O O <br /> Permit#: FA2403-010 7 <br /> Site Address: 3201 Smith Ave ZTL <br /> Applicant: Fire Protection Inc <br /> Application Date:03/25/2024 FIRE PROTECTION INC. <br /> EVERETT RAIN STA ION Description: Replacement of the Existing Fire 17410 Ash Way,Ste 8 <br /> Alarm System Lynnwood,WA 98037 <br /> Review Date: 03/27/2024 (425)290-9600 <br /> FIRE ALARM SYSTEM REPLACEMENT MEwww.fpiseattle.com <br /> EVERETT <br /> Everett Fire Dept.Permit Review <br /> Status:Approved <br /> Reviewed By:KBrown <br /> 03/27/2024 11:29:55 <br /> AM <br /> PROJECT INSTALLATION NOTES DEVICE/EQUIPMENT LEGEND SHEET INDEX NFPA <br /> SHEET# SHEET DESCRIPTION SHEET# SHEET DESCRIPTION 000805173 <br /> 1. THESE DRAWINGS ARE DIAGRAMMATIC.REFER TO THE ARCHITECTURAL,MECHANICAL,FIRE PROTECTION,AND ELECTRICAL SYMBOL CITY MANUFACTURER PART NO DESCRIPTION FA 0.0 FIRE ALARM REPLACEMENT-PROJECT DETAILS FA 7.0 FIRE ALARM REPLACEMENT-SEC RISER DIAGRAM <br /> DRAWINGS FOR TRADE SPECIFIC DETAILS. ROY L CATS <br /> 1 GAMEWELL FCI E3 SERIES FRCP ADDRESSABLE UUKL LISTED FRCP FA 0.1 FIRE ALARM REPLACEMENT-PROJECT DETAILS CONTINUED FA 8.0 FIRE ALARM REPLACEMENT-NAC RISER DIAGRAM <br /> 2. WIRING DEPICTED ON THESE PLANS ARE FROM BUILDING'S FIRE ALARM AS-BUILT DRAWINGS. 1 HONEYWELL HON-OGW-MBB CLSS GATEWAY ONLY FA 1.0 FIRE ALARM REPLACEMENT-BASEMENT FLOOR PLAN FA 9.0 BATTERY AND VOLTAGE DROP CALCULATIONS Q�QPOTECTj02 <br /> 1 GAMEWELL FCI LCD-E3 LCD KEYPAD DISPLAY FA 2.0 FIRE ALARM REPLACEMENT-1ST FLOOR PLAN FA 9.1 BATTERY AND VOLTAGE DROP CALCULATIONS-CONTINUED a i <br /> 3. THE EXISTING FACP,VOICE EVAC AMPLIFIER AND REMOTE POWER SUPPLIES SHALL BE REPLACED. 1 GAMEWELL FCI E31D2-C ASSY,INNER DOOR,COMMAND CENTER,2-BAY'C'SIZE FA 3.0 FIRE ALARM REPLACEMENT-2ND FLOOR PLAN FA 9.2 BATTERY AND VOLTAGE DROP CALCULATIONS-CONTINUED ,W-.. m <br /> cool <br /> 1 GAMEWELL FCI E3-INCC-CPLATE COMMAND CENTER MODULE MOUNTING PLATE,'C'SIZE FA 4.0 FIRE ALARM REPLACEMENT-3RD FLOOR PLAN FA 9.3 BATTERY AND VOLTAGE DROP CALCULATIONS-CONTINUED rb NFPA <br /> 4. THE EXISTING ADDRESSABLE INITIATING AND CONTROL DEVICES/MODULES SHALL BE REPLACED. FACP dJ y <br /> 1 GAMEWELL FCI ILI-MB-E3 INTELLIGENT LOOP INTERFACE-MAIN BOARD FA 5.0 FIRE ALARM REPLACEMENT-4TH FLOOR PLAN FA 10.0 VOICE EVACUATION SPEAKER SCHEDULE CFPS <br /> 5. THE EXISTING PERIPHERAL DEVICES SHALL BE REPLACED. 