My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1001 N BROADWAY 2020 EVCC 2025-10-03
>
Address Records
>
N BROADWAY
>
1001
>
EVCC
>
1001 N BROADWAY 2020 EVCC 2025-10-03
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/3/2025 11:23:53 AM
Creation date
9/26/2025 11:35:03 AM
Metadata
Fields
Template:
Address Document
Street Name
N BROADWAY
Street Number
1001
Tenant Name
EVCC
Year
2020
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
327
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
deflections without breaking, as well as notes for fire sprinklers with special detailing requirements <br /> meeting the exception. IBC 404.6, 712.1.7. <br /> 5. On Sheet 1/A6.19, it appears that the handrail extensions from the bottom riser do not slope. Please <br /> revise as required to a sloping configuration. IBC 1014.6. <br /> 6. On Sheet A6.011, it appears that notes for the two-way communication system at the proposed <br /> elevator appear to be missing. Please clarify or revise drawings as required. IBC 1009.8. <br /> STRUCTURAL <br /> 7. On Sheets 54.01, 54.02, 54.03,gusset plate length dimensions for welding to the braced frame beams <br /> and columns appear to be missing. Work points have been indicated, but there does not appear to <br /> be a schedule or method to determine if the gusset plate weld length to columns and beam <br /> members are corresponding to the provided design lengths in the permit design calculations. Please <br /> indicate where such dimensions can be found on the plans. IBC 107.2.1. <br /> 8. On 1/53.03,the base plate schedule appears to be missing information regarding base plate <br /> thicknesses. Please clarify if gravity column base plates are to all be 1" thick or if the base plate <br /> thickness schedule requires additional information to be used for the sizes indicated on the plans. <br /> IBC 107.2.1. <br /> 9. On Sheet A1.11, a trash enclosure is proposed to be constructed of concrete walls with masonry <br /> veneer. Please provide structural details for the enclosure as this appears to be missing from <br /> structural plans and current architectural plans do not have construction details for such <br /> construction. IBC 107.2.1. <br /> RESUBMITTAL REQUIREMENTS <br /> In order for the processing of your application to continue, it will be necessary to provide the Building <br /> Division with two new sets of revised construction documents reflecting the corrections requested. <br /> Please include a response letter indicating how the corrections were resolved. <br /> All codes cited refer to the 2015 International Building Code (IBC), 2015 International Existing Building <br /> Code (IEBC),the 2015 International Fire Code (IFC),the 2015 International Mechanical Code (IMC), <br /> and/or the 2015 Washington State Energy Code (WSEC), as amended by the State of Washington and <br /> adopted by the City of Everett. The current IBC referenced standard for accessible design is the 2009 <br /> "Accessible and Usable Buildings and Facilities" ([CC/ANSI A117.1). Federal ADA regulations and <br /> standards may be more restrictive. <br /> Page 2 of 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.