Laserfiche WebLink
------ Air <br /> SELF ADHESIVE / PER I <br /> i l �-SLIL11 GLa 'NCI: EXTEND MIN.6"UP JAMB <br /> FLASHING <br /> E PAN �'' / / NAIL FA%il <br /> NAIL ON FL-XiBLE / -- - GALJ NERVASTRAL TO EXTEND <br /> 2'PAST THE <br /> FLASHING ---- �\ �% / --2 I,V FRLi' L bF OF THE DOORINTERIOR \ HEADER/ \ HEADER/ <br /> FLOOR JOIST LEG cK T.'.' REIN STUD <br /> PER P;.AN-._...- \ _. i i ;---5/4 H EDAF E .'�idG <br /> \�\ - PER PLAN WA fir ROUGH <br /> ROUGH <br /> OPENING <br /> OPF <br /> 1 BARRIi:, , <br /> - x '018'. _n rLAPI JAMB V JAMB\ <br /> .I ---HAN t. PER FLAN JOINI PIECE <br /> / SILL A / SILL A <br /> j/' N5TAt., r <br /> -_� IN MUCERAIE _ PENETRATION <br /> RIM JOIST _.-._._-- PT L aER r..�.uJ CONT i y bu <br /> BUILDING PAPER- I 5NEATHING PL 12• SILL Q-�I'^ <br /> INSTALLED BEHIND SIDING=eF. FLASHING <br /> LEDGER AND PAN '__._SIDING PER PL.A PLAT, BUILDING PAPER TO EXTEND <br /> FLASHING.LAP <br /> OVER HOUSE WRAP LEDGER INSTAL:.tD EE IE MIN.12'BEYOND ALL EDGES STEP I STD. <br /> W/BUILDING PAPER BE:11 av .. EXTEND 12"BEYOND - OF THE PENETRATION , <br /> R ATTACH SILL STRIP OF 9'WIDE MOISTOP OR EQ, FLASHING MATERIAL •ATTACH JAMB STRIPS OF 9°WIDE MOISTOP OR EQ.).( ) ( Y . L <br /> EXPOSED ON ALL a SIDES 1� �, OPENING WITH THE TOP EWE EVEN WITH THE TOP OF THE ROUGH SILL. FLASHING MATERIAL WITH INSIDE EWE EVEN WITH THE JAMB <br /> •EXTEND THIS STRIP AT LEAST 12'BEYOND THE EDGE F THE ROUGH OF THE ROUGH OPENING, <br /> •START JAMB STRIPS 2"BELOW SILL STRIP AND EXTEND 6' <br /> (/W22 DECK LEDGER DETAIL _ �Ii\ �,,1 FLASHING EXTERIOR DOOR FLASHING PENETRATION PROTECTION •AT ACH FLASHING MATERIAL WI"FH CORROSION-RESISTANT STAPLES. ABOVE LOWER EWE F HEADER. <br /> CD <br /> SCALE:N.T.S. W14 SCALE:N.T.S. (— _ <br /> F57. <br /> Nre iR11 <br /> FRpR mx CONT.BEAD OF <br /> s�wsu� --HEAD ___ --._--SEALANT LLA <br /> EQ. EQ. FLASHING UNDER NAIL FIN ( 1T <br /> _ 2� 2� <br /> FIXED <br /> SGD PER PLAN <br /> i OPERABLE <br /> L PANEL PANEL ..J -- CUT AWAY El <br /> LINE OF �.—� --=: WINDOW __..._ .