1 GAMEWELL FCI ASM-16 ADDRESSABLE SWITCH MODULE FA6.0 FIRE ALARM REPLACEMENT-ROOFPLAN FA10.1 VOICE EVACUATION SPEAKER SCHEDULE-CONTINUED #1473 <br /> 1 GAMEWELL FCI E3BB-BCIINCC ENCLOSURE,COMMAND CENTER,BLACK,'C'SIZE <br /> 6. THE EXISTING FIRE ALARM WIRING SHALL REMAIN AND BE REUSED. 1 GAMEWELL FCI 1100-0452 INCC-MIC PAGING MICROPHONE MODULE PROJECT NARRATIVE <br /> 7. THE EXISTING SMOKE CONTROL PANEL,DOOR HOLDERS,DAMPERS,AND CONVENTIONAL RELAYS SHALL REMAIN AS-IS. 1 GAMEWELL FCI PM-9 POWER SUPPLY CARD u <br /> 1 GAMEWELL FCI LCD-E3IE3BB-FLUSH-LCD LCD KEYPAD DISPLAY W/E3BB-FLUSH-LCD FIRE ALARM SYSTEM REPLACEMENT: <br /> FAA W <br /> 8. NEW PERIPHERAL DEVICES WILL BE INSTALLED IN AREAS LACKING CODE-COMPLIANT COVERAGE. 1 GAMEWELL FCI LCD-E3 LCD KEYPAD DISPLAY OUTLINED BELOW IS THE SCOPE OF WORK FOR THE REPLACEMENT OF THE EVERETT TRAIN STATION'S EXISTING F w w <br /> W w W <br /> 1 GAMEWELL FCI INX-CAB-B EMERGENCY VOICE EVAC AMPLIFIER 150WATTS (SIMPLEX)ADDRESSABLE FIRE ALARM SYSTEM WITH VOICE EVACUATION AND SMOKE EVACUATION.THE EXISTING SIMPLEX °i W, <br /> 9. THE SMOKE CONTROL PANEL SHALL BE OFF IN THE NON-ALARM CONDITION.CORRIDOR FIRE/SMOKE DAMPERS SHALL BE OPEN ON H <br /> 1 GAMEWELL FCI PM5 W ZN POWER SUPPLY CARD N <br /> NON-ALARM CONDITION. 0 4100 FACP IS OBSOLETE, IT INITIALLY CAME TO MARKET IN 1988,PHASED OUT STARTING 2002,BEING REPLACED WITH 41000 a do.0 _ <br /> 3 GAMEWELL FCI AM-50-70 AMP CARD,AMS0,70.7VRMS,50 WATT, p u# <br /> UNTIL 2011,PHASED OUT AND REPLACED WITH 4100ES. rc <br /> 10. SMOKE CONTROL SYSTEM ACCEPTANCE TESTING MUST BE PERFORMED BY A SPECIAL INSPECTOR AND THE AUTHORITY HAVING 1 GAMEWELL FCI INI-VGX TRANSPONDER VOICE GATEWAY 9 g W r Q <br /> JURISDICTION. ® 2 GAMEWELL FCI HPF-PS10 REMOTE POWER SUPPLY-10AMP Q e K W F <br /> o <br /> SCOPE OF WORK:REPLACEMEN S DD 0: <br /> 3 GAMEWELL FCI HPF-PS6 REMOTE POWER SUPPLY-7AMP <br /> T OF THE THE CURRENT SIMPLEX 4100 ADDRESSABLE FIRE ALARM SYSTEM AND VOICE m rc O <br /> a y 3 <br /> 11. LOCATE SMOKE DETECTORS A MINIMUM OF THREE(3)FEET FROM MECHANICAL DIFFUSERS.WALL-MOUNTED SMOKE DETECTORS m w w <br /> SHALL BE LOCATED A MAXIMUM OF 12"FROM CEILING. ❑F 20 GAMEWELL FCI MS-7ASF ADDRESSABLE PULL STATION EVACUATION DEVICES WITH A NEW UUKL ADDRESSABLE GAMEWELL/FCI FIRE ALARM SYSTEM