My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6003 23RD DR W 2025 Plans 2025-09-16
>
Address Records
>
23RD DR W
>
6003
>
Plans
>
6003 23RD DR W 2025 Plans 2025-09-16
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/16/2025 3:38:17 PM
Creation date
9/16/2025 3:38:08 PM
Metadata
Fields
Template:
Address Document
Street Name
23RD DR W
Street Number
6003
Permit
B2503-049
Year
2025
Notes
TI: install partitions walls/ doors, no footprint change
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
3
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
_-_... ... .. ...�>.. L <br /> City of Everett Permif Services <br /> EVERETT Reviewed for Permit /28/2025 <br /> WASHINGTON <br /> 7T, N <br /> © <br /> V N <br /> N <br /> � � v <br /> I <br /> s <br /> MATERIALS: <br /> 1/2"GYPSUM WALLBOARD complying with IBC 2506.2 and 2508.1 with 1-15/8"fasteners installed per Table 2508.1,GA 216;ASTM C840. <br /> Door hardware shall be level type,fully accessible IBC Chapter 11;ANSII 117.1-2017 <br /> Door leaf shall be accessible, MIN 32-INCH CLEAR WIDTH <br /> 2021 WASHINGTON BUILDING CODE: <br /> a <br /> 2308.5.4 Nonload-Bearing Walls and Partitions <br /> I I <br /> In nonload-bearing walls and partitions,that are not part of a braced wall panel,studs shall be spaced not more than 24 inches(610 mm)on <br /> center. Interior nonload-bearing partitions shall be capped with not less than a single top plate installed to provide overlapping at corners and j <br /> at intersections with other walls and partitions.The plate shall be continuously tied at joints by solid blocking not less than 16 inches(406 mm) <br /> in length and equal in size to the plate or by 1/2-inch by 11/2-inch(12.7 mm by 38 mm)metal ties with spliced sections fastened with two 16d <br /> nails on each side of the joint. <br /> 2308.5.5.3 Openings in Interior Nonbearing Partitions <br /> Openings in nonbearing partitions are permitted to be framed with single studs and headers. Each end of a lintel or header shall have a <br /> bearing length of not less than 11/2 inches(38 mm)for the full width of the lintel. HEADERS shall be designed for the span per IBC table <br /> 2308.4.1.1 (1) <br />
The URL can be used to link to this page
Your browser does not support the video tag.