T.S. SCaIL d f S. YVIJ SCALE:N.T.S. VV I'i SCALE:N.T.S. 1 J <br /> co+rER mIn+uxv+Is a }- ,?� 1 f <br /> FGart oam SEALANTCONT <br /> OF ' , f ` <br /> sIx a s.IOER HEAD / V-1 v <br /> UNDER NAIL FIN \ <br /> EQ. R FL45HING y 2" <br /> YI SGD PER <br /> PLAN / <br /> p� � CUT AWAY <br /> LINE cf L t - �. _.a LPA <br /> DOW _--EXCE55._. - -__ WINDOWfNERVESTRAL ------ ------ 3i NFARTWDW CEDAR TRIM ILAR P OPENING 'a1A 1E OR BLGG PAPER FRAME ORTO HOSE BIB BEHIND 1 Eo,ALL SIDES,u2rJ5EAL SIMILAR� E0 # � E0. NING OPENING <br /> 3-6 TO 5'3' ANDING P. #NOTE: SEAL ALL =__ <br /> SIDING POUR AGAINST BUILDING_-'---- <br /> L L of NERVAs RAL EXPOSED FASTENERS <br /> PRONTO FRONT FORCN PA <br /> no —BUILDING PAPER <br /> BEND _ ELECTRIC,- 3'-6'LANDING TYP. `SHEATHING PER PLAN PAPER TYP. <br /> _ METER M'IANd P BACK PATIds sac"Ana.s"cu�o ururs BLDG PAPER LINE OF BUILDING PAPER TYP. <br /> P01�D'"Tue Di0.s''LL" INSULATION <br /> a THE nxm sloE of nuNAIL FLANGE UNDER SILL STRIP <br /> sc.v.wlTrvwsn B>ssns PER PLAN [------APPROVED — - <br /> �® J PRONTO BE L .19X10 BASHING STEP 3. ST&4 <br /> FRON- 214 HFARTHKOp CEDAR TRIM <br /> _INSTALL H 1•: DOOR (O.Iq x IOC ROLL) •APPLY A 3/B'CONTINUN5 BEAD OF CAULK TO THE BACK OF THE FRAME •APPLY THE NEXT COURSE OF BUILDING PAPER BU`ING TO THE <br /> CORNER �.OF HL LSE TNRE5110LD LANDING PER PLAN.PaUR ( <br /> OF HLUSE AGAINST NERVES- as uEARTwooD cEoaR SIDING PER PLAN 1-)/2'GAP NAILING FLANGE AT ALL 5IDES OF THE WINDOW FRAME OPENING OVER THE JAMB FLASHING MATERIAL. <br /> -- -.__-._________ TRIM INTERSECT <br /> PUSHING P <br /> AT G.aRAGE HOSE 507<FB., � � - �.+ BTWN ROOF AND SIDING .PLACE AND SECURE FRAME INTO ROUGH OPENING WITH FLANGES OVER THE •APPLY SUCCEEDING LAYERS OF BUILDING PAPER IN SHINGLE W — <br /> NERVESTRAL HOUSE INTERSECTION, <br /> Imo'8108 TARTEI: ,A.I I: MIN.N6,T Ptn:y I_ _ WHERE OCCURS INSTALLED JAMB AND SILL t JAMB MOISTOP(OR CIFI FLASHING MATERIAL. BOARD FASHION UP THE WALL, LAPPING COURSES A MINIMUM OF <br /> INSTALL (MIN. 3',rrP.i _ 1 ROOF SHINGLES •NAIL WINDOWS PER WINDOW MANUFACTURER'S SPECIFICATIONS I/2 PAPER v11DTH, <br /> GROUNOn;, rLaSHP,i, =,, -- Nw SILL 'SITECONDITIONS BD Br i LINE of HERVESTRAL •STARTING FROM THE BASE OF THE WALL,APPLY BUILDING PAPER UNDER <br /> GUTTER '.K �I SLAB aN GRADE WA FELT TO EXTEND UP •ABOVE TN F51�LL AND BET ANY IXHE L BUILDING PAPER OPENING, <br /> MAY EXTEND <br /> _ROD 12 °RGPI WALL