WITH VOICE EVACUATION. <br /> O <br /> PHOTOELECTRIC SMOKE DETECTOR,W/MOUNTING BASE,BRIGHT SIMPLEX EQUIPMENT THAT WILL BE REPLACED INCLUDES:THE FIRE ALARM CONTROL PANEL,REMOTE ANNUNCIATOR, o-u.W a o <br /> 12. SMOKE DETECTORS USED FOR ELEVATOR RECALL SHALL BE INSTALLED WITHIN 21'OF THE ELEVATOR DOOR CENTERLINE(NFPA 72 55 GAMEWELL FCI ASD-PL3 WM300-6 WHITE ADDRESSABLE SMOKE DETECTORS,ADDRESSABLE MANUAL PULL-STATIONS,ADDRESSABLE MONITOR MODULES, <br /> 21.3.5)UNLESS OTHERWISE SHOWN. Oz REVISION RECORD <br /> 4 GAMEWELL FCI AMM-21F ADDRESSABLE DUAL MONITOR MODULE ADDRESSABLE RELAY MODULES,ADDRESSABLE CONTROL MODULES,ADDRESSABLE DUCT SMOKE DETECTORS,OCCUPANT <br /> 13. ALL MECHANICAL EQUIPMENT,SPRINKLER EQUIPMENT,AND DOOR HOLDERS ARE EXISTING AND NOT POWERED BY THE FIRE ALARM uN 2 GAMEWELL FCI AMM4F ADDRESSABLE MONITOR MODULE,SINGLE CIRCUIT NOTIFICATION DEVICES AND REMOTE POWER SUPPLIES. ALL EXISTING FLOW SWITCHES,TAMPER SWITCHES,PIVS,ELECTRIC DATE/DESCRIPTION <br /> SYSTEM. O <br /> 25 GAMEWELL FCI AOM-2RF ADDRESSABLE RELAY MODULE,2 FORM-C DRY CONTACTS DOORS,MAG-DOOR HOLDERS,FIRE/SMOKE DAMPERS,SMOKE CONTROL EVACUATION PANEL,CONVENTIONAL RELAYS,AND <br /> 14. THE FACP&ALL REMOTE POWER SUPPLIES WILL REQUIRE A DEDICATED 120VAC 20AMP CIRCUIT&A#12 TRUE EARTH GROUND AT ELEVATOR RECALL SYSTEMS SHALL REMAIN AND WILL BE TIED IN AS-IS.IN AREAS LACKING PROPER AUDIOVISUAL <br /> THE FACP.A NOTICE PLACED IN THE FACP SHALL DIRECT PERSONNEL TO THE LOCATION OF THE ELECTRICAL PANEL THAT IS 0 6 2 GAMEWELL FCI MMO-08F SIX-OUTPUT SIGNAL MODULE <br /> SUPPLYING DEDICATED POWER TO THE SYSTEM(NFPA72,SECTION 10.5.5.1).THE DEDICATED CIRCUIT BREAKER THAT SERVES THE CODE-COMPLIANT COVERAGE,NEW OCCUPANT NOTIFICATION DEVICES/CIRCUITS SHALL BE INSTALLED AS SHOWN. ALL <br /> FIRE ALARM SYSTEM SHALL BE LABELED AND SECURED AGAINST TAMPERING WITH A RED BREAKER LOCKOUT(NFPA72,SECTION o 5 GAMEWELL FCI DNR W/ASD-PL3R INTELLIGENT DUCT DETECTOR HOUSING,NON-RELAY W/ASD-PL3R EXISTING WIRING AND RACEWAYS WILL REMAIN AND BE REUSED. THE FIRE ALARM SYSTEM REPLACEMENT SHALL BE <br /> ® 5 GAMEWELL FCI RTS151KEY REMOTE TEST STATION WI SWITCH,ALARM&POWER LEDS,KEY PERFORMED IN A MANOR THAT WILL ELIMINATE THE NEED FOR FIRE WATCH. THE EXISTING SMOKE EVACUATION SYSTEM <br /> 15. POWER-LIMITED AND NONPOWER-LIMITED CIRCUIT WIRING