POWER LIGHTING ONE-LINE DIAGRAM ABBREVIATIONS DRAWING CONVENTIONS <br /> FOR RECEPTACLES IN THIS SECTION, WP DENOTES SEE LUMINAIRE SCHEDULE FOR FURTHER ALL DEVICES THIS SECTION TO BE 3 POLE UNO, A AMMETER, AMPERE M MAGNETIC COIL <br /> WEATHERPROOF WHILE-IN-USE BOX AND GFI INFORMATION. RATINGS AS INDICATED. AC ABOVE COUNTER MCB MAIN CIRCUIT BREAKER A TITLE DETAIL/SECTION TITLE UNDERLINE, <br /> RECEPTACLE. FOR ALL OTHER DEVICES, WP AF AMPERE FRAME MCC MOTOR CONTROL CENTER E1 SCALE: 1/4"=1'-O" E1 = SHEET WHERE REFERENCED <br /> DENOTES NEMA 3R ENCLOSURE UNO. TRANSFORMER, SECONDARY AFF ABOVE FINISHED FLOOR MH MANHOLE, METAL HALIDE <br /> CONVENIENCE RECEPTACLE - r-I VOLTAGE. PHASE AND RATING AFG ABOVE FINISHED GRADE MIN MINIMUM <br /> POLE MOUNTED LUMINAIRE <br /> 3 INDICATED AS APPLICABLE. AHJ AUTHORITY HAVING JURISDICTION MISC MISCELLANEOUS A A <br /> DUPLEX UNO, MOUNTING HEIGHT A DETAIL/SECTION NUMBER <br /> Q3 TO BE 18" AFF UNO WALL SWITCH, SYMBOL INDICATED AIC AMPERE INTERRUPTING CAPACITY MLO MAIN LUGS ONLY E2 E2 E2 = SHEET WHERE SHOWN <br /> 3 = CIRCUIT NUMBER WALL SWITCH LOCATION. SEE GROUND AL ALUMINUM MOV METAL OXIDE VARISTOR <br /> LIGHTING CONTROL SCHEDULE ANN ANNUNCIATOR MPZ COMBINATION TRANSFORMER AND <br /> CONVENIENCE RECEPTACLE - ° FOR WALL SWITCH TYPE AND FUSE ASYM ASYMMETRICAL PANELBOARD <br /> qp FOURPLEX FEATURES. 400 AT AMPERE TRIP MTD MOUNTED N NORTH ARROW <br /> ATS AUTOMATIC TRANSFER SWITCH MTG MOUNTING <br /> SIMPLEX RECEPTACLE WITH Q REMOTE LED DRIVER 400� CIRCUIT BREAKER AUX AUXILIARY MTS MANUAL TRANSFER SWITCH <br /> ® BRASS FLOORPLATE AND SCREW <br /> BLDG BUILDING N NEUTRAL, NEW <br /> CAP REMOTE 0-10V LIGHTING 30 <br /> © ----0 SWITCH BRKR BREAKER NC NORMALLY CLOSED NOTE <br /> CONTROLLER 400 C CONDUIT NEUT NEUTRAL <br /> ® DUPLEX RECEPTACLE - FLUSH pC PHOTOCELL CONTACTOR RELAY REVENUE GRADE METER AND CAN CABLE TELEVISION NO NORMALLY OPEN, NUMBER 0 REVISION REFERENCE <br /> v <br /> MOUNTED IN FLOOR J ENCLOSURE CB CIRCUIT BREAKER NIC NOT IN CONTRACT <br /> FOURPLEX RECEPTACLE - FLUSH CCTV CLOSED CIRCUIT TELEVISION NP NAMEPLATE EQUIPMENT ID TAG - <br /> ® MOUNTED IN FLOOR CURRENT TRANSFORMER CDF CONTROLLED DENSITY FILL 0 PHASE, DIAMETER XXX SEE EQUIPMENT SCHEDULE FOR <br /> CKT CIRCUIT P PANEL, POLE FURTHER INFORMATION, <br /> (2) JUNCTION BOX o p R CENTER LINE PB PUSH-BUTTON =® COORDINATE EQUIPMENT LOCATION <br /> d TRANSFER SWITCH CL CURRENT LIMITING PF POWER FACTOR WITH ASSOCIATED MECHANICAL, <br /> SPECIAL PURPOSE RECEPTACLE, CLF CURRENT LIMITING FUSE PH PHASE CIVIL, ETC. PLANS <br /> DESIGNATION AND AMPERAGE AS CLR CLEAR PIR PASSIVE INFRARED <br /> ®"A" INDICATED, OR SHOWN IN M MOTOR CONNECTION CM CIRCULAR MILS PIV POST INDICATOR VALVE <br /> SCHEDULE, SEE SPECIFICATIONS FEEDER TAG - SEE FEEDER COMM COMMUNICATIONS PNL PANEL <br /> CONNECTION POINT TO XX SCHEDULE FOR FURTHER CONC CONCRETE POMB POSITION ORIENTED MOGUL BASE <br /> EQUIPMENT SPECIFIED FURNISHED INFORMATION CONST CONSTRUCTION (SOCKET) GENERAL NOTES <br /> ® AND INSTALLED BY OTHER CONT CONTINUED PS PRESSURE SWITCH <br /> CPT CONTROL POWER TRANSFORMER PUD SNOHOMISH PUD <br /> TRADES. RACEWAY, CONDUCTOR CR CONTROL RELAY R RELAY 1. MEET ALL REQUIREMENTS OF THE NEC AND AHJ FOR <br /> AND CONNECTION BY ELECTRICAL INSTALLATION AND CONSTRUCTION. <br /> CONTRACTOR. CT CURRENT TRANSFORMER REC RECEPTACLE(S), RECESSED <br /> CONDUIT AND RACEWAY CTRL CONTROL RM ROOM 2. VERIFY LOCATION OF ALL LIFT STATION AND TREATMENT <br /> NONFUSED DISCONNECT SWITCH. CU COPPER SCH SCHEDULE EQUIPMENT WITH CIVIL CONTRACTOR PRIOR TO ROUGH-IN. <br /> ❑� SIZE 30A UNLESS INDICATED ALL CONDUCTORS INCLUDING NEUTRAL AND DDC DEDICATED DIALER CIRCUIT SO SMOKE DETECTOR COORDINATE EXACT CIRCUIT BREAKER, FUSE AND WIRE SIZE <br /> OTHERWISE, 3 POLE UNO GROUND SHALL BE SIZED TO MATCH OR EXCEED DEM DEMAND SF SQUARE FEET WITH CIVIL PRIOR TO ROUGH-IN. <br /> OVERCURRENT PROTECTION DEVICE PER NEC, 2#12, DEMO DEMOLITION SHT SHEET <br /> FUSED DISCONNECT SWITCH. DIM DIMENSION SNOPUD SNOHOMISH PUD 3. ALL EXTERIOR DEVICES TO BE CIRCUITED WITH #10 WIRE <br /> 1#12G MINIMUM UNO. ALL CONDUITS SHALL BE DISC DISCONNECT MINIMUM UNLESS NOTED OTHERWISE. <br /> SIZE INDICATED, (60 = SWITCH SPD SURGE PROTECTIVE DEVICE <br /> ❑F SIZED TO MATCH OR EXCEED QUANTITIES AND DN DOWN SUPV SUPERVISOR <br /> POLE UNO IDS DISCONNECT SWITCH <br /> 60/40 RATING, 40 = FUSE RATING) 3 SIZES OF CONDUCTORS PER NEC, 3/4" MINIMUM SW SWITCH 4. ALL WIRING SHALL BE COPPER UNLESS NOTED OTHERWISE. <br /> UNO. <br /> COMBINATION MOTOR STARTER HOME RUN, DESTINATION DWG DRAWING SWBD