Laserfiche WebLink
E:2)/\ L-FH I S R E S I D E N C E - 272 E3 <br /> J <br /> mm <br /> Q <br /> REMODEL/ADDITION <br /> BAD NT W W� <br /> Lw Wat <br /> w L r NNN <br /> IL <br /> r H N N <br /> w H <br /> Uw Uwa <br /> maN <br /> Om W;1 <br /> GENERAL NOTES SHEET INDEX PROJECT TEAM U a San <br /> OWNER Z NON <br /> <_ = <br /> ARCHITECTURAL BALTHIS JOSHUA L&JENNIFER A r w �N <br /> Un N G m <br /> 1.THESE GENERAL NOTES PERTAIN TO WORK DESCRIBED ON ALL CONTRACT DOCUMENTS. N h <br /> 2326 MCDOUGALL AVE. p a f N <br /> 2.THE CONTRACT DOCUMENTS CONSIST OF THE OWNER CONTRACTOR AGREEMENT,THE CONDITIONS OF CONTRACT A0.1 TITLE SHEET EVERETT,WA 98201 f' N V <br /> (GENERAL,SUPPLEMENTARY,AND OTHER CONDITIONS),THE DRAWINGS,THE SPECIFICATIONS,AND ALL ADDENDA ISSUED A1.1 SITE PLAN a y U N 0 Q <br /> PRIOR TO AND ALL MODIFICATIONS ISSUED AFTER EXECUTION OF THE CONTRACT. A2.1 FLOOR PLAN ARCHITECTURAL <br /> 3.CONCEPT ARCHITECTURE,LLC IS THE AUTHOR OF THESE PLANS AND CLAIMS A COPYRIGHT IN THESE PLANS AND THE CONCEPT ARCHITECTURE,LLC. P:(425)377-8786 PROPERTY INFORMATION of <br /> DESIGNS CONTAINED IN THESE PLANS.THIS CLAIM IS MADE UNDER TITLE 17 OF THE UNITED STATES CODE AND ALL APPLICABLE 2911 1/2 HEWITT AVE,SUITE 2, a O <br /> TREATIES AND FOREIGN LAWS.THESE COPYRIGHTED DRAWING FILES ARE TO BE USED FOR REFERENCE ONLY.CONCEPT EVERETT,WA 98201 MREIMERS@CONCEPTARCHITECTURE.COM .W <br /> ARCHITECTURE,LLC WILL TAKE NO RESPONSIBILITY FOR ANY CHANGES MADE TO THESE DOCUMENTS BY ANOTHER PARTY AND .0 <br /> WA 98201 EVERETT, i 3 <br /> NO LICENSE IS GIVEN FOR TRANSFER OF THESE COPYRIGHTS TO ANOTHER PARTY. ADDRESS 2326 MCDOUGALL AVE. r N <br /> 4.THE WORK COMPRISES THE COMPLETED CONSTRUCTION REQUIRED BY THE CONTRACT DOCUMENTS AND INCLUDES ALL APN 00439149501900 o z <br /> LABOR NECESSARY TO PRODUCE SUCH CONSTRUCTION,AND ALL MATERIALS AND EQUIPMENT INCORPORATED OR TO BE SIZE 0.21 ACRES <br /> INCORPORATED IN SUCH CONSTRUCTION. <br /> SUBDIVISION X Q w <br /> 5.SHOP DRAWINGS,PRODUCT DATA AND SAMPLES ARE NOT A PART OF THE CONTRACT DOCUMENTS.THE ARCHITECT WILL w w <br /> REVIEW THEM,BUT ONLY FOR CONFORMANCE WITH THE DESIGN CONCEPT OF THE WORK AND WITH THE INFORMATION GIVEN ZONE R-2 rn s <br /> IN THE CONTRACT DOCUMENTS.THE CONTRACTOR SHALL NOT BE RELIEVED OF RESPONSIBILITY FOR ANY DEVIATION FROM <br /> STHE AMPLESUIREMENTSOFTHECONTRACTDOCUMENTSBYTHEARCHITECTSREVIEWOFSHOPDRAWINGS,PRODUCTDATAOR PROJECT