Laserfiche WebLink
REFERENCE <br /> DOCUMENT <br /> GENERALNOTES <br /> A. MAINTAIN'/."PER FOOT MINIMUM SLOPE THROUGHOUT ROOF. <br /> B. WALKWAY PADS ARE SHOWN SCHEMATICALLY.WALKWAY PADS SHOULD BE PROVIDED AT AREAS <br /> SHOWN AND TO INCLUDE ALL EQUIPMENT INSTALLATIONS,DOORWAYS,STAIR/LADDER LANDINGS, M <br /> ■ <br /> AND OTHER AREAS REQUIRING REGULAR MAINTENANCE. <br /> C. CONTRACTOR TO PROVIDE COVERS,ENCLOSURES,AND/OR SEALANTS AT ALL ROOF <br /> PENETRATIONS,PIPES,CURBS,DUCTS,AND CONNECTIONS.COORDINATE AND REFER TO <br /> A B C D F G H MECHANICAL/ELECTRICAL DISCIPLINES FOR ADDITIONAL INFORMATION. Architecture Interiors <br /> D. PROVIDE SPLASH13LOCKS AT DOWNSPOUTS OF ALL ROOF ACCESSORY STRUCTURES. Planning Engineering <br /> E. SIZE AND LOCATION OF MECHANICAL PENTHOUSE SHOWN SCHEMATICALLY.VERIFY ALL INTERIOR <br /> WALLS,ELECTRICAL AND MECHANICAL UNITS IN FIELD. <br /> 12'-0" 12'-P' 10'-7" 5'-11 1f2" F. PROVIDE CONCRETE SEALANT ON INSIDE FACE OF PARAPET WALLS AND TOP OF PARAPET. <br /> G. ADJUST DOWNSPOUTS OR PROVIDE NEW AS NEEDED FOR NEW ROOF HEIGHT. <br /> H. CONTRACTOR TO COORDINATE THE ROOFING INSTALLATION WITH DECOMMISSIONING OF <br /> COOLING TOWERAND INSTALLATION OF NEW COOLING TOWER.REFER TO MECHANICAL PLANS. <br /> -6" 6'-0" 11 24 I. IF THERE IS A CONFLICT WITH INSTALLING THE INSULATION TO THE HEIGHT INDICATED ON PLANS, Portland,OR <br /> 81/4"AFF a CONTRACTOR TO NOTIFY ARCHITECT FOR COORDINATION WITH AUTHORITY HAVING JURISDICTION. 503.224.9560 <br /> - INSULATION a OS J. REFER TO MECHANICAL PLANS FOR EQUIPMENT COORDINATION. <br /> @ CURB K. PROVIDE GUARDRAILS WHERE EQUIPMENT IS LESS THAN 10'-0"FROM EDGE OF ROOF. Vancouver,WA <br /> L. REFER TO M1.31&M1.32 FOR ADDITIONAL PHASING OF DEMOLITION TO SUPPORT INSTALLATION OF 360.695.7879 <br /> NEW ROOFTOPMECHANICAL SYSTEMS. Seattle,WA <br /> V — — — — — — — — — — — — — — — — " — — M. GC TO COORDINATE ALL EXISTING DOOR THRESHOLDS/DOOR OPENINGS,ELEVATED ROOFTOP 206.749 Seattle, <br /> ,WA <br /> y EQUIPMENT TO REMAIN WITH NEW ROOFING THICKNESS.PROVIDE CRICKETS AND MODIFY <br /> HP SLOPES AS REQUIRED TO PROVIDE POSITIVE DRAINAGE AWAY FROM ROOFTOP PERIMETER AND www.mcknze.com <br /> 17 wa 11-24 EXISTING MECHANICAL PENTHOUSE. COORDINATION,CRICKET DRAWINGS,ETC.MUST BE <br /> COMPLETED UPON AWARD. ww A�I/C I C" <br /> rn m 5 TYP. _ 1_1 `G G <br /> cc <br /> 8'-p" A5.12 <br /> ACCD 3-04005 3-04 1 3'-0' <br /> 013 S5.52 Client <br /> ORD 05-06F RD D City of Everett <br /> 7 3/4"AFF <br /> INSULATION — <br /> CCD \ 1 f °t— @CURB <br /> 5 015 <br /> - — — 1/4" �I OS-03 I' OCCD t I LEGEND <br /> 113/8"AFF SLOPE 'O` _ _ __J 015 , , EVERETT <br /> '-o" 05-03 CCD CCD <br /> INSULATION 5 4 — WASHINGTON <br /> 1r 1-3-— AREA OF NEW ROOFING ASSEMBLY WITH VAPOR BARRIER,TAPERED R-38 <br /> WEST SIDE OF \ 4 <br /> PLATFORM 00-29 INSULATION AND 3-PLY MODIFIED BITUMEN ROOFING <br /> COLUMNS 9 CCD 4 5/8"AFF 11/4" A5.12 Project <br /> 1'-23/4"AFF - 55.52 Vµ\013 IN SOUTH SIDE COMPRESSOR SLOPE <br /> Everett Municipal <br /> CURB @ DN OF PLATFORM NEW WALKWAY PADS Building Tenant <br /> INSULATION ° ROOM g <br /> CURB 1102 A012 Improvement <br /> o1z <br /> D ORD iv o EXISTING