SWITCHBOARD 5. VERIFY LOCATIONS OF OTHER UTILITIES PRIOR TO <br /> AND DISCONNECT, SIZE PER SHOWN, CIRCUIT NUMBERS DZ DAYLIGHT ZONE SWGR SWITCHGEAR COMMENCING WORK, PROVIDE REQUIRED CLEARANCES FROM <br /> MANUFACTURER REQUIREMENTS, P1-1,3 PRECEDED BY PANEL NAME, E EMPTY, EXISTING SYM SYMMETRICAL OTHER UTILITIES, BUILDINGS, AND FREESTANDING <br /> m NUMBER OF POLES AS REQUIRED SEE PANEL SCHEDULE, ARROW EF EXHAUST FAN T THERMOSTAT STRUCTURES, DURING INSTALLATION OF CONDUITS, CABLES, <br /> ELEC ELECTRICAL TB TERMINAL BLOCK, TRANSFORMER BANK ETC• <br /> m r� DOES NOT ALWAYS POINT TO ELEV ELEVATION, ELEVATOR TEL TELEPHONE <br /> a PANEL PANEL. EMT ELECTRICAL METALLIC TUBING 6. USE ELECTRICAL PLANS FOR DETERMINING LUMINAIRE AND <br /> TTB TELEPHONE TERMINAL BOARD DEVICE COUNTS. QUANTITIES SHOWN WITHIN CALCULATION <br /> c7 EXIST EXISTING TYP TYPICAL <br /> T TRANSFORMER CONDUIT WITH MEDIUM AND CONTROL SCHEDULES SHALL NOT BE USED FOR BID <br /> UG UNDERGROUND <br /> VOLTAGE CONDUCTORS FACP FIRE ALARM CONTROL PANEL COUNTS. <br /> �H HANDHOLE, SIZE AS NOTED UH UNIT HEATER <br /> fD m CONDUIT WITH LINE VOLTAGE FBOIC FURNISHED BY OTHERS INSTALLED BY UL UNDERWRITERS LABORATORIES 7. NOT ALL COMPONENTS OF THE ELECTRICAL SYSTEMS ARE <br /> CL m T THERMOSTAT P CONTRACTOR UNO UNLESS NOTED OTHERWISE SHOWN FOR CLARITY. PROVIDE MATERIALS AND LABOR <br /> c O CONDUCTORS FLUOR FLUORESCENT ( ) <br /> m UPS UNINTERRUPTIBLE POWER SUPPLY NECESSARY FOR A COMPLETE AND OPERATIONAL SYSTEM. <br /> ^' • GROUND ROD FSA FIRE SYSTEM ANNUNCIATOR V VOLTMETER, VOLT <br /> CONDUIT WITH LOW VOLTAGE VA VOLT AMPERE S <br /> T FT FOOT 8. THE AIC OF THE PANELS SHOWN ARE TENTATIVE AND GIVEN <br /> 3 G GENERATOR CONDUCTORS FTB FLUIDIZED THERMAL BACKFILL ( ) FOR BIDDING PURPOSES ONLY. CONTRACTOR SHALL <br /> -• O VP VAPORPROOF <br /> J CONDUIT DOWN FVNR FULL VOLTAGE NON-REVERSING W WIRE, WATT CALCULATE THE PANEL AIC BASED UPON FINAL CONDUIT <br /> GROUND TEST WELL G,GND GROUND W/ WITH ROUTING AND TRANSFORMERS AND FUSES SUBMITTED. <br /> N CONDUIT UP GA GAUGE GALV GALVANIZED WAC WASHINGTON ADMINISTRATIVE CODE 9, PROVIDE ALL SNOHOMISH COUNTY PUD (SNOPUD) VAULTS <br /> c WHD WATTHOUR DEMAND METER <br /> N CONDUIT STUBBED AND GFI GROUND FAULT CIRCUIT INTERRUPTER PER SNOPUD STANDARDS, SEE SHEET E6.7 