SL:DiNz:GU155 LriF:
<br /> SELF ACHESIVE ... -PER PL J
<br /> MEMBRANE PAN SOC JG r LA55 Cd9R EXTEND MIN.b'UP JAMB
<br /> FLASHING NAIL L NGE
<br /> NERVASTRAL TO EXTEND I -
<br /> NAIL ON FLEXIBLE —GALV FL E ING /
<br /> FLASHING 2"MIN f,?I5 TOP 0r 2"PAST THE INTERIOR
<br /> FLOOR JOIST �\ \ /�LEDGER TO LAG aCREIN SI I. OF THE DOOR HEADER HEADER
<br /> PER PLAN !i�� 5/4x tL R CECKIP'G 'I ROUGH ROUGH
<br /> ' PER P' _( WA1En OPENING OPENING
<br /> -- - / BARRIF
<br /> 2,PT T'c; rl_y _. JAMB\ - JAMB\
<br /> - Hi'NuLK rE':FLAN JOINT 2N0'FIECE f / SILL \ '�I / SILL \
<br /> IN51; -F.
<br /> IN rl0 EL!f / PENETRATION
<br /> RIM JOIST .— IS i 6'
<br /> PT LLD LR P�P.�,N CONTr: T PIECE j� I
<br /> BUILDING PAPER—�I I. ASILL -
<br /> INSTALLED BEHIND __5HEATHiNG PER IAI SIDud: 12' FLASHING
<br /> LEDGER AND PAN —-SIDING PER PLAN PLAIt BUILDING PAPER TO EXTEND
<br /> FLASHING.LAP F LEDGER INSTALLED BL a C N:F MIN.12'BEYOND ALL EWES STEP I STEP 2
<br /> OVER HOUSE WRAP EXTEND 12'BEYOND OF THE PENETRATION •ATTACH SILL STRIP OF 9 WIDE MOISTOP OR EQ. FLASHING MATERIAL •ATTACH JAMB STRIPS OF 9"WIDE MOISTOP OR EQ
<br /> EX Lu
<br /> BUILDING PAPER BEHI .o/J° OPENING ( ) ( )
<br /> EXPOSED ON ALL H SDtS WITH THE TOP EWE EVEN WITH THE TOP OF THE ROUGH SILL. FLASHING MATER�.AL WITH INSIDE EDGE EVEN WITH THE JAMB ?
<br /> •EXTEND T1415 STRIP AT LEAST 12'BEYOND THE EWE OF THE ROUGH OF THE ROUGH OPENING. = L
<br /> / JI /�V� FLASHING OPENING. •START JAMB STRIPS 2'BELOW SILL STRIP AND EXTEND b" —
<br /> DECK LEDGER DETAIL EXTERIOR DOOR FLASHING PENETRATION PROTECTION ATTACH FLASHING MATERIAL WITH CORROSION-RESISTANT STAPLES. ABOVE LOWER EWE OF HEADER �
<br /> W22 - W16 -
<br /> C-� N.T.S. SCALC N f WI5 SCALE:N.T.S. WI4 SCALE:N.T.S. n/
<br /> w
<br /> Fa�+r max" CONT,BERG OF F \
<br /> 9DE 6 Ylak HEAD —SEALANT ■ �l
<br /> ), jl FLASHING UNDER NAIL FIN
<br /> E0. FA 2" 2"
<br /> �1 SGD PER PLAN
<br /> i J (OPERPBLE F� CUT AWAY ^/
<br /> / = - J J WINDOW EXCESS WINDOh L L
<br /> FRAME
<br /> 53 A6"TOOHOSE BIB 1 BEHIND
<br /> EQ.---- - --- --� W.ALL SIHN�TIPLIV5EAL TE. SEAL ALL III OPENINGLINE OFR/J 6LDG PAPER GILDING FQ IL OR if
<br /> NERVFSTRAL 2,6+RARTWLOD CEDAR TRIM, I �l
<br /> ___ I SIMILAR P OPENING SIMILAR
<br /> PENING
<br /> — BOMaIaF aN0
<br /> EXPOSED FASTENERS
<br /> C.L.OF NERVASTRAL BUILDING PAPER
<br /> PRONTO FRONT PORLI+ PATIO - PAPER
<br /> BEND_ _ELECTRICAL 3'-b"LANDING TYP SHEATHING PER PLAN TYP TYP.
