GENERAL NOTES <br />ALL DESIGN AND CONSTRUCTION SHALL CONFORM TO THE REQUIREMENTS OF THE INTERNATIONAL BUILDING CODE 2018 <br />EDITION. <br />CONTRACTOR SHALL VERIFY ALL LEVELS, DIMENSIONS AND EXISTING CONDITIONS IN FIELD BEFORE PROCEEDING WITH ANY <br />CONSTRUCTION OR DEMOLITION. CONTRACTOR SHALL NOTIFY THE ARCHITECT OF ANY DISCREPANCIES OR FIELD CHANGES. <br />CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND THE METHODS, TECHNIQUES, SEQUENCES OR <br />PROCEDURES REQUIRED TO PERFORM THE WORK. <br />CONTRACTOR SHALL PROVIDE ADEQUATE SHORING AN <br />D ND BRACING OF ALL STRUCTURAL MEMBERS, EXISTING CONSTRUCTION <br />AND SOIL EXCAVATIONS AS REQUIRED, IN A MANNER SUITABLE TO THE WORK SEQUENCE. TEMPORARY SHORING AND <br />BRACING SHALL NOT BE REMOVED UNTIL ALL FINAL CONNECTIONS HAVE BEEN COMPLETED IN ACCORDANCE WITH THE <br />DRAWINGS AND MATERIALS HAVE ACHIEVED DESIGN STRENGTH. FOUNDATIONS WALLS GREATER THAN 4 FEET SHALL NOT <br />BE BACKFILLED UNTIL THE FLOOR FRAMING AND ALL CONNECTIONS TO THE FLOOR FRAMING PER THESE DETAILS ARE <br />COMPLETE. <br />CHANGES: NO CHANGES TO THESE STRUCTURAL DRAWINGS ARE PERMITTED WITHOUT WRITTEN CONSENT OF THE <br />ENGINEER. CHANGES WILL BE BILLED TO THE CLIENT, OWNER OR CONTRACTOR AT THE ENGINEER'S HOURLY RATE. <br />SUBMITTALS: SHOP DRAWINGS SHALL BE SUBMITTED TO THE ARCHITECT PRIOR TO ANY FABRICATION OR CONSTRUCTION <br />FOR ALL THE FOLLOWING: STRUCTURAL STEEL, STEEL CANOPIES, GLUED -LAMINATED MEMBERS AND PRE -MANUFACTURED <br />WOOD MEMBERS. <br />DESIGN DRAWINGS AND CALCULATIONS, FOR PRE -MANUFACTURED WOOD TRUSSES AND JOISTS SHALL BEAR THE SEAL <br />AND SIGNATURE OF THE WASHINGTON STATE REGISTERED PROFESSIONAL ENGINEER WHO IS RESPONSIBLE FOR THE <br />DESIGN, AND SHALL BE SUBMITTED TO THE ARCHITECT AND BUILDING OFFICIAL FOR REVIEW PRIOR TO FABRICATION. <br />DESIGN LOADS <br />LIVE LOADS: LIVE LOADS ARE DETERMINED IN ACCORDANCE WITH ASCE CH. 7 <br />L = 40 PSF (RESIDENTIAL) <br />SNOW LOADS: SNOW LOADS ARE DETERMINED IN ACCORDANCE WITH ASCE CH. 7 WITH THE FOLLOWING FACTORS: <br />GROUND SNOW LOAD PG = 25 PSF CT = 1.0 CE = 1.0 <br />ROOF SNOW LOAD PS = 25 PSF IS = 1.0 <br />WIND LOADS: WIND LOADS ARE BASED ON ASCE 7-16 CH. 28 (ENVELOPE PROCEDURE) WITH THE FOLLOWING FACTORS: <br />EXPOSURE CATEGORY = B IW = 1.0 <br />VELOCITY (3 SEC) = 110 MPH (ULT) KZT = 1.38 <br />DESIGN WIND PRESSURED FOR DETERMINING FORCES ON COMPONENTS AND CLADDING ARE DETERMINED IN <br />ACCORDANCE WITH ASCE 7-16 CHAPTER 30. <br />SEISMIC LOADS: SEISMIC LOADS ARE BASED ON THE EQUIVALENT LATERAL FORCE PROCEDURE IN ASCE 7-16 SECTION <br />12.8 WITH THE FOLLOWING FACTORS: <br />RISK CATEGORY = II SS = 1.265 <br />SITE CLASS = D S1 = 0.448 <br />DESIGN CATEGORY = D SOS = 1.C12 <br />R = 6.5 (WOOD SHEAR WALL) CS = 0.156 (ULT.) <br />R = 1.5 (WOOD FRAME) CS = 0.675 (ULT.) <br />IE = 1.0 <br />FOUNDATIONS <br />CONCRETE FOUNDATIONS SHALL BEAR ON