2600 FEDERAL AVE 2021 PORT OF EVERETT Plans 2025-09-26
>
Address Records
>
FEDERAL AVE
>
2600
>
PORT OF EVERETT
>
Plans
>
2600 FEDERAL AVE 2021 PORT OF EVERETT Plans 2025-09-26
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/26/2025 2:02:42 PM
Creation date
9/26/2025 1:56:04 PM
Metadata
Fields
Template:
Address Document
Street Name
FEDERAL AVE
Street Number
2600
Tenant Name
PORT OF EVERETT
Permit
PW2112-023
Year
2021
Notes
SITEWORK FEDERAL AVE AND NORTON TERMINAL
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
150
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ABBREVIATIONS (CONTINUED <br /> FDN FOUNDATION AWP NTERIM ACTION WORK PLAN OC ON CENTER SCH SCHEDULE T TELECOMMUNICATION UTILITY <br /> FG FINISH GRADE IE INVERT ELEVATION OHW ORDINARY HIGH WATER SD STORM DRAIN T&B TOP AND BOTTOM <br /> FH FIRE HYDRANT K—C KIMBERLY—CLARK OPP OPPODITE SDFM STORM DRAIN FORCE MAIN TB THRUST BLOCK <br /> FL FLOW LINE KILL KIPS PER LINEAL FOOT OWS OIL/WATER SEPARATOR SDMH STORM DRAIN MANHOLE TIC TOP OF CURB <br /> TO FIBER OPTIC LF LINEAR FEET P POWER SF STORM FILTER TD TRENCH DRAIN <br /> FT FEET LOG LOCATION PDA PILE DRIVING ANALYZER SIM SIMILAR TYP TYPICAL <br /> G GAS LS LANDSIDE PP POWER POLE SNO PUD SNOHOMISH COUNTY PUBLIC UTILITY DISTRICT U UNKNOWN UTILITY <br /> GALV GALVANIZED MAT'LS MATERIALS PRV PRESSURE REDUCING VALVE SOW SCOPE OF WORK UGP UNDERGROUND POWER <br /> GLO GOVERNMENT LAND OFFICE ME MATCH EXISTING PSI POUNDS PER SQUARE INCH SS SANITARY SEWER, STAINLESS STEEL UNC UNIFIED NATIONAL COARSE <br /> GS GROUND SURFACE MIT MANHOLE PVC POLYVINYL CHLORIDE SSFM SANITARY SEWER FORCE MAIN UNO UNLESS NOTED OTHERWISE <br /> GV GATE VALVE MHHW MEAN HIGHER HIGH WATER PVMT PAVEMENT SSMH SANITARY SEWER MANHOLE VEG VEGETATION <br /> GVL GRAVEL MHW MEAN HIGH WATER REF REFERENCE DIMENSION SSS SIDE SANITARY SEWER VERT VERTICAL <br /> HAZMAT HAZARDOUS MATERIALS MIN MINIMUM REINF REINFORCEMENT ST STREET VIE VERIFY IN FIELD <br /> HDPEHIGH DENSITY POLYETHYLENE MLLW MEAN LOWER LOW WATER REPL REPLACE STD STANDARD W WATER <br /> HTL HIGH TIDE LINE MLW MEAN LOW WATER REQ'D REQUIRED SWPPP STORMWATER POLLUTION PREVENTION PLAN WHS WELDED HEADED STUD <br /> HMA HOT MIX ASPHALT MSRC MARINE SPILL RESPONSE CORPORATION REV REVISION SYMM SYMMETRIC W/ WITH <br /> HORIZ HORIZONTAL MTCA MODEL TOXICS CONTROL ACT RD ROAD W/0 WITHOUT <br /> HE HIGH POINT MW MONITORING WELL R.O.W. RIGHT—OF—WAY WABO WASHINGTON ASSOCIATION OF <br /> NIC NOT IN CONTRACT RPBA REDUCED PRESSURE BACKFLOW ASSEMBLY BUILDING OFFICIALS <br /> NT NORTON TERMINAL RW RETAINING WALL WM WATER MAIN <br /> NTS NOT TO SCALE WS WATERSIDE <br /> GENERAL NOTES: <br /> 1 ALL CURRENT VERSION SHALL OF THE CITY OF EVERETT TO SE PLANS STANDARDS.ND SPECIFICATIONS AND THE 11. REQUIREMENTS.SHORING AND SEE SPION SHALL BE IN ECIFICATIONS ICATIONS FOR ADDITIONAL WITH STATE AND REQUIREMENTS. FEDERAL LEGEND: <br /> 2. CONTRACTOR SHALL VERIFY ALL LEVELS, DIMENSIONS, AND EXISTING CONDITIONS IN THE 12. THE CONTRACTOR SHALL KEEP ALL STREETS AND VEHICULAR TRAFFIC AREAS USED FOR ® BORE HOLE EXISTING CONTOUR <br /> FIELD BEFORE PROCEEDING. CONTRACTOR SHALL NOTIFY THE ENGINEER OF ANY THIS WORK CLEAN AT ALL TIMES, SEE SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. ® MONUMENT WELL xxx— CLF EXISTING CHAINLINK FENCE <br /> DISCREPANCIES OR FIELD CHANGES PRIOR TO INSTALLATION OR FABRICATION. IN CASE I WATER VALVE OHW OHW EXISTING OVERHEAD WIRE LINE <br /> OF DISCREPANCIES BETWEEN THE EXISTING CONDITIONS AND THE PLANS, THE 13. CONTRACTOR IS RESPONSIBLE FOR ANY TRAFFIC CONTROLS REQUIRED DURING THE o— WATER SPIGOT <br /> CONTRACTOR SHALL OBTAIN DIRECTION FROM THE ENGINEER BEFORE PROCEEDING. DURATION OF THIS PROJECT, PER CONTRACTOR'S OPERATION. ALL TRAFFIC CONTROL ss SS EXISTING SANITARY SEWER LINE <br /> DIMENSIONS AND CALLOUTS NOTED AS PLUS OR MINUS (t) OR (REF) INDICATE SHALL BE IN ACCORDANCE WITH THE MANUAL OF UNIFORM TRAFFIC CONTROL DEVICES. O SANITARY SEWER MANHOLE <br /> UNVERIFIED DIMENSIONS AND ARE APPROXIMATE. NOTIFY THE ENGINEER IMMEDIATELY OF 0 STORM DRAIN MANHOLE ueP ucP EXISTING UNDERGROUND POWER LINE <br /> CONFLICTS OR EXCESSIVE VARIATIONS FROM AS INDICATED. NOTED DIMENSIONS TAKE 14. CONTRACTOR SHALL BE AWARE OF FACILITY OPERATION REQUIREMENTS AND SHALL o TELEPHONE RISER w W EXISTING WATER LINE <br /> PRECEDENCE OVER SCALED DIMENSIONS — DO NOT SCALE THE PLANS. COORDINATE ACCESS TO THE SITE WITH THE ENGINEER. CONTRACTOR SHALL MAINTAIN F❑ EO EXISTING FIBER OPTIC <br /> ADJACENT TENANT ACCESS AT ALL TIMES AND SHALL NOT RESTRICT TENANT OPERATIONS E-- GUY ANCHOR <br /> 3. ALL LOCATIONS OF EXISTING STRUCTURES AND UTILITIES SHOWN HEREIN HAVE BEEN WITHOUT APPROVAL OF THE ENGINEER. E3EM ELECTRIC METER SD ED EXISTING STORM DRAIN <br /> OBTAINED FROM AVAILABLE RECORDS AND SHOULD, THEREFORE, BE CONSIDERED ¢ LUMINARE —BP-- BP BURIED POWER LINE <br /> APPROXIMATE ONLY AND NOT NECESSARILY COMPLETE. IT IS THE RESPONSIBILITY OF THE 15. THE CONTRACTOR SHALL PLACE CONSTRUCTION DEBRIS CONTROL DEVICES, BOOMS, T T T TELEPHONE LINE <br /> CONTRACTOR TO INDEPENDENTLY VERIFY THE ACCURACY OF ALL UTILITY LOCATIONS TARPAULINS AND OTHER DEVICES AS NECESSARY TO PREVENT DEBRIS FROM ENTERING EXISTING PIPE SLOPE <br /> SHOWN AND TO FURTHER DISCOVER AND AVOID OTHER UTILITIES NOT SHOWN HEREIN THE WATER, AND AIR BORNE MATERIALS FROM LEAVING THE IMMEDIATE VICINITY OF THE W WATER LINE <br /> PROPOSED PIPE SLOPE DIRECTION <br /> WHICH MAY BE AFFECTED BY THE IMPLEMENTATION OF THIS PLAN. THE CONTRACTOR SITE. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CLEANUP OF ANY MATERIALS —— PROPERTY LINE <br /> SHALL POTHOLE OR OTHERWISE CONFIRM EXISTING CONDITIONS, SPECIFICALLY PIPE SIZES DEPOSITED OUTSIDE THE WORK AREA. ^ EXISTING GRADE SLOPE DIRECTION <br /> PRIOR TO CONSTRUCTION, AND BRING ANY CONFLICTS BETWEEN EXISTING CONDITIONS -- -- LEASE LIMIT <br /> AND NEW WORK TO THE ENGINEER'S ATTENTION. 