I2'MIN. THE SILL STRIP AND CUT <br /> PRONTO BEN' wNc.WALL BETWEEN THE JAMBS OF THE OPENING. <br /> RT�FL DH o/F-ASH NG -1 ADD FORT LASHING P BO]-H 5IDES OF WINDOW p u <br /> .I° ?LAN- ROOF TRUSS - -. - " •APPLY SLOPED 28 GA 2 BACK, PREFINI5HED METAL FLASHING TO OPENING. <br /> D MOISTOP TERN - AND"x'"T PO °BALL ROOF SHEATHING PER PLAN •APPLY 6'FORTIFLA5H OVER TOP HEAD FLANGE OF WINDOW.EXTEND PAST <br /> :.:RTifLA,IJ OIJTO P�.WEL z, FLASHING <br /> EXT. LANDING DETAIL @ ROOF TRU55JAMB <br /> 12 T t ORNERS FASCIA1 F ` @ SAVE W12 SLIDING GLASS DOOR, TYP WII ROOF TO WALL FLASHING W1� STANDARD FLASHING MATERIAL APPLICATION AT OPENINGS C) <br /> a2 TRIM v PERIMETEK-- 1 I Ii _. � 1 <br /> GFENING FOR E.EC.-- `` - \ ..1.,I_ SCALE.N.T.S. SCALE N.T.S. SCALE:N.T.S. <br /> "IETER BOX F REPLn .. <br /> DIRECT VENT RANGE VENT, 1 - -- <br /> SEALANT---�\ 7/16'PLYWD.SHEATHING <br /> DRYER ANT, ETC. WINDOW FRAME <br /> +SEE DETAIL 110 FOR 1:OIETOP INSTALS I:JS 1._ a: 3/8'BEAD CAULK INSULATION <br /> SILL ASSEMBLY <br /> PER SPEC-- SEALANT (WHERE OCCURS)- -b'FORTIFLASH 0/FLASHING <br /> ELECTRIC METER $ HOSE E1-. GYP.BD. WD.FRAME WALL -SIDING PER PLAN <br /> TRIM PER ELEVATION <br /> LOCATION GAS METES PER PLAN— ---- -- — <br /> C (WHERE APPLICABLE) INSULATION BUILDING PAPER <br /> W"J l -- TRIMMER (WHERE OCCURS) R-10 INSULATION--- MOISTOP(SEE DETAIL WHO <br /> i SLA,.E.N.T.S. <br /> GYP.BD. MOISTOP(SEE DETAIL KING STUD BEHIND HDR,TYP P FOR INSTALL) <br /> MIN I/4° <br /> WIO FOR INSTALL) NO,FRAME WALL ALL HDR's _ <br /> SEALANT PER GAP BTWN SIDING PLAN _AND FLASHING COPYR49 NOTICE:THIS <br /> MIN.IB" EXT WALL PER FORTIFLASH ON ALL GYP,BD. <br /> MOISTOP(SEE \, PUN IS OFNED BY PACIFIC <br /> DETSIDES OF WINDOW W N AIL W10 <br /> COW FRAME _ 7/16'PLYWD.SHEATHING HEADER PER PLAN --- �'FLASHING TURN DOWN j RIDGE ud7Es.USE of THIS <br /> PLAN ___ \ PLAN Is PRcuIBrEo BY <br /> uw <br /> FOR INSTALL / LICENSE FEE To PACING <br /> SIDING PER PLAN ) I WITHOUT PAYMENTIDT a <br /> I/4"AT EACH END�� <br /> INSULATION IM PER ELEVATION I RIDGE HOMES <br /> APR TYP. (WHERE OCCURS) BLDG.PAPER BLDG.PAPER (5EE ELEV.FOR <br /> 10,-e -10 H05E BIB SEALANT (WHERE APPLICABLE) <br /> _ I °ER PLAN TRIM P R ELEVATION SIDING PER PLAN WINDOW HT) SEALANT � PLAN SUMMARY <br /> 11 7/16"PLYWD.SHEATHING <br /> / EDGE TO 6"TO C.L. 9ED TRIM ' WHERE APPLICABLE) FORTIFLASH ON ALL SEALANT —� T-t7NINDONF PRONTO BEND --- ( SIDES