My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2600 FEDERAL AVE 2021 PORT OF EVERETT Plans 2025-09-26
>
Address Records
>
FEDERAL AVE
>
2600
>
PORT OF EVERETT
>
Plans
>
2600 FEDERAL AVE 2021 PORT OF EVERETT Plans 2025-09-26
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/26/2025 2:02:42 PM
Creation date
9/26/2025 1:56:04 PM
Metadata
Fields
Template:
Address Document
Street Name
FEDERAL AVE
Street Number
2600
Tenant Name
PORT OF EVERETT
Permit
PW2112-023
Year
2021
Notes
SITEWORK FEDERAL AVE AND NORTON TERMINAL
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
150
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
WRAP PIPE AND ALL FITTINGS WITH J" 3/4" FREEZELESS YARD HYDRANT, <br /> z MIN WOODFORD MODEL Y34 OR EQUAL <br /> THICK FIBER GLASS PIPE INSLULATION WITH WATTS FIBERGLASS THERMAL & HOSE CONN VACUUM BREAKER-- 1'-6" <br /> ALUMINUM COVER. SEE SHEET ELEC DWG'S ENCLOSURE WITH HEATER, HOT VALVE <br /> FOR POWER OUTLET DETAILS. BOX MODEL #WB-N3 OR EQUAL 9" MIN DEPTH, 18%18" BOX LID g„ PROVIDE (4) #3 BARS <br /> \2" RPBA (I.D. 70"Lx26"Wx45"H) 1" GS RISER PIPE REINFORCED CONC PAD CONIC PAD <br /> I <br /> TEE SS TEE & 2" PRV, WILKINS SERIES 600 n <br /> PIPE NIPPLES, TYP OR APPROVED EQUAL (SET N <br /> 2" SS UNION, TYP PER Lo <br /> FOR 60 PSI) VALVE°BOX)DETAILL 3SPLAN <br /> DRAIN HOLE, LOC TO SLOPE AWAY VIEW ON THIS SHEET (SEE SECTION A) <br /> 2" SS PIPE, TYP � FROM HOT BOX & BLDG'S <br /> SECURE HOTBOX TO CONIC SLAB PER CONICSLAB 1"x90* GI BEND PLAN <br /> MANUFACTURER SPECIFICATION \ (84"Lx42"Wx6"THICK) 9" THICK, REINFORCED <br /> FINISH GRADE d GONG PAD, SEE PLAN <br /> 1" CHAMFER, TYP 1" HDPExGS TRANS FITTING ABOVE FOR DIMENSIONS <br /> #4 BARS AT 12" OC EACH WAY IN o <br /> CENTER OF SLAB. ADJUST BARS AS <br /> REQUIRED UP TO 6" BUT WITHOUT VALVE STAND 1%2" HDPE REDUCER <br /> EXCEEDING THE 12" MIN SPACING <br /> FOR CONFLICTS WITH PIPE 2" HDPExSS <br /> 2" HDPExSS TRANS FITTING 1/8" NPT DRAIN HOLE �V AVAA• �� <br /> PENETRATIONS. SEE SPECS AND TRANS FITTING \ \ <br /> SHT S1.3 FOR REBAR DETAILS. GATE VALVE <br /> 2" HDPE DOM W 2" HDPE DOM W <br /> TO RPBA <br /> CONIC SUPPORT/ 2"x90° HDPE BEND <br /> 2"x90° HDPE BEND THRUST RESTRAINT THRUST BLOCK <br /> 2" HDPE PIPE <br /> FROM WM ao TO TRAILERS 1/2" WASHED GRAVEL / <br /> 2' MIN 1 SECTION A <br /> IN MTCA SOW IN MTCA SOW DETAILS 1, 3 AND 4 SHALL IN AND OUT MTCA SOW <br /> CONFORM TO COE STD DWGS <br /> 2 POTABLE WATER SERVICE RPBA AND HOTBOX DETAIL YARD HYDRANT DETAIL 518, 505 AND 614 RESPECTIVELY. Z VALVE BOX <br /> 1 •J <br /> C5.1, C5.3 C5.20 SCALE: NITS C5.1, C5.2 C5.20 SCALE: NITS <br /> C5.9 C5.20 SCALE: NTS <br /> 12" OVERLAP WITH EX <br /> HMA PAVEMENT <br /> 1 <br /> EX HMA PAVEMENT MATCH FLUSH WITH