<br /> e"nc rATIa•sau�o Au..n LINE OF BUILDING PAPER
<br /> METER MAIN Q. P BACK PATIO's INSULATION BLDG PAPER i, NAIL FLANGE UNDER SILL STRIP
<br /> a ruF FIVFo sme o<ruc
<br /> j 9 sw.w+cveveR eossisE PER PLAN APPROVED FLASHING -
<br /> PRONTO d N,-. 2.6 HEARTWOOD CEDAR TRIM STEP 3 STEP 4
<br /> f ONT -- INSTALLED 01, DOOR -'L- (0.19 x 10'ROLL) •""-� O
<br /> CORN.R �- �OF HaSe THREsuDLD DING PER Plit+.Pam ' •APPLY A 3/b"CONTINUOUS BEAD OF CAULK TO THE BACK OF THE FRAME •APPLY THE NEXT COURSE OF BUILDING PAPER(BUTTING TO THE
<br /> _ AGAINST NERVE5TRAL 211 NEARTWCOD CEDAR SIDING PER PLAN -I/2"GAP NAILING FLANGE A7 ALL SIDES OF THE WINDOW FRAME OPENING OVER THE JAMB FLASHING MATERIAL.
<br /> Or HOUSE '« BTWN ROOF AND SIDING •PLACE AND SECURE FRAME INTO ROUGH OPENING WITH FLANGES OVER THE -APPLY SUCCEEDING LAYERS OF BUILDING PAPER IN SHINGLE ��
<br /> AT GARAGE - HOSE 30R FELT __ _ _________I Twn"✓PusHlru e
<br /> NERVESTRAL HOUSE INTERSECTION, I1
<br /> BIBS _lpyp Opt pLµ I_ _ WERE accuRS INSTALLED JAMB AND SILL f JAMB MOISTOP(OR EQ.)FLASHING MATERIAL. BOARD FA5HION UP THE WALL, LAPPING COURSES A MINIMUM OF ll.�
<br /> StARTEk t (nw,3,xy,TrP) 5$ROOF SHINGLES •NAIL WINDGWS PER WINDOW MANUFACTURER'S SPECIFICATIONS I/2 PAPER WIDTH. -�
<br /> INSTALL x a:STEPSYR)eY ' uNE of NERVESTRAL •STARTING FROM THE BASE OF THE WALL,APPLY BUILDING PAPER UNDER _ Q
<br /> GROUNDING FLASHING- � nuD sLL SITE CONDITIONS 30ri FELT TO EXTEND UP THE SILL STRIP AND CUT ANY EXCE55 BUILDING PAPER THAT MAY EXTEND
<br /> FORTIFLASH u w ROD 12 BENDFRCIl WALL 12'MIN.
<br /> PRONTO BENC corn WALL sue ON GRADE ABOVE THE SILL AND BETWEEN THE JAMBS OF THE OPENING.
<br /> •ADD FORTIFLASH STICK FLASHING P BOTH 51DE5 OF WINDOW
<br /> /FLASHING 0f PUTTER'rE 5tf'' ROOF TRU55 I' E o'°°� -, •APPLY SLOPED 2B GA..2'BACK,PREFIN15HED METAL FLASHING TO OPENING. 1--L-1
<br /> _ - r PLAN-- - -- µx r•�rt Faux a:Tu� ROOF SHEATHING PER PLAN •APPLY 0 FORTIFLASH OVER TOP HEAD FLANGE OF WINDOW EXTEND PAST
<br /> AND
<br /> I^OISTOF TURN— - _
<br /> I OKT'FLASH OIJTO PAN L; FASCIA PEI,h :J EXT. LANDING DETAIL @ ROOF TRUSS
<br /> JAMB FLASHING 2",
<br /> ALI SIDES r CORNERS.