16. MAINTAIN UTILITY SERVICE TO EXISTING BUILDINGS, UTILITIES AND FIRE HYDRANTS DURING PROPOSED GRADE SLOPE DIRECTION EASEMENT <br /> CONSTRUCTION UNLESS NOTED OTHERWISE OR APPROVED BY THE ENGINEER. INSTALL T� FIRE HYDRANT —W—W— WATER <br /> 4. THE EXISTING NORTON TERMINAL SITE UTILITIES HAVE UNDERGONE NUMEROUS REPAIR NEW UTILITY LINES TO POINTS OF CONNECTION TO EXISTING UTILITY LINE PRIOR TO <br /> AND UPGRADE PROJECTS SINCE THE TIME OF THE ORIGINAL CONSTRUCTION. THESE DEMOLITION OF THE EXISTING LINES, UNLESS NOTED OTHERWISE. WATER SERVICE O LIGHT POLE SS SS SEWER <br /> REPAIRS MAY NOT ALL BE REFLECTED IN THESE CONTRACT DOCUMENTS. REFERENCE SHUTDOWNS WILL BE LIMITED TO 2 HOURS FOR EACH UTILITY CROSSOVER AND SHALL SD STORMWATER <br /> DRAWINGS FOR THESE CONTRACTS ARE AVAILABLE FROM THE PORT OF EVERETT. IT IS BE COORDINATED WITH THE ENGINEER. POWER AND COMMUNICATION SHUTDOWNS SHALL TRENCH DRAIN <br /> ANTICIPATED THAT MOST SITE UTILITIES WERE DEMOLISHED OR ABANDONED DURING BE LIMITED AND SHALL BE COORDINATED WITH THE ENGINEER. SEE SPECIFICATIONS FOR <br /> DEMOLITION OF FORMER KIMBERLY—CLARK SITE. FURTHER SHUTDOWN REQUIREMENTS. FENCE <br /> PROPOSED CONTOUR <br /> 5. A COPY OF THE PLANS SHALL BE ON—SITE WHENEVER CONSTRUCTION IS IN PROGRESS. 17. CONTRACTOR—INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO THE PORT FOR <br /> THROUGHOUT THE PROGRESS OF THE WORK OF THIS CONTRACT, THE CONTRACTOR APPROVAL PRIOR TO FABRICATION OR CONSTRUCTION. CHANGES SHOWN ON SHOP <br /> SHALL MAINTAIN AN ACCURATE RECORD OF ALL CHANGES IN THE CONTRACT DOCUMENTS. DRAWINGS ONLY WILL NOT SATISFY THIS REQUIREMENT. <br /> UPON THE COMPLETION OF THIS CONTRACT, THE CONTRACTOR SHALL PROVIDE ONE REFERENCE SYMBOLS: <br /> COMPLETE SET OF CONTRACTOR REDLINE AS—BUILT TO THE PORT OF EVERETT. 18. THE CONTRACTOR SHALL TAKE NECESSARY MEASURES TO PREVENT INTERRUPTION OF <br /> OPERATIONS AND PROTECT ALL EXISTING SURFACES/STRUCTURES TO REMAIN AT THE <br /> 6. THE CONTRACTOR SHALL LOCATE ALL UTILITIES WITHIN THE PROJECT SITE PRIOR TO FACILITY DURING CONSTRUCTION. DETAILS SHALL BE PRESENTED IN THE CONTRACTOR'S DETAIL # <br /> WORK. CONTRACTOR SHALL CONTACT 811 "CALL BEFORE YOU DIG" AND AN INDEPENDENT WORK PLAN. SECTION OR ELEVATION # <br /> LOCATING SERVICE TO LOCATE ALL UTILITIES AT LEAST 48 HOURS PRIOR TO WORK. <br /> 19. PROJECT NORTH AS INDICATED ON THESE DRAWINGS IS FOR CONVERSATIONAL GENERAL G1.0 G1.1 <br /> 7. THE CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS OF EXISTING STRUCTURES AND DIRECTIONAL REFERENCE. BEARINGS NOTES ON DRAWINGS ARE RELATIVE TO TRUE NORTH. SHEET #�" SHEET # <br /> OTHER FEATURES THAT MAY IMPACT THE WORK. CONTRACTOR SHALL BRING ANY , C1.1 WHERE DETAIL <br /> CONFLICTS TO THE ENGINEER'S ATTENTION PRIOR