605 MAULSBY LN 2023 Plans 2025-09-26
>
Address Records
>
MAULSBY LN
>
605
>
Plans
>
605 MAULSBY LN 2023 Plans 2025-09-26
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/26/2025 11:41:41 AM
Creation date
9/26/2025 11:41:19 AM
Metadata
Fields
Template:
Address Document
Street Name
MAULSBY LN
Street Number
605
Permit
B2310-119
Year
2023
Notes
UPDATE DECK CONSTRUCTION TO EXISTING CODE
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
8
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
,ZMy6ui ldi ngPermit xom <br /> a service of eCityGov.net Construction Tip Sheet 05 <br /> Deck Construction Notes <br /> • Design loading for decks is based on 60 pounds per square feet (PSF) live load, 10 PSF dead load, and <br /> 1500 PSF soil-bearing capacity. <br /> • All wood must be pressure-treated or naturally resistant to decay (i.e. cedar, redwood, teak). Treat cuts, <br /> holes, and notches with end-cut solution. See Tip Sheet#11 for more information. <br /> • Fasteners, hangers, nails, etc., must be stainless steel, hot-dipped galvanized, or as specifically <br /> required for the specified wood preservative used. The coating weights for zinc-coated fasteners to be in <br /> accordance with ASTM A 153. Provide documentation to your inspector. <br /> • You may modify any components of this tip sheet using accepted engineering practices. Any <br /> modifications must be reviewed prior to permit issuance. <br /> • All attachments must be per manufacturer's installation instructions. <br /> 36"minimum high guard <br /> with intermediate rails Attachment of <br /> spaced so that a sphere pre-manufactured guardail <br /> systems to deck components <br /> 4"in diameter cannot <br /> Existing building shall be per manufacturer. <br /> pass through (See Tip Special blocking details may be <br /> JFlashing Sheet 3). required by the reviewer. <br /> See detail 1 on page <br /> 6 for ledger Refer table on page See page 8 for guardrail <br /> attachment options F 3 for Joist Sizes post connection <br /> Decking and Spans <br /> Secure ballusters with(1)#8d <br /> I wood screw top&bottom <br /> Refer to Table on page 3 for <br /> recommended spacing Beam Size and Spans <br /> re � / P <br /> Note: for drainage <br /> IX <br /> Contractor to field <br /> verify adequacy of Knee braces are required if <br /> solid lumber for ledger distance from grade to top of <br /> connection. If an exit or egress from on page <br /> exceeds 48". See detail <br /> the existing building <br /> passes under the For post size and maximum <br /> proposed deck,or if there allowable height, see page 4 <br /> Is an existing patio under <br /> the proposed deck,6'-8" <br /> minimum clearance must <br /> be maintained. Please <br /> Indicate openings In Manufactured post base cast in <br /> existing wall in elevation footing <br /> view. <br /> Refer to Table on page 4 for <br /> Footing Size <br /> 3,000 psi concrete(no special <br /> inspection required) <br /> Finished grade <br /> 1"clear <br /> Minimum #4 ea.way,3"clear <br /> de th of IBIL I II II I I� to bottom of footing. <br /> P �I�IB�EI I �11 n <br /> footing 12" I�IBI�II�II ° I �II� Footing to bear on <br /> II�Ti�TI�II=1T I I�i���II- undisturbed earth. <br /> May 29,2024 MyBuildingPermit.com I Basic Deck 2 <br /> eCityGov.net <br /> 2:05 eCkyGcvAhance <br />
The URL can be used to link to this page
Your browser does not support the video tag.