My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1001 N BROADWAY LEARNING RESOURCE CENTER 2026-01-15
>
Address Records
>
N BROADWAY
>
1001
>
LEARNING RESOURCE CENTER
>
1001 N BROADWAY LEARNING RESOURCE CENTER 2026-01-15
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/15/2026 8:47:21 AM
Creation date
9/23/2025 9:58:56 AM
Metadata
Fields
Template:
Address Document
Street Name
N BROADWAY
Street Number
1001
Tenant Name
LEARNING RESOURCE CENTER
Imported From Microfiche
No
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
1616
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2015 Washington State Er, r Code Compliance Forms for Commercial,R2 and R3 over,...-cries and all R1-Page 11 of 17 <br /> 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2&R3 over 3 stones and all R1 Revised January 2017 <br /> Project Title: Everett Community College-Learning Resource Center Date 7/24/2020 <br /> The following information is necessary to check a permit application for compliance with the mechanicial systems and equipment requirements of the <br /> Washington State Energy Code,Commercial Provisions. <br /> Applicable Loc�wnn Building Department <br /> (yes,no,na) Code Section Code Provision Information Required-Must be in permit documentsDocts Notes <br /> Equipment-Sizing,Performance and Type <br /> Yes C404.2 SWH equipment type and Provide equipment schedule on plans indicating type and capacity;indicate efficiency complies <br /> efficiency with required federal standard MO Series <br /> For individual SWH equipment serving an entire building with a 1,000,000 Btu/h capacity, <br /> indicate thermal efficiency a 90%;or exception taken <br /> High input-rated SWH For buildings with aggregate capacity of all SHW equipment a 1,000,000 Btu/h(exclude< <br /> NA C404.2.1 stems 100,000 Btu/h equipment from threshold calculation),indicate average capacity weighted <br /> thermal efficiency a 90%;or exception taken <br /> If applying Exception 1 for site-solar or site-recovered energy,provide calculations and source <br /> of annual service water heating energy use estimate <br /> Yes C404A Heat traps Indicate piping connected toequipment have heat traps on supply and discharge M2 Series. <br /> p p 9p pp y M9 Series <br /> NA C404.5 Insulation under electric For electric water heaters located in unconditioned spaces or on concrete floors,indicate R-10 <br /> water heater insulation under e ui ment NA <br /> Piping Systems <br /> Indicate thickness of piping insulation on plans per Table C403.2.9;verify insulation is provided <br /> Yes C404.6 Insulation of piping - from the water heater to the final fixture in a line,from the inlet/outlet piping at water heater <br /> to heat trap(up to 8 feet),and on piping that is heat traced;note exceptions taken <br /> MO Series <br /> Indicate method of compliance on plans for all piping runs connecting service hot water source <br /> Yes C404,3 Efficient SWH supply piping to hot water fixture(maximum pipe length or maximum pipe volume method per Table <br /> C404.3.1);provide calculations for all piping runs documenting the total length and/or volume MO Series <br /> Service Water Heating System Controls <br /> For circulation systems with dedicated return piping,indicate controls are configured to <br /> automatically start pump based on demand for hot water and shut-off pump when there is no <br /> C404.7.1 Heated-water circulating demand and when the desired water temperature is met MI Series <br /> Yes or circulations stems with cold water supply C404.8 systems F Y piping serving as the return,indicate controls <br /> are configured to automatically start pump based on demand for hot water and shut-off pump <br /> when there is no demand,or when temperature of water entering the cold water supply pipe is <br /> a 1041E <br /> M10 Series <br /> For heat trace systems provided to maintain temperature of service hot water in piping, <br /> NA C404.7.2 Heat trace system controls indicate controls are configured to de-energize system when there is no demand for hot water <br /> and when the desired water temperature is met <br /> Yes C404.7.3 Controls for hot water For systems with separate water heater and storage tank,indicate controls are configured to <br /> storage limit operation time of pump after end of heating cycle to 5 5 minutes M10 Series <br /> For SWH,pool/spa and pressure boosting pump motors a 7.5 hp,indicate method of variable <br /> C403.2.13 Variable flow control- flow control(VSD or equivalent method that requires a 30%design wattage at 50%design <br /> Yes C403.4.2.7 pumps fluid flow);note exception taken NA <br /> identify basis of pump speed control(differential or static pressure setpoint,pressure,zone <br /> load demand,etc) M10 Series <br /> Pools and Permanent Spas-Equipment and Controls(Sections are under C404.11) <br /> NA C404.10.1 <br /> Pool heating equipment Provide equipment schedule on plans indicating type and capacity for all pool heating <br /> efficiency equipment;indicate efficiency complies with required federal standard;for heat pump water <br /> heaters indicate COP>_4 <br /> NA C403.2.13 P��Pse flow control- Refer to Service Water Heating System Controls <br /> NA C404.10.1 Pool heater on 1 off controls Indicate automatic on/off control based on scheduling and readily accessible on/off switch <br /> C404.10.2 on heater that operates independent of thermostat setting;note exceptions taken <br /> NA For all pools and in-ground permanent spas,indicate a vapor retardant cover on plans <br /> C404.10.3 Pool rovers NA For all pools and in-ground spas heated to>901F,indicate cover shall include insulation a R- <br /> 12 <br /> NA C404.10.3 Pool assembly insulation For all pools and in-ground spas heated to>901F,Indicate on plans that sides and bottom are <br /> provided with insulation>-R-12 <br /> NA C404.12 Energy consumption of Indicate portable spa complies with Association of Pool and Spa Professionals APSP-14 <br /> portable spas <br />
The URL can be used to link to this page
Your browser does not support the video tag.