____EXCESS WINDOW LI-- <br /> FRAME OR BLDG.PAPER <br /> NRVESTRAL __ __ ____ Y"N NEARTHOOD CEDAR TRIM, FRAME OR <br /> BEHIND EQ.ALL SIDES,fAULK/SEAL SIMILAR OPENING SIMILAR L-L-� <br /> L' PRO TO HOSE BIB_ EQ, p' EQ, OPENING <br /> 5'6 <br /> 3'-6'TO BOTTOM s�xa�LANDING rIT'. *NOTE; SEAL ALL <br /> Of '•, - POUR AGAINST BUILDING----- -- f <br /> C.LNTF NRVASTRAL EXPOSED FASTENERS <br /> BEND FRONT PORCH PATIO SHEATHING PER PLAN BUILDING PAPER - <br /> ELELTRICA- 3'-6'LANDING TYP. TYP <br /> ER TYP <br /> METER MAIN °• P""a'�C1L0"�'"'s LINE OF &IILDING PAPER <br /> e- P BACK PAT ceRv I"TMe nll z INSULATION BLW PAPER -_- <br /> n nrz rom sloe a TME NAIL FLANGE UNDER SILL STRIP <br /> s<.o,rsxxsvu Faelms PER PLAN <br /> PRONTO BEND APPROVED FLASHING <br /> FRONT -- DOOR - zxc HEARTWOOD CEDAR rRln (0.19 x I0'ROLL) <br /> INSTALLED ON •APPLY� A 3/B"CONTINUOUS BEAD OF CAULK TO THE BACK OF THE FRAME APPLY THE NEXT COURSE OF BUILDING PAPER BUTTING TO THE <br /> CORNER - LANDING PER PLAN FAIR <br /> OF DOUSE IjXj,OF HOUSE THRESHOLD AGAINST NR—RAL ylG NEARTWWD CEDAR <br /> SIDING PER PLAN I-I/2"GAP NAILING FLANGE AT ALL SIDES OF THE WINDOW FRAME O;EN1NG)OVER THE JAMB FLASHING MATERIAL. <br /> 304 FEL .I'C., ._._________ TRIM w/FLASHING a co <br /> AT GARAGE HOSE I HOUSE miERSECTION, �$' BTWN ROOF AND SIDING .PLACE AND SECURE FRAME INTO ROUGH OPENING WITH FLANGES OVER THE •APPLY SUCCEEDING LAYERS OF BUILDING PAPER IN SHINGLE W NRVESTRAL — <br /> BIBS STARTEh :I r.Ir -1.7JIDIN4 PEa P.hv _ _ WHERE X-URS INSTALLED JAMB AND SILL!JAMB MOISTOP(OR EQ.)FLASHING MATERIAL. BOARD FASHION UP THE WALL,LAPPING COURSES A MINIMUM OF <br /> INSTALL (MIN. 5 TQ-, ROOF SHINGLES .NAIL WINDOWS PER WINDOW MANUFACTURER'S SPECIFICATIONS 1/2 PAPER WIDTH. <br /> GROUNDING -v OF STEPS MID BY -- LINE OF NRVESTRAL •STARTING FROM THE BASE OF THE WALL,APPLY BUILDING PAPER UNDER <br /> FLASNIN, Muo s1u DrnaNs I 30R FELT TO EXTEND UP THE SILL STRIP AND CUT ANY EXCESS BUILDING PAPER THAT MAY EXTEND <br /> ROD 12"FROPI t. _ -_—__ WALL I2'MIN. \\ <br /> PRONTO BEND WUL ,TE toN DE :A�FORT FLASH STE THE BILL D BETWEEN T14E JAMES OF THE E BOTH SIDES OF WINDING <br /> FORTkLASH c/FLASHING cee rm rsolr " �- <br /> 4 Mi-:.1 C': FASCIA I .1.::J LANROOF TRUSS -111 s' L APPLY SLFED 2B GA 2 BACK,PREFINISHED METAL FLASHING 70 OPENING.