A F <br /> BUILDING CODE GENERAL <br /> 2018 INTERNATIONAL BUILDING CODE 1. ALL MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE <br /> CONTRACT DRAWINGS. SHEARWALL SCHEDULE (CDX) <br /> FLOOR LOAD 2. DURING THE CONSTRUCTION PERIOD THE CONTRACTOR SHALL C <br /> DEAD LOAD : 12 psf BE RESPONSIBLE FOR THE SAFETY OF THE BUILDING. THE MARK SHEATHING EDGE NAILING FIELD NAILING SILL PLATE & BOTTOM/TOP PLATE 5 <br /> LIVE LOAD: 40 psf CONTRACTOR SHALL PROVIDE ADEQUATE SHORING, BRACING, AND D K " 0 A.S. 0 4 CONN. <br /> GUYS IN ACCORDANCE WITH ALL NATIONAL, STATE, AND LOCAL J �6" CDX ONE 3fi" 0 A . ® ILL LTP4 x BOTTOM <br /> OM ��I x E tiQ <br /> ROOF LOAD SAFETY ORDINANCES. ANY DEVIATION MUST BE APPROVED IN FACE 8d ® 6" 0/C 8d ® 12" 0/C 0/C W/ 2x SILL W/ 2x BOTTOM <br /> DEAD LOAD: 15 psf WRITING PRIOR TO ERECTION. B PLATE PLATE <br /> FLAT ROOF SNOW LOAD: 25 psf " CDX ONE 96" A.B. ® 36" LTP4 ® 14" O/C <br /> SNOW EXPOSURE FACTOR (Ce): 1.1 3. ALL ERECTION PROCEDURES SHALL CONFORM TO OSHA FACE 8d ® 4" 0/C 8d ® 12" 0/C 0/C W/ 2x SILL W/ 2x BOTTOM <br /> SNOW LOAD IMPORTANCE FACTOR (Is): 1.0 STANDARDS. ANY DEVIATION MUST BE APPROVED BY OSHA PLATE PLATE U <br /> THERMAL FACTOR (Ct): 4.1 PRIOR TO ERECTION. <br /> SHEARWALL NOTES <br /> 4. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL 1. ALL STUDS, BLOCKING, TOP AND BOTTOM PLATES SHALL BE HEM-FIR NO. 2 UNLESS (3 <br /> WIND DESIGN DATA CONSTRUCTION PROCEDURES. NOTED OTHERWISE ON PLANS. ALL SHEATHING EDGES MUST BE BACKED WITH 2x OR WIDER 0 <br /> 1. BASIC WIND SPEED: 85 MPH G FRAMING (SEE NOTE #3). r7 <br /> 2 WIND IMPORTANCE FACTOR (Iw): 1.0 5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING H L Co w-0) E <br /> BUILDING CATEGORY: II THE WORK OF ALL TRADES AND SHALL CHECK ALL DIMENSIONS. 2. SHEATHING MAY BE INSTALLED EITHER HORIZONTALLY OR VERTICALLY. ALL SHEARWALL 04 0 <br /> 3. WIND EXPOSURE: B ALL DISCREPANCIES SHALL BE CALLED TO THE ATTENTION OF E SHEATHING MUST EXTEND TO THE OUTISDE EDGE OF ALL HOLDOWN POSTS AND CORNERS, Q Q oNo +0 <br /> 4• IKztNTERNAL <br /> = 1.38 THE ENGINEER AND BE RESOLVED PRIOR TO PROCEEDING WITH AND TO THE INSIDE EDGE OF FRAMING AROUND OPENINGS. of am r) <br /> 5. INTERNAL PRESSURE COEFFICIENT: NA THE WORK. - w <br /> 6. APPLICABLE WIND PRESSURE FOR 3. WHERE SHEATHING NAILING IS SHEARWALL #3 AND GREATER, ALL FRAMING MEMBERS U > <br /> COMPONENTS AND CLADDING: NA 1 `•'.'*..� ;.:: :..•: :�.•,•.;,. _ N <br /> 6. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF •, y. RECEIVING EDGE NAILING FROM ABUTTING PANELS SHALL NOT BE LESS THAN A SINGLE .