Laserfiche WebLink
Permit#: FA2406-022 ? <br /> Site Address: 10200 25th Ave BE <br /> ica <br /> DSFNHOWFR V0DLE <br /> App,ammni Fire Protection lncFIREPR-290-90N INC. <br /> SCHOOL Application Date:06/25/2024 17410 Ash Way,Ste 8 <br /> 600 <br /> Description: Installation of a Wireless Fire Alarm Lynnwood,WA Ste 8 <br /> 37 <br /> Communicator ISEAT LE.0 <br /> Review Date: 06/26/2024 <br /> WRELESS <br /> NSTALLA70N <br /> tTT FPISEATTLE.COM <br /> E�E <br /> COVVUN � CATOR EverettSt eseApproved rk <br /> Reviewed By:KBrovm <br /> 06/26/2024 1:54:23 NFPA® <br /> PM <br /> OPERATIONAL MATRIX TELGUARD INSTALLATION DETAIL SHEET INDEX 000805173 <br /> ROY L CATS <br /> SHEET # SHEET DESCRIPTION AlQp0TECTjO <br /> FA 0.0 FIRE ALARM : TELGUARD INSTALLATION o`Q <br /> ,�1, 9 <br /> SYSTEM OUTPUTS u+ In <br /> Required Fire Safe Control <br /> Central Supervising Station <br /> mm PROJECT DETAILS �'y�J NFPA yam^ <br /> Control Unit Annunciation 1. THE EXISTING SINGLE STORY BUILDING IS FULLY SPRINKLED AND HAS AN EXISTING ADDRESSABLE FIRE CFPS <br /> oc �m ALARM CONTROL PANEL LOCATED IN THE MAIN OFFICE. #1473 <br /> c <br /> °c y Oc IF mm ® 2. ANEW UL LISTED WIRELESS CELLULAR COMMUNICATOR (HW—TG7LAF02/TG7LVF02) IS BEING INSTALLED AT <br /> THE FACP. ALL SIGNALS WILL BE TRANSMITTED BY ZONES TO THE UL LISTED SUPERVISING STATION. <br /> (D O O O O O 3. THE NEW CELLULAR COMMUNICATOR SHALL TRANSMIT THE EXISTING FACP ZONES. Qe <br /> 9 <br /> 2o y�Q � 4. NO CHANGES TO THE EXISTING SYSTEM WILL BE MADE, NO ADDITIONAL WORK IS INCLUDED IN THIS SCOPE ## a <br /> 0 of o .'g 2 Q nwwmam y� w <br /> em a'� cm a mom . O 0 CONTACT INFO w=N W <br /> ED OWNER/TENANT FIRE ALARM CONTRACTOR a r <br /> SECURE PACIFIC CORPORATION FIRE PROTECTION INC Z p 0 <br /> METAL 8220 NORTH INTERSTATE AVE 17410 ASH WAY, Ste 8 i o rc <br /> �air <br /> :��~�°3mm PORTLAND, OR 97217 LYNNWOOD, WA 98037 c u a <br /> Q Q m 4i CONTACT : TAYLOR PEACOCKE CONTACT : DAVID MOW <br /> PHONE : 888.508.2780 PHONE : 425.290.9600 z a 0 <br /> w <br /> m F <br /> TPEACOCKE®SECUREPACIFIC.COM DAVIDC�FPISEATTLE.COM m O u ur o <br /> o z 3 J V W f <br /> SYSTEMINPUTS B D IF <br /> 1 Manual Fire Alarm Pull-Station <br /> w x a m <br /> IN CODE INFORMATION w w ro wo 'a <br /> 1 0 1I m <br /> K <br /> 2 Smoke&Heat Detectors 2 TET�IUARDIIW TG�111(1�F02 REVISION RECORD <br /> Q 3 Wet Waterflow ��� 3 AUTHORITY HAVING JURISDICTION CITY OF EVERETT DATE DESCRIPTION <br /> 4 Unused 4 FIRE CODE : INTERNATIONAL FIRE CODE, 2021 EDITION <br /> CIL 5 Sprinkler Tampers 5 BUILDING USE AND OCCUPANCY : (E) — FULLY SPRINKLED <br /> N 6 PIV 6 <br /> 7 Fire Alarm AC Power Failure 7 STANDARDS: 2021 IBC/IFC, 2017 