µNO f1015TOP.TURN ,' - - SLAB 'RA <br /> µD rRaT Fay cerAIL �\ ----ROOF SHEATHING PER PLAN •APPLY 6'FORTIFLASH OVER TOP HEAD FLANGE OF WINDOW.EXTEND PAST <br /> GLITTER I k <br /> ALL <br /> 51DESH ONTO PANEL, - - EXT. LANDING DETAIL @ �—ROOF TRUSS <br /> FLL SIDES t CORNERS � JAMB FLASHING 2'. � -_6 <br /> F A5HI l.; - @ EAVE SLIDING GLASS DOOR, TYP �� ROOF TO WALL FLASHING ��STANDARD FLASHING MATERIAL APPLICATION AT OPENINGS_ 0 11 I. <br /> P I- <br /> 2x2 TRIM i PERIMETER - ly <br /> OPENING FOR EXEC.- v.E!.L'� �,al..Iv::, WIL SCALE:N.T.S. VVII SCALE:N.T.S. YVIV SCALE:N.T.S. <br /> METER BOX,FIREPLACE PA N EEHINI; <br /> DIRECT VENT,RANGE VENT, METER MA.I:I SEALANT—� WINDOW FRAME ('(1 <br /> DRYER'VENT, ETC. INSULATION 7/16'PLYWD.SHEATHING <br /> +SEE DETAIL WIU FOR IYOISTOP INSTALL IdSTRbC"I"ICNS SILL ASSEMBLY 3/8"BEAD CAULK <br /> PER SPEC SEALANT qq (WHERE OCCURS) 6'FORTIFLA5H 0/FLASHING <br /> ELECTRIC METER it HOSE U1_D' TRIM PER ELEVATION GYP.BD. ND.FRAME WALL 51DING PER PLAN <br /> C� _LOCATION NO GAS METER) <br /> - (WHERE APPLICABLE) INSULATION PER PLAN - - -- --BUILDING PAPER <br /> TRIMMER (WHERE OCCURS) R-10 INSULATION - --M015TOP(SEE DETAIL WIIO <br /> 5CALE:N.T 5. <br /> MOISTOP SEE DETAIL <br /> GYP.BD. ( KING STUD BEHIND HDR, TYP p FOR INSTALL) <br /> WIN)FOR INSTALL) WD.FRAME WALL ALL HDR's MIN.114"GAP BTWN SIDING <br /> SEALANT PER PLAN I / AND FLASHING MOISTOP(SEE _ COPMQ4T NOTICE THIS <br /> 'MIN.IB' EXT WALL PER GYP.BD.---- _\ <br /> PLAN SIDES <br /> OF <br /> PALL FOR ALL) - 7/Ib"PLYWD.SHEATHING HEADER PER PLAN ------ - -F L "7 PLAN I5 OWNED USE <br /> PACIFIC <br /> _ ASHING TURN DOWN RIDGE HOMES.USE of TVI15 <br /> J "AT EACH ENDWTWOU— PLAN 15 P HYMEN Eo BY LAw <br /> / / LICENSE <br /> I PAYMENT 01 <br /> CI <br /> n - INSULATION ' I LICENSE FEE TO PACIFIC <br /> WINDOW FRAME TRIM PER ELICABLE) I\ RIDGE HOMES <br /> BLDG.PAPER APR TYP. (WHERE OCCURS) '.� BLDG.PAPER SEE ELEV.FOR (WHERE APPLICABLE) <br /> JEDGE <br /> / 0'-6"TO HOSE BIB 'ER PLAN ' SEALANT SIDING PER PLAN WINDOW HT)B'-b"TO C,L, 7/Ib"PLYWD.5NEATHING TRIM PER ELEVATION-SEALANT � PLAN SUr1f1ARY <br /> Ir 1ED TRIM ' WHERE APPLICABLE FORTIFLASH ON ALLSEALANTOF PRONTO BEND --- ( ) SIDES OF WINDOW WINDOW FRAME3=6 - 3'-°" � )RNER �WINDOW SILL @WOOD FRAME WALL P�WINDOW JAMB DETAIL WINDOW HEAD DETAIL TO EWE 70 �' Lla 1.I-T ""'" <br /> EWE EWE �, EL ER i,`I. ..0 l e v SCALE:N.T.S. SCALE N.T.S. W6 814 <br /> SCALE N.T.S. <br /> METER:iAlil <br /> FWA - <br /> m.Fl <br /> LAP SIDING, <br /> GARAGE Y A7TALHED OFF ADJOINING NROOF OLD I-I/2• J /-' EQ /- TmK wA <br /> OF HOUSE I, i / � � --"-`"--"- --BOTTOM SOSTUDS @ ac(NO POSTS/ 200cj <br /> / POINT LOADS ABOVE VENTS) <br /> AT GARAGE � ' '! NOSE ) <br /> IU1� 61BB LAG SCREW METAL FLASHING , PLAN -.