Laserfiche WebLink
WALL CONSTRUCTION <br /> TABLE R602.3(1) <br /> FASTENING SCHEDULE <br /> ITEM DESCRIPTION OF BUILDING ELEMENTS NUMBER AND TYPE SPACING AND LOCATION <br /> OF FASTENER'.b,` <br /> Roof <br /> 4-8d box(21/2"x 0.113'D or <br /> 1 Blocking between ceiling joists or rafters to top plate 3-8d common(2'/2"x 0:131');or Toe nail <br /> 3-1 Od box(3"x 0.128),or <br /> 3-3"x 0.131"nails <br /> 4-8d box(2'/2"x 0.113');or <br /> 2 Ceiling joists to top plate 3-8d common(21/2"x 0:131');or per joist,toenail <br /> 3-10d box(3' x 0.128),or <br /> 3-3"x 0.131"nails <br /> Ceiling joist not attached to parallel rafter,laps over 4-1Od box(3"x 0.128');or <br /> 3 partitions(see Section R802.5.2 and Table R802.5.2) 3-16d common(3/z x 0.162');or Face nail <br /> 4-3"x 0.131"nails <br /> ' 4 Ceiling joist attached to parallel rafter(heel joint) Table R802.5.2 Face nail <br /> (see Section R802.5.2 and Table R802.5.2) <br /> Collar tie to rafter,face nail or 1'/4"x 20 ga.ridge strap to 4-10d box(3"x 0.128');or <br /> 5 rafter 3-1 Od common(3"x 0.148�;or Face nail each rafter <br /> 4-3"x 0.131"nails <br /> 3-16d box nails(3'/Z"x 0.135');or 2 toe nails on one side and 1 toe nail <br /> 6 Rafter or roof truss to plate 3-10d common nails(3"x 0.148'�;or on opposite side of each rafter or <br /> 4-10d box(3' x 0.128),or truss' <br /> 4-3"x 0.131"nails <br /> 4-16d(3'/2"x 0.135');or <br /> 3-10d common(3"x 0.148'D;or Toe nail <br /> 4-10d box(3"x 0.128'D;or <br /> 7 Roof rafters to ridge,valley or hip rafters or roof rafter 4-3"x 0.131"nails <br /> to minimum 2"ridge beam 3-16d box 3'/2"x 0.135');or <br /> 2-16d common(3'/2"x 0.162'D;or End nail <br /> 3-10d box(3"x 0.128'�;or <br /> 3-3" 131"nails <br /> Wall <br /> 1 common(3'/Z"x 0.162') 24"o.c.face nail <br /> 8 Stud:totud not at braced wall panels 1 Od box(3"x 0.128');or <br /> 16"o.c.face nail <br /> 3"x 0.131"nails <br /> Stud to stud and abutting studs at intersecting wall corners 16d box(31/2"x 0.135');or 12"o.c.face nail <br /> 9 (at braced wall panels) 3 x 0.131' nails <br /> 16d common(3'/Z"x 0.162') 16"o.c.face nail <br /> 10 Built-up header(2"to 2"header with'/,"spacer) 16d common(3'/z"x 0.162') 16"o.c.each edge face nail <br /> 16d box(31/2"x 0.135') 12"o.c.each edge face nail <br /> 5-8d box(2'/Z"x 0.l l3');or <br /> 11 Continuous header to stud 4-8d common(2'/z"x 0.131');or Toe nail <br /> 4-1 Od box(3"x 0.128') <br /> 16d common(3'/Z"x 0.162') 16"o.c.face nail <br /> 12 Top plate to top plate 1Od box(3"x 0.128'D;or <br /> 3"x 0.131"nails 12"o.c.face nail <br /> 8-16d common(3'/Z"x 0.162'�;or Face nail on each side of end joint <br /> 13 Double top plate splice 12-16d box(3'/2"x 0.135'D;or (minimum 24"lap splice length each <br /> 12-10d box(3 x 0.128 D,or side of end joint) <br /> 12-3"x 0.131"nails <br /> (continued) <br /> 174 2018 INTERNATIONAL RESIDENTIAL CODE® <br />