TO BEGINNING AFFECTED WORK. 20. CONTRACTOR SHALL BE RESPONSIBLE FOR ERECTION STABILITY AND TEMPORARY SHEET # SHEET # IS CALLED FROM WHERE DETAIL <br /> SUPPORT AS NECESSARY. DETAILED CONSTRUCTION PLANS SHALL BE PREPARED BY THE OCCURS <br /> 8. ANY DAMAGE TO EXISTING UTILITIES, OTHER FACILITIES OR EQUIPMENT DUE TO THE CONTRACTOR AND APPROVED BY THE PORT PRIOR TO MOBILIZATION. WHERE SECTION WHERE SECTION <br /> OR ELEVATION OR ELEVATION OCCURS <br /> CONTRACTOR'S NEGLIGENCE, EXCEPT FOR ITEMS DESIGNATED FOR DEMOLITION, SHALL BE IS CALLED FROM <br /> PROMPTLY REPAIRED BY THE CONTRACTOR AT HIS EXPENSE. THIS INCLUDES ITEMS 21. SEE ALSO STRUCTURAL GENERAL NOTES ON SHEETS S1.1—S1.3. <br /> OUTSIDE THE WORK AREA AND WITHIN THE PORT OF EVERETT PROPERTY THAT ARE / PROJECT <br /> DAMAGED BY CONSTRUCTION ACTIVITIES DURING EXECUTION OF THIS CONTRACT. 22. NORTON TERMINAL IS ON THE WASHINGTON STATE DEPARTMENT OF ECOLOGY LIST OF NORTH <br /> CONTAMINATED SITES AND IS CURRENTLY IN THE MTCA CLEANUP PROCESS. REFER TO <br /> 9. PRIOR TO LAYING PIPE, THE CONTRACTOR SHALL EXPOSE EXISTING WATER, STORM WATER THE SOIL AND GROUNDWATER MANAGEMENT PLAN IN APPENDIX B OF THE SPECIFICATIONS X SECTION/DETAIL NORTH ARROW INDICATES <br /> m AND SEWER PIPING AT CONNECTION POINTS TO VERIFY THAT FIELD CONDITIONS MATCH FOR ADDITIONAL INFORMATION. X X SCALE: 1/2" = 1'—O" TRUE NORTH <br /> INFORMATION SHOWN ON THE PLANS, SPECIFICALLY THE LOCATION, ELEVATION, DIAMETER, <br /> AND MATERIAL OF EXISTING PIPE. CONTRACTOR SHALL CONTACT THE ENGINEER IF 23. SEE SHEET G1.3 FOR UNDERGROUND STRUCTURE LOADING CRITERIA REQUIREMENTS. VERT DATUM: NAVD 88 <br /> n DISCREPANCIES ARE DISCOVERED. ` City of Everett CONV TO MLLW = NAVD88+2.03 <br /> EVERETT Reviewed for Permit 10/26/2021 HORZ DATUM: NAD 83/91 <br /> 10. ALL ACTIVATION AND DEACTIVATION OF UTILITIES SHALL BE COORDINATED WITH THE W <br /> UTILITY AND THE ENGINEER IN ADVANCE. PROVIDE A MINIMUM OF 3 DAYS ADVANCE IF SHEET IS LESS THAN 22x34 <br /> a m WRITTEN NOTICE TO THE UTILITY AND ENGINEER. REDUCE SCALE ACCORDINGLY > <br /> LU <br /> fD PROJECT ENGINEER: SCALE: DWG. NO. <br /> P� A. N. WATSON AS SHOWN PORT OF EVERETT G1.2 <br /> 5�'oY �' <br /> Port Of DESIGNED BY: DATE: <br /> =`� _ �y J. BECKER 05/07/2021 NORTON TERMINAL DEVELOPMENT OF NO. <br /> o Minn L/ EREi i 1Tff / .� - DRAWN BY: CHECKED BY: & MTCA 3RD INTERIM ACTION 1-8-900-05 V <br /> 16015th Avenue,Suite 1300 K. EDWARDS, D. YU N. WATSON PROJECT <br /> N P.O. BOX 538o'Ra7o1a� GENERAL NOTES AND LEGEND <br /> Seattle,Washington 98101 ® 05/07/2021 NW FOR CITY REVIEW '`�s,o�L ,c,� �4y APPROVED BY: NO. MT—NT-2021—02.2 <br /> N EVERETT, WA 98206 (206)382-0600 Fax(206)382-0500 O <br /> (425) 259-3164 PROJECT NO.1600120 NO. DATE BY REVISION NO. DATE BY REVISION �\ SHEET NO. 03 OF 149 LL <br />
The URL can be used to link to this page
Your browser does not support the video tag.