FOR FURTHER <br /> CAPPED AS SHOWN GFP EQUIPMENT GROUND FAULT PROTECTION W/o WITHOUT INFORMATION. <br /> GRC,GRS GALVANIZED RIGID STEEL WP WEATHERPROOF <br /> CONDUIT CONTINUED HH HANDHOLE WSEC WASHINGTON STATE ENERGY CODE 10. SEE SHEET C4.17 FOR PRECAST VAULT BEDDING DETAILS <br /> HP HORSEPOWER XFMR TRANSFORMER <br /> AND SUBGRADE PREPARATION. ALL PRECAST VAULTS <br /> EXPOSED FLEX CONDUIT HPS HIGH PRESSURE SODIUM 3P 3-POLE SUBJECTED TO TERMINAL LOADS SHALL BE CONTRACTOR <br /> VAC HEATING, VENTILATION, AIR CONDITIONING DESIGNED TO MEET THE UNDERGROUND UTILITY STRUCTURE <br /> H <br /> HHVA HOT WATER HEATER LOADING CRITERIA SHOWN ON SHEET G1.3. SEE <br /> INTERRUPTING CAPACITY SPECIFICATIONS FOR FURTHER DETAILS. <br /> JB,J-BOX JUNCTION BOX 11. PROVIDE INTEGRAL LOCKS OR PADLOCK EYES FOR ALL <br /> w K KELVIN ENCLOSURE DOORS. PROVIDE LOCKABLE HANDLES FOR ALL <br /> KCM THOUSAND CIRCULAR MILS DISCONNECTS. <br /> KV KILOVOLT 12. PROVIDE NEMA 4X STAINLESS STEEL HOUSINGS FOR ALL <br /> a , KVA KILOVOLT AMPERE(S) SWITCHBOARDS, PANELBOARDS, TRANSFORMERS, <br /> • KW KILOWATT(S) DISCONNECTS, COMMUNICATIONS CABINETS AND COMBINATION <br /> o LC LIGHTING CONTACTOR TRANSFORMER-PAN ELBOARDS UNLESS NOTED OTHERWISE. <br /> 1 LED LIGHT EMITTING DIODE <br /> N <br /> N <br /> Know what's below. IF SHEET IS LESS THAN 22x34 <br /> Call before you dig. REDUCE SCALE ACCORDINGLY LV <br /> s \ <br /> E PROJECT ENGINEER: SCALE: / <br /> PORT OF EVERETT DWG. N0. EO■ LU <br /> 3 ��O A I � S K.g� D. SIATERLIS NONE 1 <br /> I �I d DESIGNED BY: DATE: <br /> Port of lr�ff ASSOCIATES,INC. q�� iN D. SIATERLIS 05/07/2021 N O R T 0 N TERMINAL DEVELOPMENT CIP NO. <br /> M EVERE DRAWN BY: CHECKED BY: MTCA 3RD INTERIM ACTION 1-8-soo—o5 <br /> 16—hAvence,Suhe1300 ENGINEERS-CONSULTANTS <br /> Seattle,Washington 98101 o C. SMITH S. BARTKOSKE PROJECT <br /> P.O. BOX 538 1206)382-0600 Far('06)382-0600 (206)243-5022 w elcon.com , , ,, ELECTRICAL LEGEND <br /> PROJECT NO.1600120 1 6 21 2021 DKS ISSUED FOR BID �tri N0. MT-NT-2021-02.2 <br /> EVERETT, WA 98206 16300 CHRISTENSEN ROAD,STE 330 0 5/07/2021 DKS FOR CITY REVIEW SIONAL APPROVED BY: <br /> SEA TTLE,WA98188 & ABBREVIATIONS SHEET NO. 103 OF 150 0 <br /> (425) 259-3164 N0. DATE BY REVISION N0. DATE BY REVISION (�/Ib/2 <br /> K <br />