Laserfiche WebLink
Seismic Load Calculation for Components and System Wind Pressure= 32.8 psf(LRFD) <br /> (Reference: 2018 IBC Section 1613&ASCE 7-16 Section 13.3) <br /> EXISTING <br /> Sector Quantity Model Model Height Width Depth Weight Tot.Weight Area Wind Force <br /> (in) (in) (in) (Ibs) (Ibs) (ft2) (Ibs) <br /> 1 Comscope FFV4-65B-R3-VI 71.97 25.20 9.25 108.0 108.00 12.59 412.7 <br /> 1 Nokia AEHC 38.20 21.50 5.90 108.0 108.00 5.70 186.9 <br /> 1 Nokia AHLOA 22.051 12.13 7.44 83.81 83.78 1.86 60.9 <br /> 1 Alpha Nokia AHFIG 27.40 12.10 6.50 70.5 70.50 2.30 75.4 <br /> 0.00 0.00 <br /> 0.00 0.00 <br /> 0.00 0.00 <br /> 0.00 0.00 <br /> Total 1 370.28 22.461 735.83 <br /> 1 Comscope FFV4-65B-R3-VI 71.97 25.20 9.25 108.0 108.00 12.59 412.7 <br /> 1 Nokia AEHC 38.20 21.50 5.90 108.0 108.00 5.70 186.9 <br /> 1 Nokia AHLOA 22.05 12.13 7.44 83.8 83.78 1.86 60.9 <br /> 1 Beta Nokia AHFIG 27.40 12.10 6.50 70.5 70.50 2.30 75.4 <br /> 0.00 0.00 <br /> 0.00 0.00 <br /> 0.00 0.00 <br /> 0.00 0.00 <br /> Total 370.28 22.46 735.83 <br /> 1 Comscope FFV4-65B-R3-VI 71.97 25.20 9.25 108.0 108.00 12.59 412.7 <br /> 1 Nokia AEHC 38.20 21.50 5.90 108.0 108.00 5.70 186.9 <br /> 1 Nokia AHLOA 22.05 12.13 7.44 83.8 83.78 1.86 60.9 <br /> 1 Gamma Nokia AHFIG 27.40 12.10 6.50 70.5 70.50 2.30 75.4 <br /> 0.00 0.00 <br /> 0.00 0.00 <br /> 0.00 0.00 <br /> 0.00 0.00 <br /> Total 370.28 22.46 735.83 <br /> Total All Sectors 1110.84 67.37 2207.48 <br /> NOTE: NO CHANGE TO LOADS, GAMMA SECTOR TO BE RELOCATED TO PARAPET <br /> LOADS ON EA. ANTENNA PIPE MOUNT ARE CONSERVATIVE (500# DL AND 41.5psf WIND LOAD <br /> W/A TRIBUTARY OF 2.5' WIDE FOR THE FULL LENGTH OF THE PIPE MAST (25sf)) <br /> Description By Date <br /> MRD 11/22/2024 <br /> CChecked Date <br /> EN lV -C= <br /> Wind Load for Antenna Supporting Structures <br /> Project Scale Sheet No. <br /> SE01510A Downtown Everett-Wall N.T.S. <br /> 250 4th Ave.South <br /> Suite 200 Job No. <br /> Edmonds,WA 98020 24088.614 13 <br />