Laserfiche WebLink
�E,-)O <br /> REMOTE POWER SUPPLY LOCATIONS # INSTALLATION KEY NOTES EXISTING CABLE AND WIRE LEGEND <br /> FIRE PROTECTION INC. <br /> RPS# LOCATION MODEL NUMBER LABEL QTY COLOR I COLOR-TYPE SIZE FUNCTION 17410 Ash Way,Ste 8 <br /> 10 A DEDICATED 120VAC POWER CIRCUITS IS REQUIRED FOR EACH FACP,REMOTE POWER <br /> RPS1 2ND FLOOR NORTH-ELEC RM 205 HPF-PS6 SUPPLY&AES RADIO.COORDINATE CONNECTIONS AND DEDICATED POWER WITH THE E.C. A 2 BLACK/ORANGE-TFN 16 ZONE Lynnwood,WA 98037 <br /> B 4 BLACK/ORANGE-TFN 16 ZONE (425)290-9600 <br /> RPS2 2ND FLOOR SOUTH-ELEC RM 221 HPF-PS6 ® THE EXISTING ADDRESSABLE FACP AND AMPLIFIER SHALL BE REPLACED WITH A NEW www.fpiseattle.com <br /> RPS3 4TH FLOOR NORTH-ELEC RM 405 HPF-PS6 ADDRESSABLE FACP AND AMPLIFIER. C 2 RED/BLUE-TFN 12 HORN/STROBE <br /> RPS4 4TH FLOOR SOUTH-ELEC RM 421 HPF-PS10 ® THE EXISTING FA REMOTE POWER SUPPLY SHALL BE REPLACED WITH A NEW FA REMOTE D 4 (2)RED I(2)BLUE-THHN 12 HORN/STROBE LOOP <br /> RPS5 BASEMENT-ELEC RM 001 HPF-PS10 POWERSUPPLY. E 2 BROWN/YELLOW-THHN 14 DOOR HOLDERS <br /> (1) THE EXISTING FIRE ALARM REMOTE ANNUNCIATOR SHALL BE REPLACED WITH A NEW F 2 BROWN YELLOW-THHN 14 FAN SHUTDOWN <br /> REMOTE ANNUNCIATOR. 1 WEST PENN D975 18 <br /> H LCD ANNUNCIATOR <br /> DEVICE IDENTIFICATION LEGEND THE EXISTING CONVENTIONAL SMOKE BEAM DETECTOR SHALL BE REPLACED WITH A NEW 2 RED/BLACK-THHN 14 NFPA <br /> ADDRESSABLE SMOKE BEAM DETECTOR. J 1 TWISTED SHIELD-PAIR 14 SPEAKER <br /> SPEAKER/STROBES 000805173 <br /> K 2 TWISTED/SHIELD-PAIR 14 SPEAKER LOOP <br /> AMP 2•Si•08-PANEL-SPKR CRKT#•DEVICE# (V THE EXISTING ADDRESSABLE DUCT SMOKE DETECTOR SHALL BE REPLACED WITH A NEW <br /> FACP•Nl-05 -PANEL•NAC CRKT#•DEVICE# ADDRESSABLE DUCT SMOKE DETECTOR. L 2 YELLOW-THHN 14 ELEVATOR RECALL <br /> ROY L CATS <br /> 15cd CANDELA SETTING N 2 RED/BLACK THHN 14 NAC TRIGGER <br /> 0 THE EXISTING DUCT DETECTOR REMOTE TEST SWITCH SHALL BE REPLACED WITH A NEW pOTECT <br /> O.Sw WATT SETTING(70wm) P 2 RED/BLACK-THHN 14 24VDC POWER Q4,Q X0 <br /> REMOTE TEST SWITCH. <br /> Q 2 BLUE/BLUE-THHN 14 SMOKE CONTROL 4 m <br /> SLC DEVICES 8Q THE EXISTING DEVICE WILL BE REMOVED,THE EXISTING CIRCUITS WILL BE WIRED THROUGH I w � <br /> 2 BLUE/WHITE-TFN 16 <br /> L1•DO01 SLC#•DEVICE# EXTENDED TO THE NEW DEVICE LOCATION AS SHOWN. t <br /> } R REMOTE LED wI TEST SWITCH r NFPA' <br /> D=DEVICE 2 PINK-TFN 16 b�J y0 <br /> M=MODULE ® NEW OCCUPANT