MUST REMAIN SEPARATED IN THE CABINET.ALL POWER-LIMITED CIRCUIT RESET <br /> WIRING MUST REMAIN AT LEAST 0.25"AWAY FROM ANY NON-POWER LIMITED CIRCUIT WIRING.FURTHERMORE,ALL POWER-LIMITED sD INTELLIGENT SINGLE-ENDED REFLECTIVE IMAGING BEAM SMOKE SHALL BE TESTED BY A QUALIFIED 3RD PARTY SPECIAL INSPECTOR(BOB LONG W/UNITED BUILDING AND ENGINEERING <br /> AND NON-POWER LIMITED CIRCUIT WIRING MUST ENTER AND EXIT THE CABINET THROUGH DIFFERENT KNOCK OUTS AND/OR 2 GAMEWELL OSI-RI-Gw DETECTOR SERVICES,LLC)PRIOR TO THE FIRE FINAL ACCEPTANCE TEST.THE SMOKE CONTROL SPECIAL INSPECTION REPORT SHALL BE <br /> SEPARATE CONDUITS. WW� 2 GAMEWELL FCI INCLUDED SMOKE BEAM REFLECTOR PROVIDED TO THE AHJ PRIOR TO THE FIRE FINAL ACCEPTANCE TEST. BEFORE CONTACTING THE AUTHORITY HAVING <br /> 16. ALL FIRE ALARM CABLING SHALL BE ACCEPTABLE TO THE FIRE ALARM EQUIPMENT MANUFACTURER FOR THE INTENDED PURPOSE. 1 SYSTEM SENSOR SWLED STROBE,WALL,WHITE JURISDICTION(AHJ)FOR ACCEPTANCE TESTING,A THOROUGH PRE-TEST WILL BE CONDUCTED AND COMPLETED.THE <br /> CABLES USED IN VERTICAL RUNS SHALL BE TYPE FPLR.CABLE SPLICES OR TERMINATIONS SHALL BE MADE IN LISTED FITTINGS, sP 111 SYSTEM SENSOR SPSWL SPEAKERISTROBE WALL MOUNT,WHITE NFPA-72 COMPLETION FORM WILL BE PRESENTED TO THE AHJ PRIOR TO THE FIRE FINAL ACCEPTANCE TEST.ALL PERTINENT <br /> BOXES,ENCLOSURES,FIRE ALARM DEVICES,OR UTILIZATION EQUIPMENT.WHERE INSTALLED EXPOSED,CABLES SHALL BE <br /> ADEQUATELY SUPPORTED AND INSTALLED IN SUCH A WAY THAT PROTECTION AGAINST PHYSICAL DAMAGE IS AFFORDED BY 12 SYSTEM SENSOR SPSCWL SPEAKERISTROBE CEILING MOUNT,WHITE RECORD DOCUMENTS WILL BE STORED IN THE FIRE ALARM DOCUMENT CABINET AT THE FACP.THE SYSTEM DESIGN <br /> BUILDING CONSTRUCTION.WHERE EXPOSED CABLE IS LOCATED WITHIN 7 FT OF THE FLOOR,IT SHALL BE RUN IN RACEWAY. 7 SYSTEM SENSOR SCWLED STROBE,CEILING,WHITE <br /> ADHERES TO IBC,IFC,NFPA-70,NFPA-72 AND WA STATE REQUIREMENTS. <br /> 17. ALL SYSTEMS AND DEVICES SHALL BE INSTALLED AND TESTED PER THE MANUFACTURES LISTING AND THE AUTHORITY HAVING WP 1 SYSTEM SENSOR SRK STROBE,STANDARD CD,RED,OUTDOOR <br /> JURISDICTION(NFPA72 10.14.2.1).ALL INITIATING DEVICES AND DEVICES CONTAINING EOL'S SHALL HAVE A PHYSICAL LABEL Viz, <br /> IDENTIFYING THE DEVICE'S ADDRESS/END OF LINE RESISTOR. 