DESCRIPTION =� <br /> Y F <br /> 6.THE CONTRACTOR SHALL CAREFULLY STUDY AND COMPARE THE CONTRACT DOCUMENTS AND SHALL AT ONCE REPORT TO O o <br /> THE ARCHITECT ANY ERROR,INCONSISTENCY OR OMISSIONS HE MAY DISCOVER.THE CONTRACTOR SHALL PERFORM NO ¢ <br /> PORTION OF THE WORK AT ANY TIME WITHOUT CONTRACT DOCUMENTS OR,WHERE REQUIRED,APPROVED SHOP DRAWINGS, NEW REMODEL OF THE EXISTING 900 S.F.BASEMENT.INCLUDING THE <br /> PRODUCT DATA OR SAMPLES FOR SUCH PORTION OF THE WORK. ¢ <br /> CONSTRUCTION OF NEW INTERIOR WALLS,DOORS,AND TWO WINDOWS WITH <br /> 7.ALL WORK IS TO CONFORM WITH THE CONTRACT DOCUMENTS.DRAWINGS ARE NOT TO BE SCALED FOR INFORMATION IF WINDOW WELLS FOR EACH. w o <br /> UNABLE TO LOCATE DIMENSIONS FOR ANY ITEM OF WORK,CONSULT WITH THE ARCHITECT BEFORE PROCEEDING WITH <br /> CONSTRUCTION. a p <br /> N <br /> 8.IN THE EVENT CERTAIN FEATURES OF THE CONSTRUCTION ARE NOT FULLY SHOWN ON THE CONTRACT DOCUMENTS,THEN a¢ <br /> THEIR CONSTRUCTION SHALL BE OF THE SAME CHARACTER AS FOR SIMILAR CONDITIONS THAT ARE SHOWN OR CALLED FOR a s <br /> AND SHALL BE REVIEWED BY THE ARCHITECT. CODES o a <br /> 9.ALL WORK SHALL BE PERFORMED WITHIN STRICT CONFORMANCE TO THE MINIMUM STANDARDS OF THE CURRENT EDITION w <br /> OF THE INTERNATIONAL BUILDING CODE AND ALL APPLICABLE NATIONAL,STATE,AND LOCAL LAWS,REGULATIONS AND BASED ON THE FOLLOWING CODES: o <br /> ORDINANCES. 20181nternational Building Cade <br /> 2018 lnternational Residential Code <br /> 10.THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE GENERAL SAFETY DURING CONSTRUCTION,AND ALL WORK SHALL 2018 International Mechanical Code '0 <br /> CONFORM TO PERTINENT SAFETY REGULATIONS. 2018 Washington State Energy Code a <br /> 2018 International Fire Code y <br /> 11.THE CONTRACTOR SHALL COORDINATE LOCATIONS OF ANY AND ALL MECHANICAL,TELEPHONE,ELECTRICAL,LIGHTING AND 2018 Uniform Plumbing Code o-F <br /> PLUMBING INCLUDING ALL PIPING,DUCT WORK AND CONDUIT.COORDINATE ALL REQUIRED CLEARANCES FOR INSTALLATION 2020 National Electrical Code w <br /> AND MAINTENANCE OF THE ABOVE EQUIPMENT. 