NOTIFICATION DEVICE WILL BE INSTALLED AS SHOWN TO PROVIDE CODE-COMPLIANT COVERAGE. S 2 PURPLE/WHITE-THHN 14 SMOKE I FIRE DAMPERS CFPS <br /> 10 THE EXISTING RELAY WILL REMAIN AND BE REUSED.THE EXISTING ADDRESSABLE FIRE V 2 RED/BLACK-THHN 14 RESETTABLE POWER #1473 <br /> ALARM RELAY SHALL BE REPLACED WITH A NEW ADDRESSABLE FIRE ALARM RELAY.THE FIRE X 1 WEST PENN D975 18 MAPNET DATA-SLC <br /> ALARM SYSTEM ONLY PROVIDES DRY CONTACTS ONLY FOR THE EXISTING SMOKE CONTROL SPEAKER CIRCUIT WIRING REQUIREMENTS:USE TWISTED,SHIELDED PAIR.MAKE SURE THE SHIELD IS RUN CONTINUOUSLY <br /> PANEL,DOOR HOLDERS,WON DOOR,AND FIRE/SMOKE DAMPERS.POWER IS NOT PROVIDED THROUGH THE SPEAKER CIRCUITS WITH NO SEGMENTS OF THE SHIELD LEFT FLOATING.DO NOT TIE THE SHIELD TO THE a <br /> BY THE FA SYSTEM. CONDUIT OR THE JUNCTION BOXES IN THE FIELD.TERMINATE THE DRAIN WIRE BACK AT THE PANEL'S LOCATION.SEE <br /> w <br /> 11 THE EXISTING SMOKE CONTROL SYSTEM IS NOT PART OF THE FIRE ALARM SYSTEM.THE FIRE INSTALLATION MANUAL FOR DETAILS. <br /> ALARM SYSTEM PROVIDES A DRY CONTACT THAT WILL ACTIVATE ON ANY GENERAL FIRE <br /> ALARM SIGNAL. ALL EXISTING WIRE SHOULD BE TAGGED AND IDENTIFIED WITH ALL ZONE NUMBER,SIGNAL CIRCUIT NUMBERS AND <br /> ANNUNCIATOR NUMBERS w z <br /> O u (0 <br /> p 4 <br /> a m K O N o a <br /> H y W W <br /> �uoLL`v,o 3 <br /> z>-3 uw s <br /> F-W�x o <br /> NEW CIRCUITS ARE c W>a-o > <br /> Ij o <br /> SHOWN IN RED <br /> REVISION RECORD <br /> DATE/DESCRIPTION <br /> S S <br /> Ll-D032 X Ll-DO31 % L1•D63D <br /> I <br /> II rF(BRP5.12_-_-_-_-_-_-_ _-_1- -___ _-_-_-_-_-_-_ __-___-_-_-_ S4•N2.01 <br /> tr <br /> 75M <br /> tr <br /> 6-SF(B)•SPK5•6 0.5w <br /> RPS3•Nl-02 CJ 6SF(B)•SPK5.11 <br /> 75cd <br /> - <br /> STAFF LUNCH R I CONF RPS4•N2.02 ADMIN <br /> 418 417 15od d5 419 <br /> iw _ 6-SF(B)•SPK-3.07 -L <br /> 6-SF(B)•SPK-5.17EOL47k _ _ _ _ _ __ _ _ _ _ _ _ ___ _______ _ _ _ A..JI <br /> } OPEN OFFICE dS SP OP N OFFICE CJPX RPS4•Ni•07 <br /> RP83•Nl-Ol SERVE RY 75cd <br /> 75cd <br /> iw C 400 1. I I I CJ 6SF(B)•SPK-SF( <br /> J RPS4•N2.03 <br /> 6SF(B)•SPK-3.OS 15cd <br /> RPS4•N1.O& X 0.5w <br /> -- --I-- ---- I -- ---- I ----- - ----- 3ocd ---------------- I --- -�G. UPIOF <br /> Je - - --� <br /> ` 0.5w JNP T FRCP - -I--I---- 6y3F(B)•SPKS•09 CJ CJN I B <br /> DX 6-SF(B)•SPK-3.12 EOL 47k )•S 3.09 h <br /> GSF(B)•PK-5.15 JB T % 1.09 MULTI-PURPOSE RPS4•N2o0044 dS <br /> RP$3•Nl-03 