1 1 SYSTEM SENSOR SSM24-10 ALARM BELL to-24VDC,RED PROJECT TEAM <br /> DOC 1 MEIR PRODUCTS BW-DOCBOX FIRE ALARM DOCUMENT BOX I5"W X ITH X4'D RED <br /> 18. INSTRUCTIONS FOR THE OPERATING,TESTING AND MAINTENANCE OF THE SYSTEM,ALONG WITH RECORD DRAWINGS OTHERWISE p DURACELL 12VDC12AH 12VDC 12Ah FACP BATTERY <br /> REFERRED TO AS("AS-BUILT")AND EQUIPMENT SPECIFICATIONS SHALL BE KEPT IN THE FIRE ALARM DOCUMENT CABINET NEXT TO OWNER FIRE ALARM CONTRACTOR SMOKE CONTROL SPECIAL INSPECTOR <br /> THE FACP(NFPA-72 10.18.2.3). 2 DURACELL 12VDC18AH 12VDC 18Ah AMPLIFIER BATTERY CITY OF EVERETT FIRE PROTECTION INC UNITED BUILDING & ENGINEERING, LLC <br /> 10 DURACELL 12VDC8AH 12VDC 8Ah POWER SUPPLY BATTERY 3201 SMITH AVENUE 17410 ASH WAY, Ste 8 1400 112th Ave SE, Ste 100 <br /> EVERETT, WA 98201 LYNNWOOD, WA 98037 EVERETT, WA 98004 <br /> 19. PRIOR TO CALLING FOR INSPECTION,THE INSTALLER SHALL PROVIDE DOCUMENTATION TO THE LOCAL AHJ STATING THAT THE EXISTING DEVICES/E CONTACT : RUSSELL DANCE CONTACT : DAVID MOW CONTACT : BOB LONG <br /> SYSTEM HAS BEEN INSTALLED,TESTED,EVALUATED AND CONFIRMED TO BE IN ACCORDANCE WITH ALL GOVERNING CODES AND THE PHONE : 425.257.8846 PHONE : 425.290.9600 PHONE : 425.591.4633 DATE: 03.25.24 <br /> APPROVED PLANS.A PRINTOUT SHALL BE PROVIDED TO THE AHJ SHOWING ALL DEVICES HAVE BEEN TESTED AND HOW EACH DEVICE AES EX AES 7707P-88-ULP-M ILL LISTED AES WIRELESS RADIO rdonce@everettwo.gov dovid@fpiseattle.com bob.long@unitedbes.com <br /> ANNUNCIATES AT THE FACP.THE FIRE ALARM SYSTEM INSTALLER SHALL COMPLETE AN NFPA-72 RECORD OF COMPLETION(NFPA-72 <br /> 10.18.2.1.1).THE COMPLETED RECORD OF COMPLETION SHALL BE PROVIDED TO THE AHJ INSPECTOR PRIOR TO REQUESTING A FIRE sc EX EXISTING EXISTING SMOKE CONTROL PANEL <br /> FINAL INSPECTION(NFPA-72 10.18.2.1.2.4). <br /> WF EX EXISTING EXISTING WATERFLOW SWITCH CODE INFO <br /> 20. THE MEANS OF SIGNAL TRANSMISSION TO THE REMOTE SUPERVISING STATION SHALL BE VIA THE FACP'S GATEWAY AND THE <br /> EXISTING UL LISTED AES WIRELESS RADIO COMMUNICATOR. EX EXISTING EXISTING VALVE TAMPER SUPERVISORY SWITCH Z <br /> EX EXISTING EXISTING MAGNETIC DOOR HOLDER AUTHORITY HAVING JURISDICTION:CITY OF EVERETT 0 LU C <br /> YEAR BUILDING WAS BUILT:2001 Q = N <br /> WD EX EXISTING EXISTING WON DOOR Z 00 <br /> VICINITY MAP CURRENT BUILDING CODE:IBC-2021 EDITION LJJ T <br /> LIE EX EX