� 405 <br /> i-GAS (MAY BE STEPPED) .� ---EQ=-' _ wAr eon: <br /> METER NSTAL. .STUDS.LAG .-'� - - /-3/4"Tw SUBFLOORE--- GAS <br /> G,ROWtD;I� O PENETRATE BUILDING PAPER ON -- <br /> _._._ OD I_ �.)`� MIN.,TYP.P SHEATHING(SIDING CUT l <br /> .una.e.lwa n.»mxwlu <br /> FLASHING - JWA <br /> 0 2/3 HT F AWAY FOR CLARITY) Ir - <br /> r 7-1/2"x15-I/2"CEDAR RIM , <br /> FOR7IFLASH u/FURN NG TAS w/I -- i i VENT5 w/GALV SCREEN- <br /> A:ND 11UISTOP.TURN-----� �' v h 1," 4.STRAP MIN METAL RAIN DIVERTER(THE <br /> I'ORTIFLA5H I''ONTO PANEL, PURP05E 15 TO SHED THE '__��� PROVIDE LOU ERED VENT5 BTL ENGINEERING <br /> i:.L SIDES t CORNERS WATER OFF THE ROOF AND - FRONT ELEVATIONS— wxN:un <br /> rL•t�.rJC: dT OF HWT KEEP IT AWAY FROM THE /� ROOF SHINGLES \N--RIM PER PLAN SEE REVISION LOG <br /> 2:c2 TRIM i'+PERIMETER-- 1 7y_ VERTICAL WALL BENEATH). PER SPEC. o <br /> -P.T.MUD SILL--- / SCALE: Y"=I'-0" <br /> OPENING FOR ELEC.-- ` - 60 1''.III ELI IT OF NWT FASCIA PER PLAN w/ �� 30!<ROOF FELT CONCRETE FOUNDATION—/ <br /> METER BOX,FIREPLACE _ PA^2k EEI-I GUTTER <br /> xer moans <br /> DIRECT VENT,RANGE VENT, METER aAb! 7/16'058 ROOF $400 NOT INSTALL VENT($)CLOSER THAN 3'TO GAS METER.. WATER <br /> DRYER VENT, ETC 5HEAT14ING A*BUILDING PAPER SHOULD BE INSTALLED OVER FLA51­1I11G+A INTRUSION <br /> _- __._ DETAILS <br /> *SEE DETAIL HID FOR MO;STOP INSTALL INE V, NOTE PER WSEC R402.2.7:WHEN FOUNDATION VENTS ARE NOT PLACED SO THAT THE TOP <br /> NOTE: SEAL ALL OF THE VENT IS BELOW THE LOWER SURFACE OF THE FLOOR INSULATION,A PERMANENTLY <br /> ELECTRIC GAS METER HVC ATTACHED BAFFLE SHALL BE INSTALLED AT AN ANGLE OF 30'FROM HORIZONTAL,TO <br /> I : USE 3 STRAPS ON 75 GALLON AND GREATER SIZES EXPOSED FASTENERS DIVERT AIR FLOW BELOW THE LOWER SURFACE OF THE FLOOR INSULATION. <br /> �^I BIB CLEARANCES it LOCATION WATER NEATER (HWT) STRAPS <br /> DETAIL <br /> �5 SCALE:N.T.S. SCALE:N.T.S.� @ROOF/WALL INTERSECTION � <br /> SCALE:N.T.S. - ( �VI FOUNDATION VENT f� <br /> SCALE:N.T.S. <br />