FINISHED GRADE <br /> T- C <br /> EXISTING SURFACE <br /> POTABLE WATER SERVICE0 RPBA AND HOT BOX W A T E R M A I N <br /> 2-0 STRUCTURAL <br /> TRENCH NOTES BACKFILL, <br /> SEE NOTE 3 <br /> 1. PLACE THE APPROPRIATE UTILITY 3' MIN COVER SHORING OR EXTRA o <br /> SHORING OR EXTRA ��A�\ MARKING TAPE, WITH METAL FIBERS, 12" EXCAVATION ZONE •• <br /> 4' MIN COVER ABOVE THE PIPE CONTINUOUSLY ALONG 1.5H:1V MAX <br /> EXCAVATION ZONE �j STRU SEERAL NOTEBA3KFILL, THE PIPE LENGTH. UNDERGROUND MARKING /12 TRENCH <br /> 1.SH:1V MAX <br /> TRENCH 2. PIPE ZONE BEDDING SHALL BE CRUSHED It TAPE SEE NOTE 1 PIPE ZONE <br /> SURFACING BASE COURSE, COMPACT TO BEDDING, <br /> 0 12„ 90% MAXIMUM DENSITY. SEE NOTE 2 <br /> j UNDERGROUND MARKING <br /> TAPE, SEE NOTE 1 PIPE ZONE 3. BACKFILL SHALL BE IMPORTED <br /> BEDDING, STRUCTURAL FILL OR EQUIVALENT 6 IN MIN, 6" <br /> GEOTEXTILE FOR SEE NOTE 2 SUITABLE NATIVE MATERIAL AS APPROVED TYP <br /> SEPARATION, SEE NOTE 4 BY THE ENGINEER OR PIPE BEDDING CAN <br /> BE EXTENDED TO PAVEMENT SUBGRADE IF <br /> 6 IN MIN, 6" DISTANCE IS 12 INCHES OR LESS 2 6" <br /> TYP —L 11 COMPACT TO 95% MAXIMUM DENSITY. <br /> 4. FILTER FABRIC SHALL BE FILTER FABRIC COMPACT SUBGRADE TCI_/� <br /> FOR SEPARATION PER WSDOT/APWA 95% MAXIMUM DENSITY <br /> 2'-6" STANDARD SPECIFICATION 9-33.2, NON <br /> 1 BOLLARD COMPACT SUBGRADE To OUT MTCA SOW WOVEN. IN AND OUT MTCA SOW <br /> C5.9 C2.3 95%MAXIMUM DENSITY <br /> TYPICAL WATERMAVN TRENCH FOR FEDERAL AVENUE TYPICAL TRENCH FOR PRESSURIZE® PIPE <br /> HOT BOX BOLLARD PROTECTION 4 W1 STA 4+ 16 THROUGH W1 10+00) 5 AND WATER LONES FOR NORTON TERMINAL <br /> �" 2� <br /> �,<' SCALE: NITS C5.1, C5.2 C5.20 SCALE: NITS C5.1, C5.2 C5.20 SCALE: NITS <br /> rtt City of Everett IF SHEET IS LESS THAN 22x34 W <br /> EVERETT Reviewed for Permit 10/26/2021 REDUCE SCALE ACCORDINGLY > <br /> CD ..RE <br /> N PROJECT ENGINEER: SCALE: <br /> �� PORT OF EVERETT DWG. NO. <br /> C5.20 <br /> p. N. WATSON AS SHOWN <br /> `C�gp4��Q�N TiP DESIGNED BY: DATE: <br /> 0 <br /> Port of =��,t aye J. BECKER 05/07/2021 NORTON TERMINAL DEVELOPMENT CIP No. H <br /> p0'' 1-8-900-05 <br /> EVERETT - DRAWN BY: CHECKED BY: « MTCA 3 R D INTERIM ACTION <br /> U <br /> v` K. EDWARDS, D. YU N. WATSON PROJECT <br /> 16015th Avenue,Suite 1300 0 06/21/2021 NW ADDED DETAILS AND NOTES a7014 e NO. MT—NT-2021-02.2 <br /> N P.O. BOX 538 Seattle,Washington 98101 ® 05/07/2021 NW FOR CITY REVIEW �j ��T"b� APPRovED BY: WATER DETAILS <br /> N EVERETT, WA 98206 (206)382-0600 Fax(206)382-0500ioaat ~ <br /> (425) 259-3164 PROJECT NO.1600120 NO. DATE BY REVISION NO. DATE BY REVISION SHEET NO. 77 OF 149 LL <br />
The URL can be used to link to this page
Your browser does not support the video tag.