|
E:2)/\ L-FH I S R E S I D E N C E - 272 E3
<br /> J
<br /> mm
<br /> Q
<br /> REMODEL/ADDITION
<br /> BAD NT W W�
<br /> Lw Wat
<br /> w L r NNN
<br /> IL
<br /> r H N N
<br /> w H
<br /> Uw Uwa
<br /> maN
<br /> Om W;1
<br /> GENERAL NOTES SHEET INDEX PROJECT TEAM U a San
<br /> OWNER Z NON
<br /> <_ =
<br /> ARCHITECTURAL BALTHIS JOSHUA L&JENNIFER A r w �N
<br /> Un N G m
<br /> 1.THESE GENERAL NOTES PERTAIN TO WORK DESCRIBED ON ALL CONTRACT DOCUMENTS. N h
<br /> 2326 MCDOUGALL AVE. p a f N
<br /> 2.THE CONTRACT DOCUMENTS CONSIST OF THE OWNER CONTRACTOR AGREEMENT,THE CONDITIONS OF CONTRACT A0.1 TITLE SHEET EVERETT,WA 98201 f' N V
<br /> (GENERAL,SUPPLEMENTARY,AND OTHER CONDITIONS),THE DRAWINGS,THE SPECIFICATIONS,AND ALL ADDENDA ISSUED A1.1 SITE PLAN a y U N 0 Q
<br /> PRIOR TO AND ALL MODIFICATIONS ISSUED AFTER EXECUTION OF THE CONTRACT. A2.1 FLOOR PLAN ARCHITECTURAL
<br /> 3.CONCEPT ARCHITECTURE,LLC IS THE AUTHOR OF THESE PLANS AND CLAIMS A COPYRIGHT IN THESE PLANS AND THE CONCEPT ARCHITECTURE,LLC. P:(425)377-8786 PROPERTY INFORMATION of
<br /> DESIGNS CONTAINED IN THESE PLANS.THIS CLAIM IS MADE UNDER TITLE 17 OF THE UNITED STATES CODE AND ALL APPLICABLE 2911 1/2 HEWITT AVE,SUITE 2, a O
<br /> TREATIES AND FOREIGN LAWS.THESE COPYRIGHTED DRAWING FILES ARE TO BE USED FOR REFERENCE ONLY.CONCEPT EVERETT,WA 98201 MREIMERS@CONCEPTARCHITECTURE.COM .W
<br /> ARCHITECTURE,LLC WILL TAKE NO RESPONSIBILITY FOR ANY CHANGES MADE TO THESE DOCUMENTS BY ANOTHER PARTY AND .0
<br /> WA 98201 EVERETT, i 3
<br /> NO LICENSE IS GIVEN FOR TRANSFER OF THESE COPYRIGHTS TO ANOTHER PARTY. ADDRESS 2326 MCDOUGALL AVE. r N
<br /> 4.THE WORK COMPRISES THE COMPLETED CONSTRUCTION REQUIRED BY THE CONTRACT DOCUMENTS AND INCLUDES ALL APN 00439149501900 o z
<br /> LABOR NECESSARY TO PRODUCE SUCH CONSTRUCTION,AND ALL MATERIALS AND EQUIPMENT INCORPORATED OR TO BE SIZE 0.21 ACRES
<br /> INCORPORATED IN SUCH CONSTRUCTION.