STIFF, COMPETENT, UNDISTURBED NATIVE SOIL PRIOR TO CONSTRUCTION, THE <br />CONTRACTOR SHALL OBTAIN CONFIRMATION FROM THE BUILDING OFFICIAL THAT THE NATIVE SOIL AT THIS PROJECT IS <br />ADEQUATE TO SUPPORT THE FOLLOWING BEARING PRESSURE: ALLOWABLE BEARING PRESSURE USED FOR STRUCTURAL <br />DESIGN = 1500 PSF. <br />WHERE FOOTINGS MUST BEAR ON STRUCTURAL FILL DUE TO INADEQUATE SOIL CONDITIONS, THE FILL SHALL BE MIXED <br />AND COMPACTED IN ACCORDANCE WITH SPECIFICATIONS PROVIDED BY A GEOTECHNICAL ENGINEER LICENSED IN THE <br />STATE OF WASHINGTON. <br />BOTTOM OF FOOTING ELEVATION SHALL BE LOCATED AT MINIMUM FROST DEPTH 18" BELOW TOP OF FINISHED GRADE <br />UNLESS REQUIRED OTHERWISE BY THE BUILDING OFFICIAL. THE CONTRACTOR SHALL CONFIRM THE MINIMUM FROST DEPTH <br />WITH THE BUILDING OFFICIAL PRIOR TO EXCAVATION. <br />CONCRETE <br />CONCRETE WORK SHALL COMPLY, IN GENERAL, WITH ACI 301 (LATEST EDITION) "SPECIFICATIONS FOR STRUCTURAL <br />CONCRETE FOR BUILDINGS. <br />CONCRETE MIXES: CONCRETE MIXES SHALL CONFORM ACI 318 CH. 5. MINIMUM CONCRETE STRENGTH F'C AT 28 DAYS <br />SHALL BE AS FOLLOWS: <br />SLAB -ON -GRADE, CURBS AND PADS - 2500 PSI <br />FOOTINGS - 3000 PSI <br />WALLS, STEMS - 3000 PSI <br />WATER/CEMENT RATIO SHALL BE MEASURED BY WEIGHT AND SHALL BE BASED ON THE TOTAL CEMENTITIOUS MATERIAL. <br />WATER/CEMENT RATIO SHALL BE DETERMINED BY THE SUPPLIER BASED ON STRENGTH REQUIREMENTS AND SHALL NOT <br />EXCEED 0.55. WATER -REDUCING ADMIXTURES MAY BE INCORPORATED IN CONCRETE MIX DESIGNS, BUT SHALL CONFORM <br />TO ASTM C 464 AND BE USED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. CACL AND OTHER <br />WATER-SOLUBLE CHLORIDE ADMIXTURES SHALL NOT BE USED. <br />REINFORCING STEEL: ALL REINFORCING SHALL BE DEFORMED BAR (REBAR) WITH BAR DIAMETERS SPECIFIED IN THESE <br />DRAWINGS AND PROPERTIES BELOW: <br />ALL REINFORCING UNLESS NOTED OTHERWISE - ASTM A615, GRADE 60 <br />#3 STIRRUPS AND TIES - ASTM A615, GRADE 40 <br />WELDED REBAR - ASTM A706, GRADE 60 <br />GALVANIZED WELDED WIRE FABRIC - ASTM A165 <br />REINFORCING STEEL SHALL BE DETAILED IN ACCORDANCE WITH ACI 315 "MANUAL OF STANDARD PRACTICE FOR DETAILING <br />REINFORCED CONCRETE STRUCTURES." <br />REINFORCING STEEL SHALL BE LAPPED AS NOTED ON THE DRAWINGS. WHERE LAP LENGTH IS NOT SHOWN, REINFORCING <br />BARS SHALL BE LAPPED AS FOLLOWS: <br />#5 AND SMALLER - 48 BAR DIAMETERS <br />#6 AND LARGER - 60 BAR DIAMETERS <br />MINIMUM CONCRETE COVER OVER REINFORCING SHALL BE AS FOLLOWS: <br />NONSTRUCTURAL SLAB -ON -GRADE - MID -DEPTH <br />WALL BARS: INTERIOR FACE - 3/4" <br />EXPOSED TO EARTH/WEATHER - 1.