�} v <br /> 7. BASE SHEAR = 14.59K (FRONT - REAR) CONSTRUCTION. WHERE CONDITIONS ARE NOT SPECIFICALLY J. ` '+ 3-INCH NOMINAL MEMBER. ADDITIONALLY, WHERE SHEARWALLS ARE SHEATHED ON BOTH v <br /> 19.92K (SIDE TO SIDE) INDICATED BUT ARE OF SIMILAR CHARACTER TO DETAILS SHOWN, s, �� L• .;,'.:.. FACES, ALL STUDS AND PLATES RECEIVING EDGE NAILING FROM BOTH FACES MUST BE A cD Lil N <br /> SINGLE 3-INCH NOMINAL MEMBER OR PANEL JOINTS MUST BE STAGGERED, IN EACH OF O a)Z 3 SIMILAR DETAILS OF CONSTRUCTION SHALL BE USED SUBJECT TO THESE CASES 3x STUDS ARE REQUIRED UNLESS SPECIFICALLY NOTED OTHERWISE ON THE - w O= 3 <br /> REVIEW BY THE ENGINEER. <br /> SESIMIC DESIGN DATA <br /> 1. SEISMIC IMPORTANCE FACTOR: 1.0 PLANS BY THE ENGINEER. FOR SHEARWALLS 3 AND #4, A 2x SILL PLATE MAY BE USED p CL <br /> SEISMIC USE GROUP: I 7. ALL DETAILS DESIGNATED AS STANDARD OR TYPICAL SHALL ®DOUBLE TOP PLATE W/ EDGE NAILING ©HOLDOWN PER SCHEDULE AND IF TWO TIMES THE NUMBER OF ANCHOR BOLTS REQUIRED BY THE SHEARWALL SCHEDULE <br /> 2. SPECTRAL RESPONSE ACCELERATION (Ss): 130.0% G OCCUR IN ADDITION TO ANY OTHER SPECIFIC DETAIL CALLED (STAGGER) PLAN (HDQ8-SDS3 SHOWN) ARE USED AND ARE EVENLY SPACED (SEE 2003 IBC SECTION 2305.3.10). <br /> 3, SITE CLASS: D (ASSUMED) OUT. ®SHEARWALL EDGE NAILING AT ALL PANEL ®COORDINATE ALL STUD AND 4"' <br /> 54.. SEISMIC DESIGNRESPONSE <br /> COEFFICIENTS R (SDS): 110.0%G 8. ALL INFORMATION SHOWN ON THE DRAWINGS RELATIVE TO EDGES. BLOCKING AT ALL PANEL EDGES PLATE SIZES w/ SHEARWALL 4. SHEARWALL NAILING CRITERIA IS BASED ON TABLE 2306.4.1 OF THE INTERNATIONAL U <br /> WHERE APPLICABLE. SCHEDULE REQUIREMENTS BUILDING CODE (FOR CDX) OR REPORT NER-124 (FOR OSB). VALUES ARE BASED ON <br /> -FORCE-RESISTING SYSTEM: SHEARWALLS EXISTING CONDITIONS IS GIVEN AS THE BEST PRESENT ©EDGE NAILING TO HOLDOWN POST(F <br /> 6. BASIC SEISMIC ULL <br /> 7. SEISMIC RESPONSE COEFFICIENT (Cs): 0.1 KNOWLEDGE, BUT WITHOUT GUARANTEE OF ACCURACY. WHERE HEIGHT) STAGGER INTO DOUBLE STUDS OJ EDGE NAILING TO POSTS, TRIM HEM-FIR NO. 2 FRAMING WITH COMMON NAILS.-FOR <br /> 8. RESPONSE MODIFICATION FACTOR (R): 6.5 ACTUAL CONDITIONS CONFLICT WITH THE DRAWINGS, THEY SHALL ®STUDS ® 16" ON CENTER STUDS, AND KING STUDS 5. HOLDOWNS AND OTHER CONNECTIONS MAY BE REQUIRED AT THE ENDS OF MANY Cn <br /> ALENT LATERAL FORCE <br /> 9. ANALYSIS PROCEDURE USED: EQUIV BE BE MADE. TFICAT THE EN INFERTO SO THE <br /> PROPER DETAILS SHALL REVISIONS MAY ®PRESSURE TREATED SILL PLATE WITH ®BEARING STUD FOR HEADER SHEARWALLS. SIZES AND LOCATIONS OF THESE CONNECTORS ARE INDICATED ON THE <br /> NOT BE MADE WITHOUT PRIOR WRITTEN APPROVAL BY THE EDGE NAILING AND ANCHOR BOLTS PER PLANS. REFER TO THE APPROPRIATE DETAILS AND/OR HOLDOWN SCHEDULE FOR <br /> PROCEDURE SHEARWALL SCHEDULE. ®RIMJOIST TO BE tYz" MIN ADDITIONAL INFORMATION