Laserfiche WebLink
�E,-)O <br /> REMOTE POWER SUPPLY LOCATIONS # INSTALLATION KEY NOTES EXISTING CABLE AND WIRE LEGEND <br /> FIRE PROTECTION INC. <br /> RPS# LOCATION MODEL NUMBER LABEL QTY COLOR I COLOR-TYPE SIZE FUNCTION 17410 Ash Way,Ste 8 <br /> 10 A DEDICATED 120VAC POWER CIRCUITS IS REQUIRED FOR EACH FACP,REMOTE POWER <br /> RPS1 2ND FLOOR NORTH-ELEC RM 205 HPF-PS6 SUPPLY&AES RADIO.COORDINATE CONNECTIONS AND DEDICATED POWER WITH THE E.C. A 2 BLACK/ORANGE-TEN 16 ZONE Lynnwood,WA 98037 <br /> B 4 BLACK/ORANGE-TFN 16 ZONE (425)290-9600 <br /> RPS2 2ND FLOOR SOUTH-ELEC RM 221 HPF-PS6 ® THE EXISTING ADDRESSABLE FACP AND AMPLIFIER SHALL BE REPLACED WITH A NEW www.fpiseattle.com <br /> RPS3 4TH FLOOR NORTH-ELEC RM 405 HPF-PS6 ADDRESSABLE FACP AND AMPLIFIER. C 2 RED/BLUE-TFN 12 HORN/STROBE <br /> RPS4 4TH FLOOR SOUTH-ELEC RM 421 HPF-PS10 ® THE EXISTING FA REMOTE POWER SUPPLY SHALL BE REPLACED WITH A NEW FA REMOTE D 4 (2)RED I(2)BLUE-THEN 12 HORN/STROBE LOOP <br /> RPS5 BASEMENT-ELEC RM 001 HPF-PS10 POWERSUPPLY. E 2 BROWN/YELLOW-THHN 14 DOOR HOLDERS <br /> 40 THE EXISTING FIRE ALARM REMOTE ANNUNCIATOR SHALL BE REPLACED WITH A NEW F 2 BROWN YELLOW-THHN 14 FAN SHUTDOWN <br /> REMOTE ANNUNCIATOR. 1 WEST PENN D975 18 <br /> H LCD ANNUNCIATOR <br /> DEVICE IDENTIFICATION LEGEND THE EXISTING CONVENTIONAL SMOKE BEAM DETECTOR SHALL BE REPLACED WITH A NEW 2 REDIBLACK-THHN 14 NFPA <br /> ADDRESSABLE SMOKE BEAM DETECTOR. J 1 TWISTED SHIELD-PAIR 14 SPEAKER <br /> SPEAKER/STROBES 000805173 <br /> K 2 TWISTED/SHIELD-PAIR 14 SPEAKER LOOP <br /> AMP 2•Si•08-PANEL-SPKR CRKT#•DEVICE# ® THE EXISTING ADDRESSABLE DUCT SMOKE DETECTOR SHALL BE REPLACED WITH A NEW <br /> FACP•N1.05 -PANEL•NAC CRKT#•DEVICE# ADDRESSABLE DUCT SMOKE DETECTOR. L 2 YELLOW-THHN 14 ELEVATOR RECALL <br /> ROY L CATS <br /> 15cd CANDELA SETTING N 2 RED/BLACK THHN 14 NAC TRIGGER <br /> 0 THE EXISTING DUCT DETECTOR REMOTE TEST SWITCH SHALL BE REPLACED WITH A NEW pOTECT <br /> O.Sw WATT SETTING(70vrm) P 2 REDIBLACK-THHN 14 24VDC POWER Q4,Q y <br /> REMOTE TEST SWITCH. x0 <br /> Q 2 BLUE/BLUE-THHN 14 SMOKE CONTROL 4 m <br /> SLC DEVICES 8Q THE EXISTING DEVICE WILL BE REMOVED,THE EXISTING CIRCUITS WILL BE WIRED THROUGH I w � <br /> 2 BLUE/WHITE-TFN 16 <br /> L1•D001 SLC#•DEVICE# EXTENDED TO THE NEW DEVICE LOCATION AS SHOWN. t <br /> } R REMOTE LED wI TEST SWITCH r NFPA' <br /> D=DEVICE 2 PINK-TFN 16 b <br /> M=MODULE ® NEW OCCUPANT NOTIFICATION DEVICE WILL BE INSTALLED AS SHOWN TO PROVIDE CODE-COMPLIANT COVERAGE. S 2 PURPLE/WHITE-THHN 14 SMOKE I FIRE DAMPERS CFPS <br /> 10 THE EXISTING RELAY WILL REMAIN AND BE REUSED.THE EXISTING ADDRESSABLE FIRE V 2 REDIBLACK-THHN 14 RESETTABLE POWER #1473 <br /> ALARM RELAY SHALL BE REPLACED WITH A NEW ADDRESSABLE FIRE ALARM RELAY.THE FIRE X 1 WEST PENN D975 18 MAPNET DATA-SLC <br /> ALARM SYSTEM ONLY PROVIDES DRY CONTACTS ONLY FOR THE EXISTING SMOKE CONTROL SPEAKER CIRCUIT WIRING REQUIREMENTS:USE TWISTED,SHIELDED PAIR.MAKE SURE THE SHIELD IS RUN CONTINUOUSLY <br /> PANEL,DOOR HOLDERS,WON DOOR,AND FIREISMOKE DAMPERS.POWER IS NOT PROVIDED THROUGH THE SPEAKER CIRCUITS WITH NO SEGMENTS OF THE SHIELD LEFT FLOATING.DO NOT TIE THE SHIELD TO THE a <br /> BY THE FA SYSTEM. CONDUIT OR THE JUNCTION BOXES IN THE FIELD.TERMINATE THE DRAIN WIRE BACK AT THE PANEL'S LOCATION.SEE <br /> w <br /> 11 THE EXISTING SMOKE CONTROL SYSTEM IS NOT PART OF THE FIRE ALARM SYSTEM.THE FIRE INSTALLATION MANUAL FOR DETAILS. <br /> ALARM SYSTEM PROVIDES A DRY CONTACT THAT WILL ACTIVATE ON ANY GENERAL FIRE w n y <br /> ALARM SIGNAL. ALL EXISTING WIRE SHOULD BE TAGGED AND IDENTIFIED WITH ALL ZONE NUMBER,SIGNAL CIRCUIT NUMBERS AND <br /> ANNUNCIATOR NUMBERS w z <br /> O u (0 <br /> `r J f(7� <br /> p o <br /> a m w O o a <br /> H y W�W <br /> �uoLL`v,o 3 <br /> z>-3 dw s <br /> Q; W�xa o <br /> aV Ww^bo <br /> czw o <br /> REVISION RECORD <br /> NEW SHOWN IJ ITS RE N RED I <br /> DATE/DESCRIPTION <br /> A.TOPIV <br /> DN TO FACP IN SLAB:DJX <br /> X F ENTRY ENTRY F <br /> _ _ _ _ _ _ _ _ _ _ _ _- 0 _ _ _ _ _ fit_- _ _ -_ _ 33 <br /> --� 6SF(A)•SPK-1.14 pl AIM F L2,M001 MEN RPSS•Ni•11 - - - - - - - - - - --- FFICE - - Ll-MO34- - Li•M036 % <br /> RECYCLE -IAI 6-SF(A)•SPK-1.08 <br /> RPSS•N1.12 30cd <br /> 1 01 X 75od 2.09 <br /> i 5cd 109 10 0.5 I I 0 I BAGGAGE CKK 75cd <br /> o Sw 0 CJX CJX <br /> X � 120 O,SW <br /> F dS (1 L1• 11 S <br /> F A.SP 1.1ghl ��0 C4z--z[ !� <br /> _ L2•M004- 5 x_ 0 _-_-_- _-_-_-_ X 6SF(A)•SPK- ___ -___ _-_-_ _ -_ A.5 <br /> u 2J Nx <br /> i 3 w RP85•N2.O6 CKX <br /> L1A012 <br /> S NS' JX I 6-SF(A)•SPK41.19 CJ 0.5 A122RM S <br /> 6 S A PK-1.05 dS L2.003 ()•SPK-1.17 SP RP55•Ni•14- R SS•N2.OS 6-SF <br /> 14, <br /> C ST. P N1.10 110cd B G G <br /> WOMEN 110cd -� <br /> q <br /> J 130cd I 1w RPSS•N2.OB OCA DHPX: FACT <br /> 6-SF(A)•SPK-2.02 1 7_ _-_ _ _ 102 .w-_-_-_-_ _ _-_- _ _ ___- _-iw_ i5od 0 B <br /> RPS5•N3•16E0L4.7k I O.Sw L1•M039 <br /> 103 75rd C1017 CJ 119 L1•D010 11 <br /> 0.5w 07 0 <br /> 6-SF(A)•SPK-2.01 S KK 9 RPSS•N•07FAL sc RL noM FAA D <br /> CJ RPS5•N3.01 X L CKERS CJX iSrA L•D013 EX O4 DH <br /> L2•D002 BREAK RM S a 35 Li M037 <br /> o5w is N OFFICE CKK: TO ACP 123A F <br /> -2.03 C:DN -116 - ----- ICK ETING 130 _ -HALL_ UP:CKX -- _-_ _ -_ _ N6-SF(A)•SPK-1.0 � I"� <br /> II RPS5• Ot <br /> ( RPS5•N109 � RPSS•N2.10 <br /> 8-SF(A)•SPK-2-06 1 d S U GE R o RPS&WN- E <br /> 1 PK-1.01 15cd <br /> RPS5•N3.12 106 CKK I 110cd <br /> o a DN 1 d Li•D009 X <br /> m I SP 0. O RPSS•N2.01 O.Sw � <br /> E 2 GREAT HALL 15cd ®° C'° C F _i <br /> C ILD °� 6-SF(A)•SPK-2.15 1 100 I O.Sw y 1•M038 <br /> 'P F )•SPK-1 osT DATE: 03.25.24 <br /> R Al I g� FOUNC- <br /> S _ 15cd _ _ _ _ _ _ _ 5•N2 _ _ _ 138 CKX __ _. <br /> 10 0.5w S � 131 �6 <br /> KI�C OH N O J L2•D004 0�2 33 1 a 6 <br /> 6 F(A)•SPK-2.07 5w CJ CJX: ( AI SP <br /> RPS5•113.11 6 )•SPK-2.13 IN SLAB EC/ EL 1 6SFA)•SPK-1.10 <br /> i5cd RPS•N3.OS I 105 CJX CKX w 15cd ® RPS N2.11 <br /> j C O. m CJ ° 3C =0.25w 30cd I <br /> 0.25w u I 15c CKK Z <br /> j 6S •SNJI.-��08 6-SF(A)•SPK-2.05 _ � O.Sw - TO I 0.5w qq <br /> r��} RPS5•N3.10 _ _-_ _ J6_ _ _- 6-SF(A)•SPK-1.04 J L l E 0LLI <br /> 6-` PK-2.0 15cd 6-SF(A)•SPK-1.20 EOL 47k�_-_ RPSS•N2.04 - _- -_ -_-_ - CKX _-_-_ -_� Q = CD <br /> PSS•N3.09� I CJ ';J UP: N <br /> 15cd 0.25w 0.5w SP RPS5•N1.15 EOL 4.7k 110cd PRFP T.C.S.C. ' Z <br /> 0.25w SP I L 6-SFtA)•SPK-•1 iwOcd 1w Q 136 �T I Q0 <br /> �3 LU O) <br /> dS RPS5 3.07 C SP > <br /> ESTIBU E J Sp 15cd DK 6-SF(A)•SPK-1.12 DK Z Q Q <br /> 100 0.25w PS5•N2.13 <br /> CLASSROOM 1 CLA SROOM 2 x x3. _ Q Z <br /> -- - OS- 6 (A)•SPK-2.10 101 O p 6-SF(A)•SPK-2.11 D -- +1i=BkEN• - - -T-CJ - - - - - - S - 0.5w a RPPSS6•N2•iSe4 OL 4.7k F ~ <br /> CJ 04 R 5•N3.08 RPSS•N3.O6 Q Q' I i 6SF(A)•SPK-1.11 75cd W <br /> 15 951d d RPS5•N2.12 (_�-E X O.Sw cn <br /> w 0. w 1w 30W 140 x <br /> 6-SF(A)•SPK-2•16 EOL 47k I 0.5w I W - W <br /> RPS5•N3-02 L2•M007 Ll-M032 G <br /> STO. I 75W F ENTRY ENTRY F = L1•M031 X . W m W <br /> 1olA O.6w 5 > <br /> LLLF G SHEET TITLE <br /> FIRE ALARM 1ST FLOOR <br /> 9 8.8 8 7.8 7 6.6 6 5 4 3 2.3 2.2 2 1.7 1.2 1 REPLACEMENT <br /> SHEET NUMBER <br /> FIRE ALARM REPLACEMENT - 1ST FLOOR PLAN <br /> SCALE:1/8"=1' N <br /> G'l 5' 20• FA 2.0 <br />