<br /> SUBDIVISION X Q w
<br /> 5.SHOP DRAWINGS,PRODUCT DATA AND SAMPLES ARE NOT A PART OF THE CONTRACT DOCUMENTS.THE ARCHITECT WILL w w
<br /> REVIEW THEM,BUT ONLY FOR CONFORMANCE WITH THE DESIGN CONCEPT OF THE WORK AND WITH THE INFORMATION GIVEN ZONE R-2 rn s
<br /> IN THE CONTRACT DOCUMENTS.THE CONTRACTOR SHALL NOT BE RELIEVED OF RESPONSIBILITY FOR ANY DEVIATION FROM
<br /> STHE AMPLESUIREMENTSOFTHECONTRACTDOCUMENTSBYTHEARCHITECTSREVIEWOFSHOPDRAWINGS,PRODUCTDATAOR PROJECT DESCRIPTION =�
<br /> Y F
<br /> 6.THE CONTRACTOR SHALL CAREFULLY STUDY AND COMPARE THE CONTRACT DOCUMENTS AND SHALL AT ONCE REPORT TO O o
<br /> THE ARCHITECT ANY ERROR,INCONSISTENCY OR OMISSIONS HE MAY DISCOVER.THE CONTRACTOR SHALL PERFORM NO ¢
<br /> PORTION OF THE WORK AT ANY TIME WITHOUT CONTRACT DOCUMENTS OR,WHERE REQUIRED,APPROVED SHOP DRAWINGS, NEW REMODEL OF THE EXISTING 900 S.F.BASEMENT.INCLUDING THE
<br /> PRODUCT DATA OR SAMPLES FOR SUCH PORTION OF THE WORK. ¢
<br /> CONSTRUCTION OF NEW INTERIOR WALLS,DOORS,AND TWO WINDOWS WITH
<br /> 7.ALL WORK IS TO CONFORM WITH THE CONTRACT DOCUMENTS.DRAWINGS ARE NOT TO BE SCALED FOR INFORMATION IF WINDOW WELLS FOR EACH. w o
<br /> UNABLE TO LOCATE DIMENSIONS FOR ANY ITEM OF WORK,CONSULT WITH THE ARCHITECT BEFORE PROCEEDING WITH
<br /> CONSTRUCTION. a p
<br /> N
<br /> 8.IN THE EVENT CERTAIN FEATURES OF THE CONSTRUCTION ARE NOT FULLY SHOWN ON THE CONTRACT DOCUMENTS,THEN a¢
<br /> THEIR CONSTRUCTION SHALL BE OF THE SAME CHARACTER AS FOR SIMILAR CONDITIONS THAT ARE SHOWN OR CALLED FOR a s
<br /> AND SHALL BE REVIEWED BY THE ARCHITECT. CODES o a
<br /> 9.ALL WORK SHALL BE PERFORMED WITHIN STRICT CONFORMANCE TO THE MINIMUM STANDARDS OF THE CURRENT EDITION w
<br /> OF THE INTERNATIONAL BUILDING CODE AND ALL APPLICABLE NATIONAL,STATE,AND LOCAL LAWS,REGULATIONS AND BASED ON THE FOLLOWING CODES: o
<br /> ORDINANCES. 20181nternational Building Cade
<br /> 2018 lnternational Residential Code
<br /> 10.THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE GENERAL SAFETY DURING CONSTRUCTION,AND ALL WORK SHALL 2018 International Mechanical Code '0
<br /> CONFORM TO PERTINENT SAFETY REGULATIONS. 2018 Washington State Energy Code a
<br /> 2018 International Fire Code y
<br /> 11.THE CONTRACTOR SHALL COORDINATE LOCATIONS OF ANY AND ALL MECHANICAL,TELEPHONE,ELECTRICAL,LIGHTING AND 2018 Uniform Plumbing Code o-F
<br /> PLUMBING INCLUDING ALL PIPING,DUCT WORK AND CONDUIT.COORDINATE ALL REQUIRED CLEARANCES FOR INSTALLATION 2020 National Electrical Code w
<br /> AND MAINTENANCE OF THE ABOVE EQUIPMENT. 2018 Washington Amendments
<br /> 20091CC/ANSI A117.1 a
<br /> 12.THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK USING HIS/HER BEST SKILL AND ATTENTION,HE/SHE SHALL BE w
<br /> SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS,METHODS,TECHNIQUES,SEQUENCES AND PROCEDURES AND FOR L
<br /> COORDINATING ALL PORTIONS OF THE WORK UNDER THE CONTRACT. OCCUPANCY GROUP R-3 r
<br /> '0
<br /> 13.THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE ACTS AND OMISSIONS OF HIS/HER EMPLOYEES,SUBCONTRACTORS TOTAL FLOOR AREA 2,820 S.F. <O Z
<br /> AND THEIR AGENTS AND EMPLOYEES,AND OTHER PERSONS PERFORMING ANY WORK UNDER A CONTRACT WITH THE CONSTRUCTION TYPE V-B p w
<br /> CONTRACTOR.