<br /> 2x2 TRIM�FERIME, R TrP H"" FL SNIPi @ EAVE SLIDING GLASS DOOR, TYP ROOF TO WALL FLASHING STANDARD FLASHING MATERIAL APPLICATION AT OPENINGS
<br /> OPENING FOR ELEC- --00 II 3L Ln; �W13 w\LE N.T.S. W12 SCALE:N.T.S. WII SCALE:N.T.S. WIO SCALE:N.T.S.
<br /> METER BOX,FIREPLACE � _ PAPER N G
<br /> IKECT
<br /> O VENT,RANGE VENT AIL., METER MAIr, SEALANT
<br /> DRYER VENT, ETC, WINDOW FRAME 7/16"PLYWD.544EATHING
<br /> 3/3'BEAD CAULK INSULATION ._�
<br /> +SEE ULTAIL WIO FOR MOISTOP INSTAL INSTf+L:.?m:ii; SILL ASSEMBLY (WHERE OCCURS) b"FORTIFLASH 0/FLASHING E \
<br /> M k C _ PER SPEC �.�-�-SEALANT `J
<br /> ELECTRIC METER $ HOSE CIE- TRIM PER ELEVATIOJ GYP.BD. NJ).FRAME WALL SIDING PER PLAN
<br /> LI�CATION ND GAS ME kp I (WHERE APPLICABLE) INSULATION PER PLAN BUILDING PAPER
<br /> CWC R ._- _-.. (WHERE OCCURS)
<br /> J TRIMMER R-10 INSULA710N— MOISTOP(SEE DETAIL WIIO
<br /> SCALE IT 5. MOISTOP(SEE DETAIL BEHIND HDR,TYP P FOR INSTALL)
<br /> GYP.BD. KING STUD MIN.I/4"GAP BTWN SIDING
<br /> WIO FOR INSTALL) WD.FRAME WALL ALL HDR's _
<br /> SEALANT PER PLAN % AND FLASHING COI MIGHT NOTICE TH15
<br /> MIN.IW EXT WALL PER FORTIFLA5H ON ALL Grp.BD. - P4u+11 OWED 11 PACIFIC
<br /> PLAN M015TOP(SEE
<br /> j SIDES OF WINDOW FLASHING TURN DOWN j PRIZU 14 HCT7E5.BITE a THIS
<br /> DETAIL WIO HEADER PER PLAN -
<br /> ' 7/Ib"PLYWD.SHEATHING I/H'AT EACH END—� ' \ PDu+Is PROHIBITED er LAW
<br /> SIDING PER PLAN FOR INSTALL) LICENSE FEE
<br /> TO P CI
<br /> INSULATION WINDOW FRAME I RI ENOTE5
<br /> TRIM PER ELEVATION \ LICENSE FEE TO PACIFIC
<br /> i I ( ,PER TYP. (WHERE OCCURS) BLW.PAPER SEALANT BLDG.PAPER (SEE ELF, LEV.FOR (WHERE APPLICABLE)
<br /> 10'-6"TO HOSE BIB sR PLAN SIDING PER PLAN
<br /> 7/16'PLYWD.SHEATHING TRIM PER ELEVATION WINDOW HT SEALANT / F.-AN SUMMARY
<br /> 8-0 TO C.L. _D TRIM ... FORTIFLASH ON ALL SE41AN7 -'-.�
<br /> (WHERE APPLICABLE) -WINDOW FRAME
<br /> _ _OF...FRONT BEND,._ —�;.t .. SIDES OF WINDOW PLS4
<br /> "� Illl )RNER WINDOW SILL @WOOD FRAME WALL WINDOW JAMB DETAIL U WINDOW HEAD DETAIL �NY�xiM
<br /> 3 b'' 3'-0' "
<br /> EDGE TO EWE TO I - LIQ L+7 Lt/
<br /> "I - - VVV YV l YVfO 89i
