Laserfiche WebLink
BTL <br /> 19011 Wood-Sno Road ATE,Suite 100 <br /> Woodinville,WA 98072-4436 <br /> Phone:425-814-8448 <br /> 1: t:1T,,1-,J` 1411-, -; Fax:425-821-2120 <br /> Linton Remodel Revision Date: 1/23/2023 <br /> 23-664-18 <br /> P$=x Kn PS30 (28.5-1) Exposure= C <br /> A= 1.38 (Fig.28.5.1) Mean Roof Ht hn(ft)= 28 ft <br /> Kzr= 1.00 (SeoBon 26.8) a(roof)= 3.0 ft <br /> a(upperlmain floor)= 3.0 ft <br /> Basic Wind Speed= 100 mph <br /> Roof Angle= 27 <br /> NorthiSouth Loading 28.5.4 Minimum Design Loads <br /> Zone Area P.(Pst) P...,.(Pso P(00 Force(4) Aso Force(4) Force(4) ASO Force(N) <br /> Roof A.,,d 24 19.1 19.1 26.3 631 379 384 230 <br /> Agable 15 19.1 19A 26.3 395 237 240 144 <br /> B 0 6.8 6.8 9A 0 0 0 0 <br /> Cwall 64 14,$ 14.3 19.8 1255 759 1024 614 <br /> Cgable 40 14.3 14.$ 19.8 790 474 640 384 <br /> D 0 5.9 5.9 8.1 0 0 0 0 <br /> Total Area= 143 Total Load= 3081 1849 2288 1373 <br /> Design: 3081 1849 <br /> Zone Area P.(Pso P.-(Psi) P(Psi) Force(#) ASD Force r4J Force(9) ASO Force(4) <br /> Floor Await 53 19.1 19.1 26.3 1381 829 $40 504 <br /> Agable 0 19.1 19.1 26.3 0 0 0 0 <br /> 6 0 6.8 6.8 9.4 0 0 0 0 <br /> Cwall 140 14.3 14.3 19.8 2767 1660 2240 1344 <br /> Cgable 0 14.3 14.3 19.8 0 0 0 0 <br /> D 0 5A 5.9 8.1 0 0 0 0 <br /> Total Area= 193 Total Load= 4148 2489 3080 1848 <br /> Design- 4148 1 2489 <br /> East/West Loading 28.5.4 Minimum Design Loads <br /> Zane Area pni (Psl) Psrc-vn(Psi) P(psi) Force(4) ASD Force(4) Force(k) ASD Force(4) <br /> Roof Awall 24 19.1 19.1 26.3 631 379 384 230 <br /> Agable 0 19A 19.1 26.3 0 0 0 0 <br /> 6 30 6.8 6.5 9.4 282 169 240 144 <br /> Cwall 145 14.3 14.3 19,8 2859 1715 2315 1389 <br /> Cgable 0 14.3 14.3 19.8 0 0 0 0 <br /> D 180 5.9 $.9 8.1 1466 879 1440 864 <br /> Total Area= 379 Total Load= 5237 3142 4379 2627 <br /> Design: 5237 3142 <br /> Zone Area P-(Pst) P sruer a�(1351) P(Pso Force(4J ASO Force(a) Force(A) ASD Force(4J <br /> Floor 2 Awall 50 19.1 19.1 26.3 1322 793 804 482 <br /> Agable 0 19.1 15.1 26.3 0 0 0 0 <br /> B 0 6.8 6.8 9.4 0 0 0 0 <br /> Cwall 319 14.3 14.3 19,8 6299 3779 5100 3060 <br /> Cgable 0 14.3 14.3 19.8 0 0 0 0 <br /> D 0 5.9 5.9 8.1 0 0 0 0 <br /> Total Area= 369 Total Load= 7620 4572 5904 3542 <br /> Design: 76ZO 4572 <br /> Zone Area P.(psi) P--,n,(Psf) P(Pst) Force(4) ASD Force(p) Force(4) ASD Force(0) <br /> Floor 1 Awall 53 19.1 19.1 26.3 1381 829 640 504 <br /> Agable 0 19.1 19.1 26.3 0 0 0 0 <br /> 5 0 6.8 6.8 9.4 0 0 0 0 <br /> Cwall 132 14.3 14.3 19.8 2608 1565 2112 1267 <br /> Cgable 0 14.3 14.3 19.8 0 0 0 0 <br /> D 0 5.9 5.9 8.1 0 0 0 0 <br /> Total Area= 184 Total Load= 3989 2394 2952 1771 <br /> Design. 3989 Z394 <br /> Date: 11/8/2023 <br /> Page: L1-4 <br />