EXISTING MR-201IC/R DPDT MULTI-VOLTAGE CONTROL RELAY Z Q Q <br /> ®o EX EXISTING EXISTING DAMPER CURRENT FIRE CODE:IFC-2021 EDITION <br /> Kingdom f( I I BUILDING USE AND OCCUPANCY:(A) TRANSIT STATION-FULLY-SPRINKLED <br /> Jehovah'SW s <br /> ABBREVIATIONS USED IN THE DRAWINGS STANDARDS:2017 NFPA 70,2019 NFPA 72,CITY OF EVERETT STANDARDS F- <br /> Cn W <br /> < „ CLASSIFICATION OF SUPERVISING STATION:CENTRAL SUPERVISING STATION LU � <br /> W W <br /> C <br /> Funk.EverettQ Snohomish CounlyPUD® m a45 AFF ABOVE FINISHED FLOOR FSD FIRE/SMOKE DAMPER REMOTE SUPERVISING STATION:SECURITAS INC. W Cl LU <br /> D.R B-nyQ d AHJ AUTHORITY HAVING JURISDICTION HVAC HEATING VENTILATION AIR CONDITIONING PRIME FIRE ALARM CONTRACTOR:FIRE PROTECTION INC > <br /> Hewlll Ave W <br /> Everett i AIM ADDRESSABLE INPUT MODULE IBC INTERNATIONAL BUILDING CODE <br /> e's name ALT ALTERNATE RECALL (ELEVATOR) IFC INTERNATIONAL FIRE CODE PARCEL NUMBERS:00439074401300 <br /> gme chid-,Q Qimpreven:ent ALT AMPLIFIER (VOICE EVACUATION) L# SLC LOOP NUMBER <br /> Museum AOM ADDRESSABLE OUTPUT MODULE (RELAY) M MODULE (ADDRESSABLE) <br /> cd CANDELA MACH MACHINE <br /> Pxtlrc AVB PaciM Ave CONT. CONTINUE N# NAG CIRCUIT NUMBER <br /> E EVERETTIRAIN EMERGENCY COMMUNICATION VOICE EVACUATION SPEAKER dBA OUTPUT&SETTINGS <br /> 3 • .10r by. D DEVICE (ADDRESSABLE) NEC NATIONAL ELECTRIC CODE / <br /> g 32015MIIAV r onseanleEveren DC DUAL CIRCUIT NFPA NATIONAL FIRE PROTECTION AGENCY SHEET TITLE <br /> EVERETT,WA 982 DID DUCT DETECTOR PRIM. PRIMARY RECALL (ELEVATOR) <br /> D/H DOOR HOLDER (MAGNETIC) RPS REMOTE POWER SUPPLY <br /> 9eu DN DOWN RTU ROOF TOP UNIT Watt Setting dBA@loft FIRE ALARM <br /> = EC ELECTRICAL CONTRACTOR SC SMOKE CONTROL REPLACEMENT <br /> _ ELEV ELEVATOR SLC SIGNALING LINE CIRCUIT .25 Watt 78dBA <br /> aahs PROJECT DETAILS <br /> ,yle Park`o EOL END OF LINE RESISTOR STG STORAGE <br /> Brown Bear Car Wash EQUIP EQUIPMENT STR STAIRWELL .5 Watt 83cIBA <br /> PORT GARDNER Q - <br /> EVAC EMERGENCY VOICE EVACUATION T/S TAMPER SWITCH 1 Walt 86dBA <br /> FA EXISTING WET WET FIRESPRINKLER SYSTEM SHEET NUMBER <br /> 2 Walt 89dBA <br /> z FA FIRE ALARM W/F WATER-FLOW <br /> "°"°sue• FAA FIRE ALARM ANNUNCIATOR WP WEATHERPROOF All Speakers shall be set to 70vrms <br /> FACP FIRE ALARM CONTROL PANEL FA 0.0 <br />