<br /> Q Y
<br /> FLOOR AREAS _
<br /> 14.THE CONTRACTOR SHALL PURSUE WORK IN A CONTINUOUS AND DILIGENT MANNER TO INSURE TIMELY COMPLETION OF THE SYMBOL LIST w w
<br /> PROJECT. z EXISTING MAIN LEVEL: 1,920 S.F. '^ N
<br /> u~i EXISTING BASEMENT: 900 S.F. (J
<br /> 15.THE CONTRACTOR AT ALL TIMES SHALL KEEP THE PREMISES FREE FROM ACCUMULATION OF WASTE MATERIALS OR x o < Q
<br /> w EXISTING LIVING AREA TOTAL: 2,820 S.F. w'-
<br /> RUBBISH �l
<br /> CAUSED BY HIS/HER OPERATIONS.AT THE COMPLETION OF THE WORK,HE/SHE SHALL REMOVE ALL HIS/HER WASTE NORTH ARROW ® WOOD FRAMING ASPHALT M
<br /> MATERIALS AND RUBBISH FROM AND ABOUT THE PROJECT AS WELL AS ALL HIS/HER TOOLS,CONSTRUCTION EQUIPMENT, NORTH (THROUGH MEMBER) o,i W
<br /> MACHINERY,AND SURPLUS MATERIALS. y
<br /> WOOD FRAMING ¢
<br /> (INTERRUPTED MEMBER) GATT INSULATION z a M N
<br /> 16.THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE LOCATION AND/OR PROTECTION OF ALL EXISTING AND PROPOSED PROPERTY z W w
<br /> PIPING,UTILITIES,STRUCTURES,ADJACENT STREETS,AND IMPROVEMENTS DURING THE PERIOD OF CONSTRUCTION. CORNER CEILING HEIGHT BRICK 1 d
<br /> 17.UNLESS OTHERWISE PROVIDED IN THE CONTRACT DOCUMENTS,THE CONTRACTOR SHALL PROVIDE AND PAY FOR ALL 0;F'0" SPOT ELEVATION O_On Lu
<br /> Lu Y N Q
<br /> LABOR,MATERIAL,EQUIPMENT,TOOLS,CONSTRUCTION EQUIPMENT,MACHINERY,WATER,HEAT,UTILITIES,TRANSPORTATION, 12 �
<br /> AND OTHER FACILITIES AND SERVICES NECESSARY FOR THE PROPER EXECUTION AND COMPLETION OF THE WORK. J. LEVEL ELEVATION 3� CMU BLOCK rJ
<br /> ROOF SLOPE ¢ U
<br /> 0'-0" 1/2" ROOF SLOPE PLAN 77, CONCRETE 2 p
<br /> 18.WHERE CONFLICTS OCCUR,COORDINATE THE LAYOUT AND EXACT LOCATION OF ALL PARTITIONS,DOORS,TELEPHONES SLOPE LL
<br /> AND ELECTRICAL/COMMUNICATION OUTLETS AND SWITCHES WITH ARCHITECT IN THE FIELD BEFORE PROCEEDING WITH r
<br /> CONSTRUCTION. BUILDING SECTION 3-12 DOOR SYMBOL - E.I.F.S. J
<br /> A9.1 CUT Q (V
<br /> 19.WHERE CONFLICT IS ENCOUNTERED BETWEEN THE CONTRACT DOCUMENTS THAT WILL MATERIALLY AFFECT THE QUALITY e _
<br /> WINDOW SYMBOL GRADE I EARTH M c+t
<br /> OR EXTENT OF THE WORK,SUCH CONFLICT SHALL BE RESOLVED TO THE SATISFACTION OF THE ARCHITECT BEFORE THE 12 - - - W N
<br /> AFFECTED ITEMS AND/OR MATERIALS ARE PURCHASED,FABRICATED AND/OR INSTALLED.
