My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2600 FEDERAL AVE 2021 PORT OF EVERETT Plans 2025-09-26
>
Address Records
>
FEDERAL AVE
>
2600
>
PORT OF EVERETT
>
Plans
>
2600 FEDERAL AVE 2021 PORT OF EVERETT Plans 2025-09-26
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/26/2025 2:02:42 PM
Creation date
9/26/2025 1:56:04 PM
Metadata
Fields
Template:
Address Document
Street Name
FEDERAL AVE
Street Number
2600
Tenant Name
PORT OF EVERETT
Permit
PW2112-023
Year
2021
Notes
SITEWORK FEDERAL AVE AND NORTON TERMINAL
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
150
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FENCING NOTES CL OF FENCE LINE NOTES: <br /> 1. UNLESS OTHERWISE NOTED ALL SECURITY FENCE SECURE NON-SECURE 1. ALL FENCING MATERIALS SHALL BE <br /> SHALL BE PER DETAIL(-_1__' TERMINAL TERMINAL GALVANIZED, UNLESS NOTED OTHERWISE. <br /> 2„ <br /> C6.5 C6.5 18" DIA CONCERTINA SEE DETAIL 2 THIS SHEET <br /> 2. ALL CHAIN LINK FENCE SHALL BE BLACK VINYL WIRE, SECURE SIDE <br /> LOCK PIN & <br /> COATED, INCLUDING GATES, RAILS, RODS, I <br /> BARBED WIRE, TYP <br /> EXTENSION ARMS, POSTS, CONNECTIONS, BARB TOP RAIL LOCK PIN & <br /> WIRE, AND FABRIC. <br /> CHAIN LINK FABRIC BARBED WIRE, TYP <br /> 3. WIRE TIES, RAILS, POSTS AND BRACES SHALL BE /� yP <br /> CONSTRUCTED ON THE SECURE SIDE OF THE <br /> FENCE ALIGNMENT. CHAIN LINK FABRIC SHALL BE <br /> o <br /> PLACED ON THE OPPOSITE SIDE OF THE SECURE FENCE POST <br /> BARRIER. <br /> WIRE TIES AT 2' = CUT-OUT FOR <br /> 4. EXTENSION ARMS SHALL BE PLACED ON ALL LINE O.C. ALONG FENCE TOP RAIL, TYP <br /> AND CORNER FENCE POSTS. GATE END POSTS Z <br /> SHALL BE INSTALLED WITH POST CAPS. N� 3/8" PLAIN PIN RIVETED FLUSH, TYP <br /> 5. CONTRACTOR SHALL NOT REUSE ANY EXISTING RIVETED <br /> PLAIN PIN <br /> R <br /> FENCING OR BARBED WIRE WITHOUT APPROVAL OF I RIVETED FLUSH, TYP <br /> ENGINEER. <br /> FABRIC SHALL BE INSTALLED <br /> 6. WHERE NEW FENCE LINE MATCHES EXISTING WITH NO GAPS GREATER THAN <br /> FENCE LINE, CONTRACTOR SHALL DEMOLISH L 2" BETWEEN BOTTOM OF <br /> EXISTING FENCE AND GATES ONLY WHERE PLAN FABRIC AND GRADE SURFACE <br /> INDICATES INSTALLATION OF NEW TWIC SECURITY NOTES: <br /> CHAIN LINK FENCE AND GATES. WHERE FENCING IS LOCATED ON A SLOPE LINE POST CORNER POST <br /> GREATER THAN 2% THE CONTRACTOR <br /> 7. CONTRACTOR SHALL SALVAGE AND REUSE SIGNAGE SHALL INSTALL A BOTTOM RAIL <br /> THAT IS IN GOOD CONDITION. SIGNS THAT ARE q SECTION - TYPICAL SECURJY FENCE 2 EXTENSION ARMS <br /> FADED OR DAMAGED IN ANY WAY SHALL NOT BE <br /> SALVAGED