WALL TO REMAIN <br /> 2930 WETMORE AVE <br /> w I I ELEVATOR o EVERETT,WA 98201 <br /> 4 — — — — — I T — —MACHINE — — — — T — NEW WALL <br /> CCD <br /> - _ _ <br /> 4 013 00-29 ROOM HP w <br /> 7 7/8"AFF 1101 EXISTING DOOR TO REMAIN <br /> INSULATION @ 3/8"SLOPE <br /> WEST SIDE OF HP 14-08 Ii <br /> PLATFORM 3/8"S OPE VESTIBULE w ORD NEW ROOF DRAIN-PENETRATIONS TO REMAIN,DRAIN COVER TO BE REPLACED noa9 <br /> COLUMNS 05-08 f 1103 REGISTERED <br /> 107/8"AFF 5 022 ARCHITECT <br /> INSULATION @ 5 SLOPE ODS EXISTING DOWNSPOUT <br /> WEST 55.51 ^---------- <br /> LATFO M MIXING O"A HANSON <br /> PLATFORM 05-0 <br /> COLUMNS i PLENUM 1� ;I HP HIGHEST POINT OF ROOF PITCH SHINGTON <br /> 1106 \ / -———- EXTENTS OF MECHANICAL CCD <br /> — — FAN — — EQUIPMENTABOVEREFERENCE �011 <br /> 6'-71/2" 8'-71/2" ROOM MEP DRAWINGS <br /> 1104 © MACKENZIE <br /> CCD 2024 ALL RIGHTS RESERVED <br /> I TYP CCD WINDOW WASHING SAFETY 3 THESEDRAWINGS ARE THE PROPERTY OF <br /> a OS 09 ANCHOR,SEE WA5.12 FOR MORE 012 MACKENZIE AND ARE NOT TO BE USED <br /> I 10 012 INFORMATION OR REPRODUCED IN ANY MANNER, <br /> PROPOSED <br /> RETURN A5.1 WITHOUT PRIOR WRITTEN PERMISSION <br /> MECHANICAL I 114" AIR <br /> UNIT I I SLOPE PLENUM REVISION SCHEDULE <br /> I 1105 4"AFF TYP. iA' Delta Issued As Issue Date <br /> INSULATION@ SLOP 1 CCD 005 04.05.2024 <br /> — OS-03 I PENTHOUSE WALL o Ii 2 CCD 011 05.06.2024 <br /> 3 CCD 012 05.13.2024 <br /> — _ - a __ ___ —— — w�tl 4 CCD 013 05.17.2024 <br /> e =Or R ORD 5 CCD 015 06.19.2024 <br /> KEYNOTES 6 CCD 022 08.30.2024 <br /> i —————————— —— —_—_—--1 3,_p�� �---------� ——— 2304 CCD <br /> ORD TYp ".-Yr-,--Y,.-Yr-WITH,--Y,rAST--ARAPET-Y g <br /> 11-24 L———— ———— ————— — a a � 00-29 ALIGN W ITH PRECAST PARAPET JOINT 022 <br /> O O 03 D S C U E F M C I A UNIT.SEE STRUCTURAL DRAWINGS FOR <br /> u w MORE INFORMATION.VERIFY LOCATION ON PLAN W/MEP.PROVIDE BOOT <br /> - FLASHING AT EACH HSS COLUMN <br /> 05-06 STL STRAP CTR OVER COL W/POST-INSTALLED ANCHORS PER 5/55.52 SHEET TITLE: <br /> 1'- 05-07 REINSTALL EXISTING LADDER ON SLEEPER BASE.SIM DETAIL 8/A5.12 3 CCD ROOF PLAN <br /> _ HP 6" 05-08 REINSTALL EXISTING STAIR ON SLEEPER BASE.SEE DETAIL 9/A5.12 012 <br /> 05-09 SET OF(2)PROBEL PB48S-B4S SAFETY ANCHORS AT 2'-0"O.C.EACH SET TO BE <br /> SPACED AT 10'O.C.UNO.CENTERED ON PRECAST PARAPET PANEL UNO.SEE CCD <br /> 3/A5.12 FOR MORE INFORMATION 011 <br /> w 11-24 PROPOSED SATELLITE LOCATION PER OTHERS UNDER SEPARATE PERMIT <br /> O11-25 PROPOSED BRANDING ENCLOSURE LOCATION PER OTHERS UNDER SEPARATE <br /> 6'-0" 6" PERMIT <br /> 1 1 I CCD 1-s P P S F T T 5 CCD <br /> 5'-111/2" 10'-7" 11-25 �011 11-27 T-MOBILE EQUIPMENT AND SLEEPERS BY OTHERS 022 <br /> 4- O L A Q ACTURER <br /> 8 1/8"AFF 6 1/2"AFF 23-04 LOCATION OF NEW ROOFTOP MECHANICAL EQUIPMENT,REFER TO HVAC <br /> INSULATION @ INSULATION @ <br /> DRAWINGS FOR ADDITIONAL INFORMATION <br /> CURB SOUTH SIDE OF 1 <br /> PLATFORM <br /> COLUMNS <br /> SHEET <br /> 1 ROOF PLAN A2.01 <br /> 01 <br /> JOB NO.22OO2395OO <br /> PERMIT SET 11.06.2023 <br /> Aut,d,,k Doc,://Ew,n Municipal Builtling TI1235�ERETTMUNICIPAL.B.M 8/291202411:48:02AM 118"=1'-0" <br />