1` L2•DO23 CORR. �•�� % 15� CJ x 400 i 0.5w MANAG R <br /> 110cd 0.5w S JB S O.Sw Ic 2RX 416 <br /> 1w CJ SP L2•MO14 CJP' 407 CJPRX JB dS I <br /> PRX JB F JB JB - S S -SF(B)•SPK-3.01 <br /> X - _ _ _ J -_ _ 61 RPS4•N1.01 J6 !J6 <br /> } - - - CJPRx' -�hB649-- -- X Li•D028 E <br /> ® D DX CX 15cd <br /> L2•M015-M016 N O.Sw R:TO DUCT DET <br /> C2NPx <br /> WF e L4 N.RISER+ •10 S a P33 D/ <br /> wF _ S4•N1.10 <br /> F:TO FAN D� % '.1EN 30cd L2•DO - � ,0. OPEN OFFICE <br /> _IS <br /> CORR. CJP2RX <br /> SHUTDOWN Qc N.DUCTDET 401 pU,.S5W CJPX RPS4• 1EOL4.7k __ DATE: 03.25.24 <br /> i2•D024 S SP WOMLIV dS J NC _-_ 4 _ _-_-_-_- __-_ _-_ _ 15cd r- S Lt•D025 - -- Li•DO34 <br /> _-I-_- L2.M017 nan _ I - - 6SF(B)•SPK- ,� I I D B \� <br /> HVAC SHUTDOWN 6-$F B•SPK-3.06 C2NPX C2NPX O s S DUCT DET TO AN <br /> CJ RPS4•N1.11 EL 1 I) 1 3 <br /> 30cd C MM RPS4•Ni•O6 6-SF(B) PK-3.02 JB S O� UT OWN <br /> 0.. 06 CJPX 95W I I R •N1.02 +- RPS4 <br /> Li•M044 <br /> .0 Scd L�D623 X <br /> HVAC SHUTDO �J <br /> LILLw Z <br /> ___- _�LST-_ _ _ _ _ _ _ _ X -_ 6-SF(B)•SPK-5.08 -_- � E O W OPEN OFFICE RPsml-04 WON DR - - - - - - -- 6 - CJP2R% CJPX JB R0.d' PRX � = O <br /> 420 15cd 6SF(B)•SPK- 05 Li•D027 LI-DO26 RPS•Ni•04 <br /> 0.25w N S4•N 05 S gyp% CORR. S 15cd CORR. L1�024 S X SP 1w Ll-D033 Z 00 <br /> A PEALS 1 c04 <br /> d X 410 X 0.5w� CJPX 420 a 6-SF(BpSPK-3.03 © SW DUCT DET U) W Q <br /> �21 C�3 1ST AID o 5w w RPS4•N1.03 de 15dcu Ll-MO43 > <br /> CJ 6-SF(B)• R5.01 6-SF(B•PK-5.03422 J6 OSw P2Rx P HVAC SHUTDOWN Z_ a <br /> _ _ _ _ _- - Q = <br /> 15cd JN JN _ F:TO FAN <br /> - ---------_ �- i --�--_ .25 0.25w _�_-_-_-_-_---------_�- -_�----_- CJ CJ -v 6-SF(B)•SPK-5.07 SHUTDOWN cn W <br /> % I CENTER I I _ B•SPK •06 30Sd 2•�6 <br /> sWI CAREER DVLP IR <br /> CJ WIN 6-SF(B)•SPK5• PS4 N2'08�EOL 4.7k d 4.2.07 0.5w LLI W <br /> 1 CONE O > <br /> 6SF(B)•SPK-5.02 SP RPS3•N1.09 EO 4.7k 110W <br /> DK •NI.07 75cd 1w O w 414 E 5 Lu M LII <br /> _ _ __-_-_-�_ -_ _ _�_ _ _ _ _ 1 _ _ �- 0.5w _T- _ _ _ _ _ _ _ _ _�_ ___ -_ _ __ ' _�O _ _- -_� _ <br /> 6-SF(B)•SPK-5.13 I OFFICE O w OFFICE I I I I 415 I CJ I LLI <br /> RPS3•N1-05 424 424b <br /> lw5cd <br /> _-_r___-_-_-_-_-_-_-_-_r_-_ <br /> SHEET TITLE <br /> 818 /I\ �7 6!6 �5 �4 �3 213 212 2� 117 2 <br /> FIRE ALARM <br /> REPLACEMENT <br /> 4TH FLOOR <br /> SHEET NUMBER <br /> FIRE ALARM REPLACEMENT - 4TH FLOOR PLAN <br /> SCALE:1/8"=1' N <br /> 5 FA 5.0 <br />