(oodWo@ ksg Shearwalls Whitkanack Shop.wsw Jain. 23, 2022 20:07:01 <br />SHEAR RESULTS (flexible seismic desian) <br />N-S <br />W <br />For <br />ASD <br />Shear Force [pig <br />Asp -Cub <br />Allowable <br />Shear [plf] <br />Resp. <br />Shearlines <br />Gp <br />Dir <br />v <br />vmaxivft <br />V <br />PbSI <br />Int Ext Int <br />Ext Co <br />C Cmb <br />V abs] <br />Ratio <br />Line 1 <br />Level 2 <br />Ln_, Lev2 <br />= <br />Bcth <br />16.9 <br />- <br />605 <br />- i.0 - <br />250 - <br />25C <br />F,240 <br />0.05 <br />Level 1 <br />:,n1, Levl <br />- <br />Both <br />- <br />- <br />724 <br />- - - <br />- - <br />- <br />3172; <br />- <br />Wall 1-1 <br />_ <br />Both <br />- <br />- <br />724 <br />- 1.0 - <br />260 - <br />- <br />3172 <br />- <br />Seg. 1 <br />- <br />Both <br />59.3 <br />0.0 <br />534 <br />- 1.0 - <br />260 - <br />260 <br />2340 <br />0.23W <br />Sea. 2 <br />- <br />Bcth <br />0.0 <br />0.0 <br />C <br />- 1.0 - <br />260 - <br />260 <br />- <br />- W <br />Seg. 3 <br />- <br />Both <br />47.5 <br />0.0 <br />190 <br />- SO - <br />20a - <br />206 <br />832 <br />0.231f <br />Line 2 <br />Level: 2 <br />Ln2, Lev2 <br />- <br />Both <br />- <br />- <br />&3G <br />- - - <br />- - <br />- <br />41E0 <br />- <br />Wall 2-1 <br />- <br />Bet), <br />- <br />- <br />430 <br />- 1.0 - <br />250 - <br />- <br />41EO <br />- <br />Seg. 1 <br />- <br />Loth <br />2E.9 <br />0.0 <br />148 <br />- l.0 <br />260 - <br />260 <br />1430 <br />0.10 <br />Seg. 2 <br />- <br />Both <br />26.5 <br />0.0 <br />134 <br />- l.0 - <br />260 - <br />260 <br />1300 <br />0.10 <br />Seg. 3 <br />- <br />Broth <br />2E.9 <br />0.0 <br />148 <br />- 1.0 - <br />260 - <br />260 <br />1430 <br />0.10 <br />Level 1 <br />:,n2, Levl <br />= <br />Beth <br />31.2 <br />- <br />749 <br />- 1.0 - <br />260 - <br />260 <br />E200 <br />0.128; <br />E-W <br />W <br />For <br />ASD <br />Shear Force <br />[plf] <br />Asp -Cub <br />Allowable Shear [pM <br />Resp. <br />Shearllnes <br />Gg <br />Dir <br />v <br />vmaxdvft <br />V Obs] <br />Int. Ext Int <br />Ext Co <br />C Cmb <br />V bs <br />Ratio <br />Line A <br />Level 2 <br />LnA, Le-r2 <br />- <br />Seth <br />- <br />- <br />4'4 <br />- - - <br />- - <br />- <br />4056 <br />- <br />Wall a-1 <br />1 <br />both <br />- <br />- <br />- 1.0 - <br />260 - <br />- <br />4056 <br />- <br />Seg. 1 <br />- <br />both <br />26.6 <br />0.0 <br />372 <br />- 1.0 - <br />260 - <br />260 <br />3640 <br />0.1011 <br />Seg. 2 <br />- <br />both <br />21.3 <br />0.0 <br />43 <br />- .80 - <br />209 - <br />208 <br />416 <br />0.10e? <br />Line B <br />an3, Lev2 <br />bc,h <br />- <br />- <br />414 <br />- - - <br />- - <br />- <br />4485 <br />- <br />Wall a-1 <br />1 <br />&c_h <br />- <br />- <br />414 <br />- 1.0 - <br />260 - <br />- <br />4495 <br />Seg. 1 <br />- <br />Seth <br />24.0 <br />0.0 <br />312 <br />- 1.0 <br />260 - <br />260 <br />3380 <br />0.09W <br />Seg. 7. <br />- <br />both <br />24.0 <br />0.0 <br />102 <br />- 1.0 - <br />260 <br />260 <br />1105 <br />0.09'vt <br />Level 1 <br />LnB, Levl <br />1 <br />both <br />73.3 <br />- <br />1457 <br />- 1.0 - <br />260 - <br />260 <br />5200 <br />0.22W <br />Legend: <br />W GP - Wall design group defined in Sheathing and Framing Materials tables, where it shows associated Standard Wall. "A'Means that this wall is critical for <br />afl walls in the Standard Wall group. <br />For Dir- Direction of seismic force along shearline. <br />v - Design shear force on segment = ASD-factored shear force per unit length offull-height sheathing (FH1S) <br />vmax/vft - Perforated walls: Collector and in -plane anchorage force as per SDPWS eqn. 4.3-9 = VIFMS/Co. FH1S is factored for narrow segments as per <br />4.3.4.3 <br />Force -transfer walls: Shear force in piers above and below either openings or piers beside opening(s). Aspect ratio factor does not apply to these piers. <br />V - ASD factored shear force. For shearine: total shearline force. For walla total of all segments on wall. For segment., force on segment <br />AsplCub - For wall: unblocked structural wood panel factor Cub from SDPWS 4.3.3.2. For segment or force -transfer pier. Aspect ratio adjustment from <br />SDPWS 4.3.3.4.1 <br />Int - Unit sheer capacity of interior sheathing; Ext -Unit shear capacity of exterior sheathing. For wall: Unfactorad. For segment: Include Cub factor and <br />aspect ratio adjustments. <br />Co - Adjustment factor for perforated walls from SDPWS Table 4.3.3.5. <br />C - Sheathing combination rule, A = Add capacities, S = Strongest side or twice weakest, G = Stifness-based using SDPWS 4.3 3. <br />Cmb - Combined interior and exterior unit shear capacity including perforated wall factor Co. <br />_ V- Total factored shear eapaci of shearline, we _ _ ........... <br />ft orsemerrt: __.___.___.__._._.................... <br />......... <br />Crit Resp - Response ratio = vlCmb = design shear forcelunit shear capacity. "W" indicates that the wind design criterion was critical in selecting wall. <br />Notes: <br />Refer to Elevation View diagrams for individual level for uplift anchorage force t for perforated walls given by SDPWS 4.3.6.4.2.4. <br />10 <br />
The URL can be used to link to this page
Your browser does not support the video tag.