Laserfiche WebLink
POLYGLASSO" G2 BASE <br /> APPLICATION INSTRUCTIONS <br /> Polygls G2 Base is intended to be used as a base sheet in new or re-roof applications. Polygloss G2 Base may be <br /> appliedas directly to non-combustible substrates. Polygloss G2 Base requires the installation of a compatible additional <br /> membrane(s) to complete roofing system. <br /> • Apply over clean, dry, dust and debrisfree substrates. Prime concrete decks prior to application with Polyglass 10 <br /> Asphalt Primer. <br /> m • When reroofing, remove all prior roofing materials down to a clean debris-free substrate and properly close off all <br /> • <br /> abandoned roof penetrations. <br /> • Concrete or steel decks shall be designed with proper expansion devices. <br /> • Wood decks shall have all joints blocked or properly supported as required by Building Design and Code. <br /> • Ensure the fire rating of the assembly over any combustible substrate. <br /> • Ensure the installation of Polyglass G2 Base does not prevent the ventilation of existing construction. <br /> While installing Polyglass G2 Base: <br /> 1. Start at the low point of the roof. <br /> 2. Unroll the material and allow to relax. <br /> 3. Position successive rolls providing a minimum 6" end lap and 3"side lop. <br /> • Polyglass G2 Base can be used as a base sheet in flashing applications. Check project details for proper <br /> installation requirements. <br /> MANUFACTURING FACILITIES <br /> • Fernley, NV <br /> • Haieton, PA <br /> • Winter Hove^ FL <br /> CORPORATE HEADQUARTERS <br /> Polyglass U.S.A., Inc. <br /> 1 1 1 I West Newport Center Drive <br /> Deerfield Beach, FL 33442 <br /> www.polyglass.com <br /> General Line: (888) 410-1375 <br /> (954) 233-1330 <br /> Customer Service: (800) 222-9782 <br /> Technical Service: (866) 802-8017 <br /> Questions?technicol@polyglass.com <br /> Product Disclaimer. Unless otherwise incorporated into or ppoort of a supplemental manufacturer's warranty, Polyglass warrants its productfs) <br /> against manufacturing defects in its product that directly results in teokage for a period of I year. <br /> Refer to material safety data sheet IMSDS)for specific data and handling of our products.Alt data furnished refers to standard production and is given <br /> in good faith vvPhin the applicable monurtacruring and testing tolerances. <br /> Polygloss U.S.A., Inc.,reserves the right to improve and chopge its products at any time mihout prior notice.Polyglass U.S.A. Inc.cannot be held <br /> responsible for the use of its products under conditions beyond its own control. for most current product data and worranty information,visit wvVw. <br /> polygbss.com <br /> ROOFING.AND WATERPROOFING SYSTEMS <br /> 41 IA AI <br /> mmuff <br /> 6 n o v w <br /> 1-800-222-9782 <br /> Copyrtg."•*Q20'4 by Polygiass U.S.A..Inc omd a€eight.,aye eayrne' www.pofygI ass.eexm <br /> UK—DoW.07114•DocR tblmkms G2 lase <br />