<br /> 2 WALL SECTION CUT GRAVEL J
<br /> 20.WHERE PRE MANUFACTURED OR PREFABRICATED ITEMS AND/OR MATERIALS ARE TO BE INSTALLED-THE CONTRACTOR A9.1 12 ACCESSORY SYMBOL VICINITY MAP J
<br /> SHALL VERIFY ROUGH OR FINISHED DIMENSIONS IN THE FIELD PRIOR TO PURCHASE OR FABRICATION. LL
<br /> 72 >>+.: _ GYPSUM BOARD
<br /> OpOS
<br /> 21.THE CONTRACTOR SHALL GUARANTEE ALL WORK AND MATERIALS TO BE FREE FROM DEFECTS FOR A MINIMUM OF ONE DETAIL CAL-OUT CONTOUR LINE
<br /> YEAR FROM DATE OF FINAL ACCEPTANCE,AND PROMPTLY REMEDY SUCH DEFECTS AND ANY SUBSEQUENT DAMAGE CAUSED A9'1 -72- EXISTING GYPSUM SHEATHING PROJECT LOCATION 0
<br /> BY THE DEFECTS OR REPAIR THEREOF,AT NO EXPENSE TO THE OWNER.GUARANTEE PERIODS OF GREATER THAN ONE YEAR '/ CONTOUR LINE LU
<br /> F
<br /> MAY BE REQUIRED AND CONTAINED WITHIN THE CONTRACT DOCUMENTS. 1
<br /> v ORIENTED STRAND
<br /> PROPERTY LINE BOARD '_' EI-Ta
<br /> 22.UNLESS OTHERWISE PROVIDED IN THE CONTRACT DOCUMENTS THE CONTRACTOR SHALL SECURE AND PAY FOR THE 2 A9.1 4 ELEVATION BUBBLE 3 m O
<br /> BUILDING PERMITAND FOR ALL OTHER PERMITSAND GOVERNMENTAL FEES,LICENSESAND INSPECTIONS NECESSARY FOR THE A PLYWOOD SHEATHING m ; Ler'gua Q 0 MATCH LINELn
<br /> PROPER EXECUTION AND COMPLETION OF THE WORK. 7- k_ Riverfront H
<br /> 23.WHERE ANY ITEM AND/OR MATERIAL IS INDICATED IN THE CONTRACT DOCUMENTS,AND NOT NECESSARILY DETAILED IN NAME ----- CENTERLINE RIGID INSULATION "t-, Park W
<br /> EACH SPECIFIC CASE,BUT IS REQUIRED FOR A COMPLETE AND PROFESSIONAL INSTALLATION-SUCH ITEM AND/OR MATERIAL
<br /> SHALL BE PROVIDED AS IF SHOWN AND DETAILED IN FULL.PROVIDE MEANS TO FURNISH AND INSTALL. ROOM NAME& 0 Z
<br /> NUMBER - '_ SAND/MORTAR/ w r
<br /> PH�H PHONE LINE O z
<br /> '.;5 T,�:-"7" PLASTER U $ ¢ w
<br /> REVISION CLOUD& G G GAS LINE 7�%%i7T%%////// STEEL m p r=ii
<br /> NUMBER 7777T N
<br /> CHANGE IN FLOOR STONE ELECTRICAL LINE 15rn a L N TIL' EICARP►T MATERIAL E E m W
<br /> TXX FENCE LINE 9L1-INll-LWWILLILLL-L1L TECTUM T y v, O
<br /> l U Q
<br /> h p
<br /> SSSS SANITARYSEWER ® WOOD FINISH N G o
<br /> + GRID LINES N TV TELEVISION LINE 0 2326 MCDoUga Avenue o 0 N
<br /> GLASS 2III
<br /> W W WATERLINE RIVERSIDE ^ 2 N O
<br /> LL U Q
<br /> 04
<br />
|