2018 Washington Amendments <br /> 20091CC/ANSI A117.1 a <br /> 12.THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK USING HIS/HER BEST SKILL AND ATTENTION,HE/SHE SHALL BE w <br /> SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS,METHODS,TECHNIQUES,SEQUENCES AND PROCEDURES AND FOR L <br /> COORDINATING ALL PORTIONS OF THE WORK UNDER THE CONTRACT. OCCUPANCY GROUP R-3 r <br /> '0 <br /> 13.THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE ACTS AND OMISSIONS OF HIS/HER EMPLOYEES,SUBCONTRACTORS TOTAL FLOOR AREA 2,820 S.F. <O Z <br /> AND THEIR AGENTS AND EMPLOYEES,AND OTHER PERSONS PERFORMING ANY WORK UNDER A CONTRACT WITH THE CONSTRUCTION TYPE V-B p w <br /> CONTRACTOR. <br /> Q Y <br /> FLOOR AREAS _ <br /> 14.THE CONTRACTOR SHALL PURSUE WORK IN A CONTINUOUS AND DILIGENT MANNER TO INSURE TIMELY COMPLETION OF THE SYMBOL LIST w w <br /> PROJECT. z EXISTING MAIN LEVEL: 1,920 S.F. '^ N <br /> u~i EXISTING BASEMENT: 900 S.F. (J <br /> 15.THE CONTRACTOR AT ALL TIMES SHALL KEEP THE PREMISES FREE FROM ACCUMULATION OF WASTE MATERIALS OR x o < Q <br /> w EXISTING LIVING AREA TOTAL: 2,820 S.F. w'- <br /> RUBBISH �l <br /> CAUSED BY HIS/HER OPERATIONS.AT THE COMPLETION OF THE WORK,HE/SHE SHALL REMOVE ALL HIS/HER WASTE NORTH ARROW ® WOOD FRAMING ASPHALT M <br /> MATERIALS AND RUBBISH FROM AND ABOUT THE PROJECT AS WELL AS ALL HIS/HER TOOLS,CONSTRUCTION EQUIPMENT, NORTH (THROUGH MEMBER) o,i W <br /> MACHINERY,AND SURPLUS MATERIALS. y <br /> WOOD FRAMING ¢ <br /> (INTERRUPTED MEMBER) GATT INSULATION z a M N <br /> 16.THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE LOCATION AND/OR PROTECTION OF ALL EXISTING AND PROPOSED PROPERTY z W w <br /> PIPING,UTILITIES,STRUCTURES,ADJACENT STREETS,AND IMPROVEMENTS DURING THE PERIOD OF CONSTRUCTION. CORNER CEILING HEIGHT BRICK 1 d <br /> 17.UNLESS OTHERWISE PROVIDED IN THE CONTRACT DOCUMENTS,THE CONTRACTOR SHALL PROVIDE AND PAY FOR ALL 0;F'0" SPOT ELEVATION O_On Lu <br /> Lu Y N Q <br /> LABOR,MATERIAL,EQUIPMENT,TOOLS,CONSTRUCTION EQUIPMENT,MACHINERY,WATER,HEAT,UTILITIES,TRANSPORTATION, 12 � <br /> AND OTHER FACILITIES AND SERVICES NECESSARY FOR THE PROPER EXECUTION AND COMPLETION OF THE WORK. J. LEVEL ELEVATION 3� CMU BLOCK rJ <br /> ROOF SLOPE ¢ U <br /> 0'-0" 1/2" ROOF SLOPE PLAN 77, CONCRETE 2 p <br /> 18.WHERE CONFLICTS OCCUR,COORDINATE THE LAYOUT AND EXACT LOCATION OF ALL PARTITIONS,DOORS,TELEPHONES SLOPE LL <br /> AND ELECTRICAL/COMMUNICATION OUTLETS AND SWITCHES WITH ARCHITECT IN THE FIELD BEFORE PROCEEDING WITH r <br /> CONSTRUCTION. BUILDING SECTION 3-12 DOOR SYMBOL - E.I.F.S. J <br /> A9.1 CUT Q (V <br /> 19.WHERE CONFLICT IS ENCOUNTERED BETWEEN THE CONTRACT DOCUMENTS THAT WILL MATERIALLY AFFECT THE QUALITY e _ <br /> WINDOW SYMBOL GRADE I EARTH M c+t <br /> OR EXTENT OF THE WORK,SUCH CONFLICT SHALL BE RESOLVED TO THE SATISFACTION OF THE ARCHITECT BEFORE THE 12 - - - W N <br /> AFFECTED ITEMS AND/OR MATERIALS ARE PURCHASED,FABRICATED AND/OR INSTALLED. <br /> 2 WALL SECTION CUT GRAVEL J <br /> 20.WHERE PRE MANUFACTURED OR PREFABRICATED ITEMS AND/OR MATERIALS ARE TO BE INSTALLED-THE CONTRACTOR A9.1 12 ACCESSORY SYMBOL VICINITY MAP J <br /> SHALL VERIFY ROUGH OR FINISHED DIMENSIONS IN THE FIELD PRIOR TO PURCHASE OR FABRICATION. LL <br /> 72 >>+.: _ GYPSUM BOARD <br /> OpOS <br /> 21.THE CONTRACTOR SHALL GUARANTEE ALL WORK AND MATERIALS TO BE FREE FROM DEFECTS FOR A MINIMUM OF ONE DETAIL CAL-OUT CONTOUR LINE <br /> YEAR FROM DATE OF FINAL ACCEPTANCE,AND PROMPTLY REMEDY SUCH DEFECTS AND ANY SUBSEQUENT DAMAGE CAUSED A9'1 -72- EXISTING GYPSUM SHEATHING PROJECT LOCATION 0 <br /> BY THE DEFECTS OR REPAIR THEREOF,AT NO EXPENSE TO THE OWNER.GUARANTEE PERIODS OF GREATER THAN ONE YEAR '/ CONTOUR LINE LU <br /> F <br /> MAY BE REQUIRED AND CONTAINED WITHIN THE CONTRACT DOCUMENTS. 1 <br /> v ORIENTED STRAND <br /> PROPERTY LINE BOARD '_' EI-Ta <br /> 22.UNLESS OTHERWISE PROVIDED IN THE CONTRACT DOCUMENTS THE CONTRACTOR SHALL SECURE AND PAY FOR THE 2 A9.1 4 ELEVATION BUBBLE 3 m O <br /> BUILDING PERMITAND FOR ALL OTHER PERMITSAND GOVERNMENTAL FEES,LICENSESAND INSPECTIONS NECESSARY FOR THE A PLYWOOD SHEATHING m ; Ler'gua Q 0 MATCH LINELn <br /> PROPER EXECUTION AND COMPLETION OF THE WORK. 7- k_ Riverfront H <br /> 23.WHERE ANY ITEM AND/OR MATERIAL IS INDICATED IN THE CONTRACT DOCUMENTS,AND NOT NECESSARILY DETAILED IN NAME ----- CENTERLINE RIGID INSULATION "t-, Park W <br /> EACH SPECIFIC CASE,BUT IS REQUIRED FOR A COMPLETE AND PROFESSIONAL INSTALLATION-SUCH ITEM AND/OR MATERIAL <br /> SHALL BE PROVIDED AS IF SHOWN AND DETAILED IN FULL.PROVIDE MEANS TO FURNISH AND INSTALL. ROOM NAME& 0 Z <br /> NUMBER - '_ SAND/MORTAR/ w r <br /> PH�H PHONE LINE O z <br /> '.;5 T,�:-"7" PLASTER U $ ¢ w <br /> REVISION CLOUD& G G GAS LINE 7�%%i7T%%////// STEEL m p r=ii <br /> NUMBER 7777T N <br /> CHANGE IN FLOOR STONE ELECTRICAL LINE 15rn a L N TIL' EICARP►T MATERIAL E E m W <br /> TXX FENCE LINE 9L1-INll-LWWILLILLL-L1L TECTUM T y v, O <br /> l U Q <br /> h p <br /> SSSS SANITARYSEWER ® WOOD FINISH N G o <br /> + GRID LINES N TV TELEVISION LINE 0 2326 MCDoUga Avenue o 0 N <br /> GLASS 2III <br /> W W WATERLINE RIVERSIDE ^ 2 N O <br /> LL U Q <br /> 04 <br />