REGARDING ANCHOR BOLTS, EMBEDMENT LENGTH, ETC. WHERE (2) <br /> ENGINEER. ®TOP PLATE SPLICE NAILING TO BE (8) 16d THICKNESS AT ALL 2x's ARE USED AS A HOLDOWN POST, SHEARWALL EDGE NAILING MUST BE STAGGERED INTO <br /> SINKERS (MIN). LAP 48" MINIMUM. CENTER SHEARWALLS EACH MEMBER OF THE POST. m <br /> SPLICE ON STUD. <br /> FRAMING LUMBER 6. ANCHOR BOLTS MUST BE EMBEDDED A MINIMUM OF 7" INTO CONCRETE OR GROUTED w <br /> 1. FRAMING LUMBER SHALL BE HEM-FIR NO. 2. GRADES ARE <br /> STD SHEARWALL ELEVATION W/ RIM CMU, AND SHALL BE PLACED TO PROVIDE A MINIMUM OF 2" COVER. PROVIDE 3" COVER I I a <br /> TYPICAL UNLESS OTHERWISE NOTED ON PLANS. LUMBER TO ~ <br /> BE GRADE MARKED PER WCLIB SPECIFICATIONS. SCALE: =1-0" FOR CONCRETE CAST AGAINST SOIL. p <br /> N <br /> 7. ALL MACHINE BOLTS SHALL BE ASTM A307 OR BETTER. HILTI KWIK BOLTS/SIMPSON I z <br /> 2. STRUCTURAL SHEATHING SHALL BE APA RATED PLYWOOD, TITEN HD BOLTS OF THE SAME DIAMETER AS SHOWN IN THE SHEARWALL SCHEDULE MAY BE uj <br /> EXPOSURE 1 SHEATHING CONFORMING TO EITHER COMMERCIAL SUBSTITUTED FOR ANCHOR BOLTS INTO EXISTING CONCRETE. BOLTS SHALL BE EMBEDDED A <br /> STANDARDS P51-83, APA PRP-108, OR VOLUNTARY PRODUCT <br /> MINIMUM OF 5" INTO EXISTING CONCRETE. <br /> STANDARD PSE-92. PROVIDE A MINIMUM OF 36 EDGE <br /> DISTANCE ON ALL <br /> NAILS 8. ALL NAILS AND CONNECTORS IN CONTACT TH PRESSURE TREATED WOOD (EXCEPT FOR <br /> ALL PANELEDG S. MINIMUM S EATH NAG RI JOINTON EQU REMENTS ARE N WI <br /> BORITE TREATED WOOD) MUST BE HOT DIPPED GALVANIZED OR STAINLESS STEEL TO RESIST <br /> AS FOLLOWS: CORROSION. <br /> (n <br /> ROOF SHEATHING TO E OR INT-APA RATED PLYWOOD 9. WHERE 10d NAILS ARE SPACED AT 3" ON CENTER OR LESS, NAILS MUST BE STAGGERED. L.I <br /> OR ��Ss" OSB WITH EXTERIOR GLUE, P.I. 24/0. NAIL WITH � <br /> Sd NAILS AT 6" ON CENTER AT PANEL EDGES AND 12 10. OSB OF EQUAL OR GREATER THICKNESS MAY BE SUBSTITUTED FOR CDX SPECIFIED IN ON CENTER AT INTERMEDIATE MEMBERS. <br /> SHEARWALL SCHEDULE. LLJ W (A 04 <br /> SUB FLOORING TO BE W TONGUE AND GROOVE C-D EPDXY HOLDOWN SCHEDULE00 <br /> INT-APA RATED PLYWOOD OR OSB WITH EXTERIOR GLUE, *FOR EPDXY INSTALLATIONS INTO EXISTING CONCRETE O w}0)P.I. 48/24. GLUE AND NAIL WITH 10d NAILS AT 6" ON <br /> CENTER AT PANEL EDGES AND 12" ON CENTER AT MODEL ANCHOR FASTENERS TO EMBEDMENT MIN. EDGE a_ w 3 <br /> INTERMEDIATE MEMBERS. BOLT POST LENGTH DISTANCE <br /> 3. NAILING SHALL CONFORM TO TABLE 2304.9.1 OF THE HDU2-SDS2.5 r 0 ATR (6) Y1 SCREWS x 2 �" SIDS7 �" 1�4 HOLDOWN POST. SEE HOLDOWN LENGTH OF FOR DOUBLE SIDED SHEARWALLS, THE LLJ r)w <br /> SCHEDULE OR PLAN FOR MINIMUM SHEARWALL SHEATHING ON EACH FACE MUST EXTEND <br /> INTERNATIONAL BUILDING CODE