<br /> EWE EDGE e.TF.IGr SCALE IJ I b SCALE:N.T.S. SCALE:N.T.S. SCALE:N.T.S. u�maxin
<br /> t ER MWI,
<br /> 12`rl
<br /> STUDS P Ib"a(NO POSTS/ r2102
<br /> F�N1
<br /> CRIER -i_U E LAP SIDING,U.NO.(HOLD I-I/2" i
<br /> POINT LAADS ABOVE VENTS
<br /> OF OJ E OFF ADJOINING ROOF) %"i 430
<br /> AT GAR/.F - : LAG SCREW SIDING PER PLAN _
<br /> METAL FLASHING '
<br /> Y ATTACHED EQ. BOTTOM SILL PLATE
<br /> -GAS I,y ;,,,_L (MAY BE STEPPED) / ` ELECTRIC
<br /> ' STUDS.LAG
<br /> ' METER �':. / ,:aomurw+.vls<omw*a
<br /> PENETRATE BUILDING PAPER ON / i~ VENTSN�I GALV SCREEN
<br /> '11N.,TYP.P SHEATHING(SIDING GUT I JI
<br /> rc01 .:END J 2/3 HT OF AWAY FOR CLARITY) 7 /2 15
<br /> FORTIFLASH o/FLASHING ACH w/196 a �I L ENGINEERING
<br /> AND MOISTOP TURN ---- !a- .STRAP MIN METAL RAIN DIVERTER(THE �•
<br /> FORTIFLASH I"ONTO PANEL, PURPOSE 15 TO 54ED THE \ III FRONTEOVIDE LEVATIONS ED ENTS 'w
<br /> ALL SIDES t CORNERS. T OF`w WATER OFF THE ROOF AND �. ROOF SHINGLES -Rr.�EVIQ ION LOG
<br /> -FLA II L KEEP IT AWAY FROM THE E PER SPEC, \ RIM PER PLAN /
<br /> &2 TRIM n PERIMETER I I_YP VERTICAL WALL BENEATH). �, \2-PS MUD SILL 51r ALOE:"}'u = II_O"
<br /> OPENING FOR ELEC.-- -bJ J r G T OF HWT FASCIA PER PLAN w/ 30K ROOF FELT CONCRETE FOUNDATION
<br /> _ PA �L.uI:C GUTTER �'•,� 7/I6'O50 ROOF "-DO NOT INSTALL VENT(5)CLOSER THAN 3'TO GAS METER-,METER FAX,FIREPLACE _ / J WATER
<br /> GRE_T VENT,RANGE VENT, METcr,.9r..Pi INTRUSION
<br /> DRYER VENT, ETC. �✓/ SHEATHING '-BUILDING PAPER SHOULD BE INSTALLED OVER FLASHINGs,
<br /> NOTE.PER WSEC R402.2.7:WHEN FOUNDATION VENTS ARE NOT PLACED 50 THAT THE T DETAILS
<br /> OF
<br /> +SEE DETAI_WIO FOR MOISTOP INSTALL INdT-1 L OF THE VENT 15 BELOW THE LOWER SURFACE OF THE FLOOR INSULATION,A PERMANENTLY
<br /> / p C ,I MOTE: SEAL ALL ATTACHED BAFFLE SHALL BE INSTALLED AT AN ANGLE OF 30'FROM HORIZONTAL,TO
<br /> ELECTRIC It GAS METER r t = USE 3 STRAPS ON 75 GALLON AND GREATER SIZES EXPOSED FASTENERS DIVERT AIR'LOW BELOW THE LOWER SURFACE OF THE FLOOR INSULATION,
<br /> G}BIB CLEARANCES $ LOCAT10,, WATER NEATER (NWT) STRAPS DETAIL @ ROOF/WALL INTERSECTION FOUNDATION VENT 1
<br /> - ----
<br /> SCALE:N.T.5. SCALE:N.T.S. SCALE:N.T.S. SCALE:N.T.S.
<br />
|