-1/2" (#5 AND SMALLER), 2" (#6 AND LARGER) <br />FOOTINGS: BOTTOM BARS - 3" (CAST AGAINST EARTH) <br />TOP BARS - 1-1/2" <br />SIDE BARS - 2" <br />PROVIDE SUPPORTS AS REQUIRED FOR PROPER ALIGNMENT AND CONCRETE COVER AROUND THE REINFORCEMENT. <br />CONSULT THE CRSI MANUAL OF STANDARD PRACTICE MSP-1 FOR SPECIFIC INFORMATION. <br />ANCHORS <br />USE OF DRILLED CONCRETE ANCHORS, INCLUDING EXPANSION BOLTS AND ADHESIVE ANCHORS, WHERE NOT SPECIFIED IN <br />THESE DOCUMENTS SHALL BE SUBJECT TO APPROVAL BY THE ENGINEER, ARCHITECT AND THE BUILDING INSPECTOR <br />EXPANSION BOLTS: EXPANSION BOLTS IN SOUD CONCRETE SHALL BE WEDGE -TYPE ANCHORS MADE OF CARBON STEEL. <br />BOLT SIZE, SPACING AND EMBEDMENT LENGTH SHALL BE AS DESIGNATED IN THESE DRAWINGS. BOLTS SHALL BE <br />INSTALLED PER THE MANUFACTURER'S INSTRUCTIONS WITH INSPECTION PER SCHEDULE. EXPANSION BOLTS SHALL BE <br />SIMPSON STRONG BOLT 2 OR APPROVED EQUAL. A CURRENT ICBO OR ICC REPORT SHALL BE SUBMITTED FOR <br />ALTERNATES. <br />ADHESIVE ANCHORS: ADHESIVE OR EPDXY TYPE ANCHORS IN SOLID CONCRETE SHALL BE INSTALLED PER THE <br />MANUFACTURER'S INSTRUCTIONS. ANCHOR SIZE, SPACING AND EMBEDMENT LENGTH SHALL BE AS DESIGNATED IN THESE <br />DRAWINGS. ADHESIVE SHALL BE SIMPSON AT-XP. A CURRENT ICBO OR ICC REPORT SHALL BE SUBMITTED FOR <br />ALTERNATES. <br />WOOD <br />SAWN LUMBER: STRUCTURAL SAWN LUMBER SHALL BE KILN DRIED AND BE OF THE SPECIES AND GRADE NOTED BELOW <br />OR BETTER: <br />USE GRADE FB (PSI) <br />WALL STUDS HEM FIR STUD 675 <br />PLATES, PLANKS, JOISTS, RAFTERS HEM FIR #2 850 <br />4X BEAMS HEM FIR #2 850 <br />6X BEAMS HEM FIR #2 675 <br />POSTS 4x HEM FIR #2 850 <br />POSTS 6x HEM FIR #2 575 <br />ALL WOOD CONNECTORS SHALL BE MANUFACTURED BY SIMPSON STRONG TIE COMPANY (OR APPROVED EQUAL), AND OF <br />THE SIZE AND TYPE SHOWN ON THE DRAWINGS. ALL WOOD CONNECTORS IN CONTACT WITH PRESERVATIVE -TREATED <br />WOOD SHALL BE TRIPLE ZINC G-185 GALVANIZED (1.85 OZ/SQ FT COATING). <br />ENGINEERED METAL -PLATE -CONNECTED WOOD TRUSSES SHALL BE DESIGNED BY A LICENSED PROFESSIONAL ENGINEER. <br />THE CONTRACTOR SHALL SUBMIT ENGINEERED TRUSS SHOP DRAWINGS TO THE STRUCTURAL ENGINEER OF RECORD FOR <br />REVIEW AND APPROVAL. TRUSS SHOP DRAWINGS SHALL BEAR THE SEAL AND SIGNATURE OF A LICENSED DESIGN <br />PROFESSIONAL CURRENTLY REGISTERED FOR PRACTICE IN THE STATE OF CT. SHOP DRAWINGS SHALL INDICATE ALL <br />LOADING CASES CONSIDERED, MAXIMUM DEFLECTIONS AND MAXIMUM END REACTIONS FOR EACH TYPICAL TRUSS <br />CONFIGURATION. TRUSS SHOP DRAWINGS SHALL INDICATE COMPRESSION MEMBERS REQUIRING ADDITIONAL <br />FIELD -INSTALLED LATERAL BRACING. TRUSS DEFLECTIONS SHALL BE LIMITED TO 1360 OF SPAN. <br />MINIMUM WOOD NAILING REQUIREMENTS: UNLESS OTHERWISE NOTED ON THE DRAWINGS, TYPICAL WOOD FRAMING SHALL <br />BE FASTENED PER IBC 2018 TABLE 2304,10.1. <br />RATED SHEATHING: STRUCTURAL PANELS SHALL BEAR THE APA TRADEMARK OF THE AMERICAN PLYWOOD ASSOCIATION. <br />SHEATHING SHALL BE AS FOLLOWS: <br />SHEAR WALL SHTG MIN. 7/16" 32/16 MIN, C-D INT APA WITH EXTERIOR GLUE (CDX) <br />ROOF SHTG MIN. 15/32" 32/16 MIN. C-D INT APA WITH EXTERIOR GLUE (CDX) <br />SUB FLOOR SHTG MIN. 3/4" 48/24 T&G MIN. C-D INT APA WITH EXTERIOR GLUE (CDX) <br />SHEATHING