Laserfiche WebLink
2015 Washington State Er. Code Compliance Forms for Commercial,R2 and R3 over fries and all R1-Page 3 of 17 <br /> Permit Plans <br /> 2015 Washington State Energy Code Compliance Fortes for Commercial Buildings including R2&R3 over 3 stories and all R1 Revised January 2017 <br /> Project Tine: Everett Community College-Learning Resource Center Date 7/24/2020 <br /> The following information is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the <br /> Washington State Energy Code,Commercial Provisions. <br /> Applicable Location in Building Department <br /> Code Section Code Provision Information Required-Must be in permit documents <br /> (Yes,no,na) Documents Notes <br /> Equipment-Sizing,Performance and Type <br /> Identify equipment to be used in manufacturing,industrial or commercial processes that do not - <br /> NA C403.1 Exempt process equipment provide space conditioning;identify provisions applicable to this equipment per C403.1 <br /> exception <br /> Provide load calculations performed per ASHRAE Sid 183 or equivalent,using design See <br /> Yes C403.2,1 Load calculations parameters per C302 and Appendix C;include load adjustments to account for energy Attached <br /> recovery <br /> Equipment and system Indicate that output capacities of heating and cooling equipment and systems are no greater MO Series <br /> Yes C403,2.2 than the smallest available equipment size that exceeds the calculated loads;note exceptions <br /> sizing <br /> taken <br /> C403.2.3 HVAC equipment Provide equipment schedules on plans or complete MECH-EO forms indicating type,capacity, MO Series <br /> Yes C403.2.3.2 performance requirements rated and WSEC minimum efficiencies for all heating and cooling equipment;include supply <br /> C403.2.13.1 (efficiency) and OSA alms and operating hours for all air systems;identify heating and cooling equipment <br /> that does not have a corresponding WSEC minimum efficiency(manufacturer rated) <br /> List all motors a 1/12 hp(that are not integral to a rated piece of equipment)in the mechanical MO Series <br /> C405.8 or electrical equipment schedules on plans;indicate hp,rpm,number of poles and rated <br /> Yes C403.2,14 Electric motor efficiency efficiency,or exception applied <br /> For fractional hp motors(1/12-1 hp),indicate whetherthey are an electronically commutated MO Series <br /> motor,have rated efficiency of at least 70%,or exception taken <br /> For all HVAC fan systems that provide heating and/or cooling,provide system total See MECH <br /> nameplate hp in MECH-FANSYS-SUM form FANSYS <br /> Yes C403.2.11.1 Fan power limitation For all applicable HVAC systems with total fan motor hp>5hp,verify fan system motor hp or See MECH <br /> bhp complies with fan power limits per equations in Table C403.2.11.1(1),provide MECH- FANSYS <br /> FANSYS form for each system <br /> See MECH <br /> For all applicable HVAC systems with total fan motor hp>Shp,indicate fan motors specified <br /> Yes C4032.11.2 Motor nameplate hp SYS <br /> are the smallest available motor hp size greater than fan bhp,note exceptions taken and MO <br /> and MO <br /> For all applicable HVAC systems with total fan motor hp>Shp,identify in equipment schedule MO Series <br /> Yes C403.2.11.3 Fan efficiency all fans required to comply with fan efficiency grade and indicate rated FEG is a 67,or <br /> exception taken;indicate these fans are sized so total efficiency is within 15%of the fan <br /> maximum total efficiency <br /> NA C403.2.1 t.4 Group R occupancy exhaust For all exhaust fans c 400 cfm in Group R occupancies,indicate in equipment schedule the <br /> fan efficacy fan flow rate and efficacy(cfmlwatt),or exception taken;refer to Table C403.2.11.4(CE-57) <br /> Variable flow capacity- For fan motors a TS hp,indicate method of variable flow control(VSD or equivalent method)in MO Series, <br /> Yes C403.2.13 fans equipment schedule,or excepfion taken;for equivalent method for an HVAC system refer to M10 Series <br /> HVAC System Controls for additional requirements <br /> NA C403.2.3 Maximum air cooled chiller For chilled water plants and buildings with>500 tons of cooling capacity,indicate air-cooled - <br /> capacity chiller capacity is s 100 tons,or exception taken <br /> Large capacity cooling For buildings with>_300 tons of cooling capacity,indicate method of multi-stage or variable - <br /> NA C403.4 systems capacity control(VSD,multiple staged compressors,or max capacity of any single unit a 66% <br /> of the total) <br /> Non-standard water-cooled For water-cooled centrifugal chillers not designed for operation at standard conditions,provide - <br /> NA C403.2.3.1 centrifugal chillers calculations documenting maximum full load and part load rated equipment performance <br /> requirements <br /> NA C403.2.13.1 Centrifugal fan open-circuft For open-circuit centrifugal fan cooling towers with a 1,100 gpm capacity,indicate cooling - <br /> C403.4.3.2 cooling towers towers comply with efficiency requirements for axial fan open circuit cooling towers <br /> For single boilers with>500,000 Bluth capacity,indicate multi-stage or modulating burner NA <br /> Yes C403.4.2 Large capacity boiler For boiler system(single or multiple)with>1,000,000 Btu/h capacity,indicate turndown ratio MO Series, <br /> C403.4.2.5 systems per Table C403.4.2.5 and method(multiple single input boilers,modulating boilers,or M10 Series <br /> combination) <br /> Variable flow capacity- For pump motors t 7.5 hp,indicate method of variable flow control(VSD or equivalent MO Series, <br /> Yes C403.2.13 method)in equipment schedule,or exception taken;for equivalent method for a hydronic M10 Series <br /> pumps system refer to Hydronic System Controls for additional requirements <br /> NA C403.2.3 Gas and oil-fired forced air For forced air furnaces with capacity z 225,000 Btu/h and all unit heaters,indicate in <br /> furnace and unit heaters equipment schedule intermittent ignition or IID,flue or draft damper,and rated jacket loss <br /> NA C403.2.4,8 Combustion heating For combustion heating equipment with output capacity>225,000 Btu/h,indicate modulating <br /> equipment or staged combustion control <br /> Yes C403.2.3.3 Packaged electric heating! Verify all packaged electric equipment with>6,000 Btu/h cooling capacity and any amount of <br /> cooling equipment heating is a heat pump;include in equipment schedules <br /> NA C403.2.12 Heating outside a building Indicate systems providing heating in non-enclosed outdoor occupied spaces are radiant <br /> systems;refer to HVAC System Controls for additional requirements <br /> NA C403.2.7.1 Kitchen exhaust hoods Indicate on plans the type,duty and exhaust air rate of each kitchen hood,refer to HVAC <br /> System Controls for additional requirements <br /> ! <br /> Indicate locations of OSA intake,and exhaust and relief outlet dampers on plans;indicate MO Series <br /> Yes C403.2.4.3 Outdoor supply air,exhaust whether dampers are Class 1 motorized,or gravity and exception taken(include leakage Spec <br /> and relief dampers rating,cfm/s�;refer to HVAC System Controls for additional requirements for OSA dampers <br /> Indicate locations of return air dampers that are integral to economizer operation;verify <br /> NA C403.2.4.3 Return air dampers dampers are motorized;indicate whether dampers are Class 1,or within packaged equipment <br /> eligible for leakage rating exception(include leakage rating,cfm/sf) <br /> -- .... <br />