UNLESS NOTED OTHERWISE: (10) Y:' x 2 �" SIDSUSE COMMON NAILS THROUGHOUT UNLESS NOTED OTHERWISE. HDU4-SDS2.5 J" 0 ATR 12 �" 1�4" REQUIREMENTS CONTINUOUS BETWEEN HOLDOWN POSTS o w <br /> SCREWS AS SHOWN. w <br /> 4. NO STRUCTURAL MEMBER SHALL BE CUT OR NOTCHED Q <br /> UNLESS SPECIFICALLY DETAILED OR APPROVED IN WRITING BY HOLDOWN <br /> NOTES BOLTS SHALL CONFORM TO ASTM A307. U <br /> THE STRUCTURAL ENGINEER. OPENING PER PLA <br /> LOCATION OF # <br /> 5. PROVIDE PROPERLY SIZED WASHERS UNDER HEADS AND 2. MINIMUM CONCRETE COMPRESSIVE STRENGTH f c = 2500 PSI. MINIMUM WALL THICKNESS IS 8". HOLDOWN TO BE <br /> NUTS OF ALL BOLTS AND LAG SCREWS BEARING ON WOOD. INSTALLED STHD14RJ <br /> 3. ALL HOLDOWNS REQUIRE A (2) 2x POST UNLESS NOTED OTHERWISE. WHERE HOLDOWNS ARE INSTALLED INTO THE \ <br /> WIDE FACE OF THE STUD, STUDS MUST BE STITCH NAILED TOGETHER w/ 16d SINKERS STAGGERED ® 4" o/c. TYPE OF HOLDOWN TO BE INSTALLED <br /> 6. PROVIDE 3"x3"x0.229" WASHERS AT ALL ANCHOR BOLTS <br /> 4. MINIMUM EDGE DISTANCE IS FOR FORMED CONCRETE EXPOSED TO WEATHER OR SOIL. FOR CONCRETE CAST AGAINST SHEARWALL DES13NATION - SEE SHEARWALL COVE <br /> 7. BOLT HOLES SHALL BE NOMINAL DIAMETER OF BOLT PLUS SOIL PROVIDE 3" CLEAR TO ANCHOR BOLT. SCHEDULE FOR FRAMING, NAILING AND 4t9 opW.v C> <br /> ;16" UNLESS NOTED OTHERWISE. LAG DOLT PILOT HOLES ANCHORAGE REQ'JIREMENTS <br /> SHALL BE PRE-DRILLED TO 60% OF THE NOMINAL DIAMETER 5, NAILS/SCREWS TO HOLDOWN POST SHALL BE PER MANUFACTURER'S SPECIFICATIONS. LATERAL MARKING LEGEND - <br /> OF THE LAG BOLT UNLESS:NOTED OTHERWISE. <br /> 8. ALL SILL PLATES SHALL BE BOLTED TO THE FOUNDATION 6. WHEN FIELD CONDITION BECOME LESS THAN MINIMUM SHOWN, CONTACT ENGINEER PRIOR TO PROCEEDING. <br /> �h 3* <br /> WITH 5#8" MINIMUM DIAMETER BOLTS SPACED AT A MAXIMUM 7, ALL HOEDOWN BOLTS MUST BE RE-TIGHTENED JUST PRIOR TO ENCLOSING SECOND SIDE OF WALL. <br /> OF 48" ON CENTER. BOLTS MUST BE EMBEDDED A MINIMUkA <br /> OF 7" INTO CONCRETE OR MASONRY. SEE PLANS AND S. HOLDOWNS MAY BE ATTACHED TO EXISTING CONCRETE USING SIMPSON 'SET-XP' HIGH STRENGTH EPDXY. SIZE AND Ui41IR$2]INLY <br /> DETAILS FOR SPECIFIC REQUIREMENTS WHERE APPLICABLE. EMBED PER CHART. ICBO REPORT NO. ER-5279. DRILL ANCHOR BOLT HOLES V LARGER THAN ANCHOR BOLT DIAMETER. - <br /> Drawn By. CHRIS <br /> 9. RIM JOIST IS TO BE 11#4" LSL MINIMUM. Checked By.CHRIS <br /> Date:02-22-22 <br /> 10. PROVIDE DOUBLE JOIST UNDER ALL PARALLEL PARTITION <br /> WALLS AND SOLID BLOCKING UNDER PERPENDICULAR PART71ON <br /> SDA JOB NO. <br /> WALLS. <br /> 9476 <br /> 11. CONTACT THIS OFFICE PRIOR TO MAKING ANY CHANGE` TO <br /> THESE DETAILS <br /> STRUCTURAL <br /> NOTES/DETAILS <br /> S- 1 . 0 <br />