SHALL BE ORIENTATED OVER THE SUPPORTS AS SHOWN ON THE DRAWINGS. SHEAR WALL SHEATHING SHALL <br />BE BLOCKED AT ALL PANEL EDGES AS SHOWN IN THE SHEAR WALL SCHEDULE. <br />BUILDING OFFICIAL INSPECTIONS <br />THE FOLLOWING RECOMMENDED MINIMUM ITEMS SHALL BE INSPECTED BY A QUALIFIED INDIVIDUAL PROVIDED BY THE <br />BUILDING OFFICIAL: <br />-FOOTINGS BEAR ON COMPETENT NATIVE SOIL PER THE "FOUNDATIONS" SECTION ABOVE <br />-FOOTING REINFORCEMENT <br />-SHEAR WALL SILL PLATE ANCHORS AND WASHERS PER SCHEDULE <br />-SHEAR WALL NAILING AND SHEAR CLIPS PER SCHEDULE <br />-SHEAR WALL HOLD-DOWNS <br />-VERIFY TYPE, SIZE AND GRADE OF STRUCTURAL STEEL MEMBERS AND BOLTS <br />TYPICAL DETAILS <br />IN ADDITION TO THE DETAILS AND SCHEDULES ON THE FRAMING PLANS, THOSE NOTED AS "TYPICAL" SHALL BE USED <br />THROUGHOUT THE STRUCTURE AS APPLICABLE. <br />SHEET INDEX <br />S1.O STRUCTURAL NOTES <br />S2.0 FOUNDATION PLANS <br />S2.1 MAIN FLOOR FRAMING PLANS <br />S2.2 ROOF- FRAMING PLANS <br />S3.0 TYPICAL STRUCTURAL DETAILS <br />S3.1 TYPICAL STRUCTURAL DETAILS <br />ROOF <br />DESCRIPTION OF BUILDING ELEMENTS <br />NUMBER AND TYPE OF FASTENER <br />SPACING AND LOCATION <br />3-8d common (2 J" x 0.131'): or <br />1 <br />Blocking between ceiling joists, rafters or <br />3-1 Od box (3" x 0.1280); or <br />Each end, toenail <br />busses to tap plate or other framing below <br />3-3" x 0.131" nails; or <br />34' 14 gage staples, -,J" crown <br />2-8d common (2 � x 0.131") <br />2-3"x 0.131"nails <br />Each end, toenail <br />Blocking between rafters or truss not at the wall <br />2-3"14 gage staples <br />top plate, to rafter or truss <br />2-16.d common (3 i" x 0.162") <br />3-3" x 0.131" nails <br />End nail <br />3-3" 14 gage staples <br />16d common (3 }" x 0.162) Q 6" o.c. <br />Flat blocking to truss and web filler <br />3" x 0.131" nails Q 6" o.c. <br />3" x 14 gage staples @ 6".c <br />Face nail <br />3-8d common (2 x 0.1311; or <br />3-1 Od box (3" x 0.128"); or <br />2. <br />Ceiling joists to top. plate <br />3-3" x 0. 131" nails; or <br />Each joist, toenail <br />3.3" 14 gage staples, ?6" crown <br />3-1 Bid common (3 q" x 0.162"); or <br />Ceiling loist not attached to parallel rafter, laps <br />4-10d box (3' x 0.128"); or <br />3. <br />over partitions (no thrust) <br />4-3" x 0.131" nails; or <br />Face nail <br />(see Section 2308.7.3.1, Table 2308.7.3.1) <br />4-3' 14 gage staples, J' crown <br />4 <br />Ceiling joist attached to parallel rafter (heel joint) <br />(see Section 2308.7.3.1, Table 2308.7.3.1) <br />per Table 2308.7.3.1 <br />Face nail <br />3-10d common (3" x 0.148'); or <br />4-10d box (3" x 0.126"); or <br />5.. <br />Collar tie to rafter <br />4-3' x 0.131' nails;.or <br />pace nail <br />¢3"14 gage staples, 6 Glawn <br />3-10 common (3" x 0.148" ): or <br />3-16d box (3? x 0.135" ); or <br />B <br />Rafter or roof truss to top plate <br />4-10d box IT