NFPA 70, 2016 NFPA 72, CITY OF EVERETT STANDARDS <br /> In 8 Fire Alarm System Low Battery 8 CLASSIFICATION OF SUPERVISING STATION : CENTRAL SUPERVISING STATION <br /> H 9 Open Circuit 9 REMOTE SUPERVISING STATION : SECURE PACIFIC, EVERETT WA <br /> 10 Ground Fault 10 <br /> A B C D E F G H I EXISTING FWE�Mpq�, PRIME FIRE ALARM CONTRACTOR FIRE PROTECTION INC <br /> PARCEL NUMBERS 28052000200900 <br /> INSTALLATION NOTES <br /> TYPICAL WIRING AND INSTALLATION DETAILS <br /> VICINITY MAP 1. ALL WORK SHALL BE IN ACCORDANCE WITH NFPA STANDARDS AND ALL LOCAL ADOPTED CODES. <br /> 2. ALL CIRCUITS MUST BE TESTED FOR OPENS, CONTINUITY, SHORTS, AND GROUNDS. <br /> 3. INSTRUCTIONS FOR THE OPERATING, TESTING AND MAINTENANCE OF THE SYSTEM, ALONG WITH RECORD <br /> DRAWINGS OTHERWISE REFERRED TO AS ("AS—BUILT") AND EQUIPMENT SPECIFICATIONS SHALL BE <br /> JIL PROVIDED TO THE OWNER ONCE THE FIRE ALARM SYSTEM HAS BEEN ACCEPTED BY THE AHJ. . <br /> - SITE PLAN <br /> 4. ALL SYSTEMS AND DEVICES SHALL BE INSTALLED AND TESTED PER THE MANUFACTURES LISTING AND THE <br /> AUTHORITY HAVING JURISDICTION (NFPA72 10.14.2.1). <br /> '. Granite Falls 5. THE SYSTEM WILL BE 100% PRE—TESTED, AN NFPA 72 COMPLETION FORM WILL BE FILLED OUT AND <br /> PROVIDED TO THE AHJ AND THE ELECTRICAL PERMITS MUST BE SIGNED OFF PRIOR TO THE FIRE FINAL DATE: 06/24/2024 <br /> INSPECTION. PROJECT NAME <br /> Marysville 92 6. THE CELLULAR COMMUNICATOR REQUIRES A DEDICATED 120VAC 20AMP CIRCUIT. A NOTICE PLACED IN THE <br /> 10 TH ST SE FACP SHALL DIRECT PERSONNEL TO THE LOCATION OF THE ELECTRICAL PANEL THAT IS SUPPLYING <br /> DEDICATED POWER TO THE SYSTEM (NFPA72, SECTION 10.5.5.1). THE DEDICATED CIRCUIT BREAKER THAT <br /> Lake Stevens SERVES THE FIRE ALARM SYSTEM SHALL BE LABELED AND SECURED AGAINST TAMPERING WITH A RED J <br /> - a BREAKER LOCKOUT (NFPA72, SECTION 10.5.5.2). O <br /> 2 <br /> Everett L) Lu 00 <br /> 04 <br /> DEVICE INSTALLATION REQUIREMENTS W W 00 <br /> J CA <br /> 2 Q Q Q <br /> Eisenhower _ <br /> Middle School FIRE ALARM DEVICE INSTALLATION REQUIREMENTS N <br /> NOT PERMITTEDLLI <br /> BRACKET DIFFUSER HERE a" CD <br /> 3: C X <br /> GRID II O CVO W <br /> Monroe ELECTOR <br /> DEVICE DCEILING'My ETECTOR I ICl1 SMOKE W <br /> Z <br /> OUTDOOR L AWAY FROM NOT PERMITTED 4 11J <br /> - HORN/STROBE HVAC DIFFUSERS HERE t 12 <br /> M � IJ.I <br /> H S SMOKE <br /> =tl onds <br /> S22 <br /> MAX HEIc„T sz^A.F.F IN SHEET TITLE <br /> y FACP MIN HEIGHT 82"A.F.F <br /> J m <br /> Shoreline orthell FAA I FIRE ALARM <br /> FACE ® O — PROJECT DETAILS <br /> 66"A.F.F 60"A.F.1 F.. <br /> ® <br /> r 'V SHEET NUMBER <br /> T Not to Scale <br /> INI H L <br /> FA 0.0 <br />