My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1411 WALL ST 2024 Plans 2025-09-24
>
Address Records
>
WALL ST
>
1411
>
Plans
>
1411 WALL ST 2024 Plans 2025-09-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/24/2025 6:59:39 AM
Creation date
9/24/2025 6:59:36 AM
Metadata
Fields
Template:
Address Document
Street Name
WALL ST
Street Number
1411
Permit
FA2402-010
Year
2024
Notes
FIRE ALARM MODIFICATION
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
Page 1 of 1
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FA2 <br /> AW <br /> Permit#: 1411 Wall S �r <br /> Site Address: 1411 Wall St <br /> E CORE Applicant Fire Protection Inc <br /> Application Date:02/19/2024 FIRE PROTECT/ON INC. <br /> Description: Fire Alarm Modification 1 Ash Way,Ste 8 <br /> ReFU LL U view Date: 02/21/2024 Lynnwood,WA 98037 <br /> 425-290-9600 <br /> FPISEATTLE.COM <br /> AES RADO STAAT 0 EV`TT EST <br /> Everett Fire Dept.Permit Review 1 <br /> Status:Approved <br /> Reviewed By:KBrown <br /> 02/21/2024 12:35:42 <br /> REPORTING ZONE FROM RADIO TYPICAL INSTALLATION DETAIL SHEET/NDEX NFPA® <br /> SHEET # SHEET DESCRIPTION 000805173 <br /> FA 0.0 FIRE ALARM AES INSTALLATION ROY L CATS <br /> CENTRAL STATION REPORTING ZONES <br /> QpOTECTj <br /> ZONE # ZONE DESCRIPTION PROJECT DETAILSIn <br /> 1 GENERAL ALARM LL <br /> 2 SUPERVISORY 1. THE EXISTING TWO—STORY BUILDING IS FULLY—SPRINKLED AND HAS AN EXISTING CONVENTIONAL FIRE ALARM ry NFPA �^ <br /> CONTROL PANEL(SILENT KNIGHT 5208 FIRE PANEL) LOCATED BY THE SPRINKLER SYSTEM IN THE STORAGE <br /> 3 TROUBLE Room. CFPS <br /> 2. A NEW UL LISTED WIRELESS RADIO COMMUNICATOR (7707-88—ULP) IS BEING INSTALLED, SIGNALS WILL BE #1473 <br /> TRANSMITTED BY ZONE TO THE UL LISTED SUPERVISING STATION. A 12VDC 12Ah BATTERY WILL BE <br /> INSTALLED IN THE NEW AES RADIO. <br /> Oc Oc 3. THE NEW AES RADIO WILL USE THE EXISTING FACPS DIALER TO SEND CONTACT ID AND ONBOARD RELAYS <br /> VICINITY MAP TO TRANSMIT THE FOLLOWING HARDWIRED SIGNALS TO THE CENTRAL SUPERVISING STATION: ZONE 1: FIRE <br /> O O O O O ALARM /WATERFLOW, ZONE 2: SUPERVISORY, AND ZONE 3: TROUBLE. u n <br /> = a <br /> ji® O O O O O 4. NO CHANGES TO THE EXISTING SYSTEM WILL BE MADE, NO ADDITIONAL WORK IS INCLUDED IN THIS SCOPE. W Z ao <br /> �t--�. srAius mnXcnrorts Z w � <br /> 0 <br /> ~V W <br /> Providence 1 I ¢ a W <br /> Q Regional II O 0 o PROJECT CONTACT INFO w m a y <br /> C. <br /> Medical Center ® a z o <br /> J 0 ¢E m <br /> © TROCHE sue OWNER/TENANT FIRE ALARM CONTRACTOR esi u rmj <br /> O O FULL LIFE CARE FIRE PROTECTION INC o o <br /> 1980 112TH AVE NE, Ste 210 17410 ASH WAY, Ste 8 = w rc a <br /> TF,mw TRrmw BELLEVUE, WA 98004 LYNNWOOD, WA 98037 ma. O <br /> CONTA© ® ® PHHONECT 206MILY 316.680ERTS CONTAPHONE DAVID MOW <br /> 425 290.600 m w G <br /> EMILY.ROBERTSOFULLLIFECARE.ORG DAVIDOFPISEATTLE.COM <br /> O 00000000 O mrcwa�a m <br /> 4- ZONES 1-8 WPU1 REVISION RECORD <br /> Q Everett - _- S CODE INFO DATE DESCRIPTION <br /> maae0amaa a. ,6 sls <br /> FU11 Life Cafe Sf10110rYIISn AUTHORITY HAVING JURISDICTION : CITY OF EVERETT <br /> County Adult Day FIRE CODE : INTERNATIONAL FIRE CODE, 2018 EDITION <br /> Health Center BUILDING USE AND OCCUPANCY : (B) — SPRINKLED <br /> E L/� <br /> _ STANDARDS: 2018 IBC/IFC, 2017 NFPA 70, 2016 NFPA 72, CITY OF EVERETT STANDARDS <br /> DeD CATeD�pvAc CLASSIFICATION OF SUPERVISING STATION CENTRAL SUPERVISING STATION <br /> 12vl 2Ah REMOTE SUPERVISING STATION : SECURITAS, INC. <br /> BA ERY PRIME FIRE ALARM CONTRACTOR : FIRE PROTECTION, INC. <br /> PARCEL NUMBERS 00439168101500 <br /> EXISTING OCI IIONALFACP(SEENTKIUGHT 5208 FIRE PAXEL) INSTALLATION NOTES <br /> AES-7707-88-LILP RADIO CONMJMCATOR <br /> TYPICAL WIItINC ANDINSTAITATIONDI TAIT$ 1. ALL WORK SHALL BE IN ACCORDANCE WITH NFPA STANDARDS AND ALL LOCAL ADOPTED CODES. <br /> 2. ALL CIRCUITS MUST BE TESTED FOR OPENS, CONTINUITY, SHORTS, AND GROUNDS. <br /> 3. INSTRUCTIONS FOR THE OPERATING, TESTING AND MAINTENANCE OF THE SYSTEM, ALONG WITH RECORD <br /> DRAWINGS OTHERWISE REFERRED TO AS ("AS—BUILT") AND EQUIPMENT SPECIFICATIONS SHALL BE <br /> PROVIDED TO THE OWNER ONCE THE FIRE ALARM SYSTEM HAS BEEN ACCEPTED BY THE AHJ. . <br /> SITE PLAN SEQUENCE OF OPERATIONS <br /> 4. ALL SYSTEMS AND DEVICES SHALL BE INSTALLED AND TESTED PER THE MANUFACTURES LISTING AND THE <br /> AUTHORITY HAVING JURISDICTION (NFPA72 10.14.2.1). DATE: 02/13/2024 <br /> SYSTEM OUTPUTS 5. THE SYSTEM WILL BE 100% PRE—TESTED, AN NFPA 72 COMPLETION FORM WILL BE FILLED OUT AND PROJECT NAME <br /> Required Fire Safety Control PROVIDED TO THE AHJ AND THE ELECTRICAL PERMITS MUST BE SIGNED OFF PRIOR TO THE FIRE FINAL <br /> Central Supervising Station roe INSPECTION. <br /> Control Unit Annunciation ,� 6. THE AES RADIO REQUIRES A DEDICATED 120VAC 20AMP CIRCUIT. A NOTICE PLACED IN THE FACP SHALL <br /> ti �01 DIRECT PERSONNEL TO THE LOCATION OF THE ELECTRICAL PANEL THAT IS SUPPLYING DEDICATED POWER <br /> IF TO THE SYSTEM (NFPA72, SECTION 10.5.5.1). THE DEDICATED CIRCUIT BREAKER THAT SERVES THE FIRE <br /> HEWITT AVE o4. ,o m` me ®° ALARM SYSTEM SHALL BE LABELED AND SECURED AGAINST TAMPERING WITH A RED BREAKER LOCKOUT <br /> m cov y (NFPA72, SECTION 10.5.5.2). <br /> W > C4 <br /> yzF o�c DEVICE INSTALLATION REQUIREMENTS Q Q rn <br /> y Co o yJ Se 20 a U W Q <br /> U. <br /> FIRE ALARM DEVICE INSTALLATION REQUIREMENTS J j <br /> ® OJ O <br /> A p Q O <br /> Ja O� O g 3 e NOT PERMITTED J IY LIJ <br /> CE O Q e= moD Zy BRACKET eox ACT DIFFUSER HERE a' : M W <br /> ZO m D Ja Ja Ja!`t yJQ!G yam@ Jm cRlo T/ LL N <br /> A G QQQ m /N11 W <br /> < BITBIT c c CeF CBE`m`� FA DEVICE CEILING III&, <br /> DETECTOR SMOKE 4 <br /> 4 O V `ry `ry try `ry 4 4 MINIMUM 3' <br /> AWAV FROM NOT PERMITTED 12" <br /> SYSTEM INPUTS B C D E F G H I HVAC DIFFUSERS HERE <br /> MOKE <br /> 1 Manual Fire Alarm Pull-Station ♦ ♦♦ 1 H S <br /> 2 Smoke&Heat Detectors ♦ ♦♦ 2 <br /> FACP a 3 wet Waterflow ♦ ♦ ♦♦♦ 3 J SHEET TITLE <br /> MAX HEIGHT 92"All <br /> 4 Unused ♦ ♦ ♦♦ 4 MIN HEIGHT 82"A.F.F <br /> 5SPR1NKLE7RRCOM = 5 Sprinkler Tamper/PIV ♦ ♦ 5 <br /> WALL STN 6 Unused ♦ ♦ 6 FIRE ALARM <br /> J7 Fire Alarm AC Power Failure ♦ ♦ 7 m"A.F.F eo•AFF O PROJECT DETAILS <br /> m 8 Fire Alarm System Low Battery ♦ ♦ 819 PULL <br /> 9 Open Circuit ♦ ♦ 9 aa"A.F.F <br /> Nfo Ground Fault ♦ ♦ fo SHEET NUMBER <br /> A B C D E F G H K <br /> Not to Scale FA <br /> O.O <br />
The URL can be used to link to this page
Your browser does not support the video tag.