OF WINDOW FRAME <br /> 3 6" °° 1,; �RNER WINDOW SILL @WOOD FRAME WALL WINDOW JAMB DETAIL WINDOW HEAD DETAIL <br /> EDGE TO I�,"� - W/ <br /> EDGE _ EDGE L 7 2a..L (�V� SO " - P�J SCALE:N.T.S. XV/ SCALES N.T.S. 1O SCALE:N.T.S. S14 <br /> 95 <br /> RON <br /> OR ER <br /> f. a _ STUDS P IDS (NO POSTS/ QQ�C{so <br /> OF�OUEt LAP SIDING,U.G R (HOLE)I-IM' POINT LOADS ABOVE VENTS)- cw.rt uuwGr., <br /> AT GARAGE OFF ADJOINING ROOF) ' i�' <br /> 'LAG SCREW ' SIDING PER PLAN 405 <br /> oB Y ATTACHGASED METAL FLASHING EQ. <br /> METER 1 •,;1.._ .STUDS.LAG (MAY BE STEPPED) ' q - EO—+�" BOTTOM SILL PLATE NFAT°0"�' <br /> _ 20LhJ rl� 9 PENETRATE BUILDING PAPER ON 3/4'TOG 5UBFLOOR GAS <br /> - SHEATHING(SIDING CUT I ii FLASHING - JWA <br /> I MIN.,TYP.P IJ <br /> AswGxGuw rwe mnorN.ras I <br /> JD 2/3 HT OF AWAY FOR CLARITY) 1 .7_I/2'x15-1/2'CEDAR RIM <br /> FORTIFLASH o/F-5HING TACN w/I i's' - -- , <br /> ANO MOI5TOP.TURN --� 1 It'.�1G >.STRAP MIN METAL RAIN DIVERTER(THE i VENTS w/GALV SCREEN- <br /> f-ORTIFLASH I''ONTO PANEL '�� <br /> PURPOSE IS TO SHED THE PROVIDE LOUVERED VENTS / BTL ENGINEERING <br /> -:.LL 51GE5 c CORNERS. ,ii N NW7 WATER OFF THE ROOF AND - P FRONT ELEVATIONS <br /> KEEP IT AWAY FROM THE ROOF SHINGLES RIM PER PLAN SEE REVISION LOG <br /> _.2 TRIM i PERIMETER VERTICAL WALL BENEATH), PER SPEC. <br /> LL <br /> OPENING FOR ELEC. - - f'�IJ Il'OF HWT FASCIA PER PLAN w/ '� CONCRETE FOUNDATION <br /> FOUNDATION SCALE: Y,' I'-0" <br /> _ 301t ROOF FELT <br /> METER BOX, FIREPLACE _\ GUTTERrs <br /> A+DO NOT INSTALL VENT 5 CLOSER THAN 3'TO GAS METER" WATER <br /> DIRECT VENT, RANGE VENT, I".ET2. �. - 7/16'O58 ROOF () <br /> DRYER VENT,ETC SHEATHING ++BUILDING PAPER SHOULD BE INSTALLED OVER FLA514I14G+> INTRUSION <br /> NOTE:PER WSEC R402.2.7:WHEN FOUNDATION VENTS ARE NOT PLACED 50 THAT THE TOP DETAILS <br /> +SEE DE'AIL n10 FOR MOiSTOP INSTALL uJST OF THE VENT 15 BELOW THE LOWER SURFACE OF THE FLOOR INSULATION,A PERMANENTLY <br /> *NOTE. SEAL ALL ATTACHED BAFFLE SHALL BE INSTALLED AT AN ANGLE OF 30'FROM HORIZONTAL,TO <br /> ELECTRIC $ GAS METER; F!, -L - USE 3 STRAPS ON 75 GALLON AND GREATER SIZES EXPOSED FASTENERS DIVERT AIR FLOW BELOW THE LONER SURFACE OF THE FLOOR INSULATION, <br /> W5 BIB CLEARANCES LOCal IDr';S WATER HEATER (HAT) STRAPS DETAIL @ ROOF/WALL INTERSECTION �1v�I / FOUNDATION VENT <br /> SCALE:N.T.5, SCALE:N.T.S. SCALE:N.T.5. �V� SCALE:N.T.5. <br />