x 0.128" ); or <br />Toenail <br />(See Section 2308.7.5, Table 2308.7.5) <br />¢3" x 0.131 nails: or <br />4-3" 14 gage staples, J" crown <br />2-16d common (34' x 0.162"); or <br />3-10d box (3"x 0.1281; or <br />3-3" x 0.131' nails; or <br />End nail <br />3-3" 14 gage staples, - ." crown; or <br />7 <br />Roof rafters to doll valley or hip rafters; or roof <br />rafter to 2-inch ridge beam <br />3-1 Od common (3 }" x 0.148"); or <br />3-16d box (3 -" x 0.135"); or <br />4-1 Od box (3" z 0.128"); or <br />Toenail <br />4-3" x 0.131' nails; or <br />4-3" 14 gage staples. �" crosm <br />WALL <br />16d common (3 Z x 0.162") <br />24" o.c. face nail <br />8. <br />Stud to stud (not at braced wall panels). <br />10d box (3' x 0.128"); or <br />3' x 0.131' nails; or <br />16" o.c, face nail <br />3-3" 14 gage staples, k crown <br />16d common (3 }'x 0.162"); or <br />16" o.c. face nail <br />g' <br />Stud to stud and abutting studs at intersecting <br />16d box (3 J" x 0.135"); or <br />12" o.c. face nail <br />wall comers let braced wall panels) <br />3' z 0.131' nails; or <br />3-3' 14 gage staples, i" crown <br />12" o.c. face nail <br />16d common (3 } x 0.162"); or <br />16" o.c. each edge, face nail <br />10. <br />Built-up header (2" to T header) <br />16d box (3} x 0.135") <br />16" o.c. each edge, face nail <br />4-8d common (2+f"x 0.131"); or <br />11. <br />Continuous header to stud <br />4.10d box (3" x 0.128') <br />Toenail <br />16d common (3 7'" - 0.162'); or <br />16" o.c. face nail <br />12 <br />Top plateto top plate <br />10d box (3" x 0,128"); or <br />3" z 0-131" nails; or <br />12" o.c. face nail <br />3" 14 gage staples, 7' crown <br />8-16d common (3 J' x 0.162");or <br />12-1 Od box (3" x 0.128"); or <br />Each side of end joint, face nail <br />13. <br />Top plate to top plate, at end joints <br />12-3"x 0.131" nails; or <br />(minimum 24" lap splice length <br />12-3' 14 gage staples, J' crown <br />each side of end joint) <br />16d common 13 e x 0.162'); or <br />16" o.c. face nail <br />14 <br />Bottom plate to joist, rim joist, band joist or <br />16d box ( 31 x 0.135 '); or <br />blocking (notatbraced wall panels) <br />z' <br />3" x 0.131" nails; or <br />12" o.c. face nail <br />3" 14 gage staples, U crown <br />2-16d common (3}"x 0.162"); or <br />15, <br />Bottom plate to joist, rim joist, band joist or <br />3.16d box (3 } x 0.135"): or <br />blacking at braced wall panels <br />4-3" x 0.131' nails; or <br />16" o.c. face nail <br />43" 14 gage staples,?g" crown <br />4-8d common (2 1/2" x 0.131"); or <br />4-10d box (3" x 0.128"); or <br />43" x 0-131"nails: or <br />Toenail <br />4-3" 14 gage staples, 1" crown; or <br />16. <br />Stud to top or bottom plate <br />2-16d common (3 112" x 0.162"); or <br />3-10d box 13' x 0.128"); or <br />3-3" x 0.131" nails; or <br />End nail <br />3-3" 14 gage staples, s" crown <br />2-16d common (3 }" x 0.162"); or <br />17, <br />Top plates, laps at corners and intersections <br />3-10d box (3" x 0.128"); or <br />3-3" x 0.131" nails; or <br />Face nail <br />3-3" 14 gage staples, *. " crown <br />2-8d common (2 }" x 0.131"); or <br />18. <br />1" brace to each stud and plate <br />. <br />2-1 Od box(3" x 0.128'); or2 3" x 0.131' nails; or <br />-Face nail <br />2-3" 14 gage staples, �6 crown <br />19, <br />1" x 6" sheathing to each beadng <br />2-8d common (2112" x 0.131"): or <br />Face nail <br />2-10d box (3" x 0.128") <br />20. <br />1" x 8" and wider sheathing to each bearing <br />2-8d common (2112" x 0.131"); or <br />3-10d box (3" x 0.128") <br />Face nail <br />CITY OF EVERETT <br />Permit Services <br />WOOD STRUCTURAL PANELS (WSP), SUBFLOOR, ROOF AND <br />INTERIOR WALL SHEATHING TO FRAMING AND <br />PARTICLEBOARD WALL SHEATHING TO FRAMINGa <br />Edges <br />Intermediate supports <br />(inches) <br />(inches) <br />fid common or deformed (2" x 0.113") <br />(sybfioorand wall) <br />6 <br />12 <br />Sol box or deformed (2 �,L" x 0.113") (roof) <br />6 <br />12 <br />2 " x 0.113' nail(subfioor and. wall). <br />6 <br />1 <br />30. <br />g" -Y2" <br />1" 16 gage staple, le" crown <br />(subfloor and wall) <br />4 <br />8 <br />2 e" x 0.113" nail (root) <br />4 <br />8 <br />1 " 16 gage staple, k crown (roof) <br />3 <br />6 <br />Bid common (2}"x:0.131"):.or <br />6d deformed (2" x 0.113") <br />6 <br />12 <br />31. <br />19�32 " - 3�4' <br />2J"x0.113"nail; or <br />2" 16 gage staple, AP crown <br />4 <br />8 <br />32. <br />7/8, - 1 Yq" <br />10d common (3' x 0.148"); or <br />ad deformed (2}" x 0.131") <br />6 <br />12 <br />OTHER EXTERIOR WALL SHEATHING <br />33. <br />Y2" fiberboard sheathingb <br />1 J" galvanized roofing nail <br />(y" head diameter); or <br />1. }" 16 gage staple with,i" or 1" crown <br />3 <br />6 <br />34. <br />25/32' fiberboard sheathing' <br />1 +J" galvanized roofing nail <br />(?g" diameter head): or <br />1 J" 16 gage staple with-&" or ,"crown <br />3 <br />6 <br />WOOD STRUCTURAL PANELS, COMBINATION SUBFLOOR <br />UNDERLAYMENT TO FRAMING <br />Edges <br />Intermediate supports <br />(inches) <br />(inches) <br />35. <br />3/4" and less <br />Bid common (2 � x 0.1317; or <br />6d deformed (2' x 0.113") <br />6 <br />12 <br />36. <br />7 <br />YS 1" <br />lid common (2 i x 0.131'); or <br />Bd deformed (2'� x 0.131') <br />6 <br />12 <br />37. <br />" and less <br />ad common (2 } x 0.131 "); or <br />6d deformed IT x 0.113") <br />6 <br />12 <br />PANEL SIDING TO FRAMING <br />38." <br />or less <br />6d corrosion -resistant siding <br />(1 a" x 0.106"); or <br />6d corrosion -resistant casing (2" x 0.,099") <br />6 <br />12 <br />8dcorrosion-resistant siding <br />39. <br />5 <br />(2? x 0.1281; or <br />Sol corrosion -resistant casing <br />6 <br />12 <br />(2 }" x 0.113') <br />INTERIOR PANELING <br />40. <br />y" <br />4d casing (I J' x 0.080"); or <br />4d finish (1 # x 0.07E") <br />6 <br />12 <br />41, <br />3/8„ <br />6d casing (2" x 0-099"); or <br />6d finish (Panel supports at 24 inches) <br />6 <br />12 <br />For SI: 1 inch = 25.4 mm. <br />a. Nails spaced at 6inches at intermediate supports where spans are 48 inches or more. For nailing of wood structural panel and particleboard <br />diaphragms and shear walls refer to Section <br />cb n 2305. Nails for wall sheathing are permitted to be common, box or casing.. <br />b. Spacing shall be 6 inches on center on the edges and 12 inches oncenter at. intermediate supports for nonstructural applications. Panel <br />supports at 16 inches (20inches if strength axis in the long direction of the panel, unless otherwise marked). - <br />c. Where a rafter is fastened to an adjacentparallel ceiling joist in accordance with this schedule and the ceiling joist is fastened to the top plate in <br />accordance with this schedule, the number of toenails in the rafter shall be permitted to be reduced by one nail <br />Additional Permits Are Required <br />For This Project To Include: <br />� Plumbing <br />Mechanical <br />Z Electrical <br />❑ Sprinkler <br />❑ Fire Alarm <br />THESE DOCUMENTS HAVE <br />NOT BEEN APPROVED FOR THE <br />ISSUANCE OF PUBLIC WORKS, <br />MECHANICAL, FIRE SUPPRESSION, <br />ELECTRICAL OR PLUMBING PERMITS. <br />All electrical, mechanical, plumbing <br />and framing installedlaltere withoust <br />permit, inspection, and approval <br />De uncovered for inspection. <br />CITY OF E\IERETT <br />Rc�lIEWED FOR PERM9T <br />Smoke Detectors Required <br />a in each sleeping room, <br />a In each room giving access to a <br />sleeping room, <br />a Interconnected, <br />a Battery backup, <br />Hardwired. <br />Permit#: <br />BW2012-002 <br />Site Address: <br />3825 COLBY AVE <br />Owner: <br />MCK PROPERTIES LLC <br />App.Date: <br />12/30/2020 <br />Proposed Use: <br />RESIDENTIAL ALTERATIONS <br />Description: <br />SFR REMODELTO ABATE UNPERMITTED <br />ALTERATIONS <br />Reviewed By: <br />P�-- <br />p : j1!?-1Z&Z-L <br />Office Set <br />Job Site Set -Fire/Planning <br />Set <br />Cr <br />G 0 <br />O <br />UI U <br />J <br />W Q <br />O Ur <br />L N <br />r N 00 <br />� ZU <br />O Z W <br />C.)O H <br />i1 LL <br />.I <br />v W <br />Z <br />`W <br />r <br />r <br />54334 <br />0 GIST 4 <br />-SSIONAL IV <br />P 212/2022 <br />V <br />Z <br />.J <br />W <br />0 <br />W\ <br />/ <br />0 <br />CO <br />C <br />0) <br />J <br />O <br />m <br />U <br />J <br />L0 <br />O <br />(') <br />LU <br />LO <br />00 <br />co <br />JOB # <br />2022007 <br />"ALL ELECTRICAL, MECHANICAL, <br />PLUMBING, FRAMING INSTALLED <br />OR ALTERED WITHOUT PERMITS <br />OR INSPECTION OR APPROVAL <br />MUST BE UNCOVERED FOR <br />INSPECTION" <br />Drawn By: <br />Drawing Title: <br />STRUCTURAL <br />NOTES <br />Sheet <br />S1.0 <br />