OR REUSED. C6.5 C6.5 SCALE: NTS - - SCALE: NTS <br /> TOP RAIL - CONTINUOUS, TIE WIRES FOR FABRIC TO RAILS <br /> 1.66" 0 @ 2.27 LB/FT OR AT 2'-0" O.C. (NOT SHOWN) <br /> "C" SECTION @ 1.40 LB/FT EXTENSION ARM PULL POST <br /> A LOCK WIRE FOR BARBED PLAIN RAIL COUPLING, EXPANSION <br /> 3 ROWS, 2 STRAND, WIRE PLACED INSIDE ARM TYP, SEE DETAIL 2 SEE DETAIL 1 <br /> END, GATE OR C6.5 C6.5 ON C6.12 ON SHEET C6.12 STRING COUPLINGS AT 100 FT INTERVALS <br /> CORNER POST 12.5 GA STANDARD BARBED SELVAGES RAIL COUPLING <br /> LE i <br /> BARBED WIRE, 4 POINT, TOP & BOTTOM <br /> 14 GA BARBS 5" O.C. <br /> PRESSED STEEL TOP <br /> PINNED TO END OR <br /> CORNER OF POST <br /> SEE DETAIL 2 ON C6.12 <br /> LINE POST, 2.875" O.D. <br /> BRACE RAIL, 1.66"0 GROUP IC HIGH CARBON 9 GA-2" MESH CHAIN TENSION BARS <br /> XXX LINK FABRIC 70,000 PSI <br /> @ 2.27 LB/FT OR "C" STEEL PIPE (Fy=50ksi) SEE DETAIL 1 <br /> SECTION @ 1.40 LB/FT @ 4.64LB/FT >00 STRENGTH BARBED TOP ON SHEET <br /> 'Mi <br /> ND BOTTOM C6.12 FOR <br /> TENSION BAND, TYP CONNECTIONS <br /> 1/4" X 3/4" TENSION OFFSET CUPS, TYP <br /> BAR, TYP (NOT SHOWN). <br /> 3 8 0 TRUSS ROD, °c <br /> END, CORNER OR PULL AND TIGHTENER TYP <br /> POSTS 3.5" O.D. GROUP IC ) ) ) FENCING SIGNS <br /> HIGH CARBON STEEL PIPEKXXoo, BRACE RAIL <br /> (Fy=50ksi) @ 5.71 LB/FT <br /> TENSION WIRE <br /> K� 1 <br /> :8� <br /> TRUSS ROD <br /> #7 GA SPRING COILED 10' TYP. ALL FOUNDATION CONCRETE SHALL <br /> TENSION WIRE, TYP 4" BE RAISED 1/4" ABOVE FINISHED <br /> CONCRETE FOUNDATION DIMENSIONS GRADE AND ROUNDED TO MATCH <br /> LOCATION a b c FINISHED GRADE AT EDGE CALL 48HOURS <br /> CORNER 12° 6° 4'-6" 1 I I BEFORE YOU DIG <br /> ` . ALL POSTS SHALL BE DIAL811 <br /> END 12" 6" 4'-6" � ANCHORED IN CONCRETE <br /> < _ <br /> m m LINE & OTHER 10" 6" 4'-6" / <br /> VERT DATUM: NAVD 88 <br /> CONV TO MLLW = NAVD88+2.03 <br /> 1 DETAIL - TYPICAL SECURITY FENCE HORZ DATUM: NAD 83/91 <br /> F ° C6.1, C6.2, C6.3, C6.5 C6.5 SCALE: NTS IF SHEET IS LESS THAN 22x34 W <br /> a m REDUCE SCALE ACCORDINGLY > <br /> N PROJECT ENGINEER: SCALE: <br /> P� PORT OF EVERETT DWG N0. C6.4 <br /> N. WATSON AS SHOWN <br /> 'C�b pe Idgg� J� DESIGNED BY: DATE: <br /> Port of J. BECKER 05/07/2021 NORTON TERMINAL DEVELOPMENT CIP NO. H <br /> o �'1 T*T T _ <br /> N�{�D u�� 1Tff DRAWN BY: CHECKED BY: 1-8-900-05 <br /> L Lin`L & MTCA 3RD INTERIM ACTION U <br /> 16015th Avenue,Suite 1300 0 06/21/2021 NW ADDED DETAILS svoia o K. EDWARDS, D. YU N. WATSON PROJECT <br /> N P.O. BOX 538 Seattle,Washington 98101 8��, � : SECURITY FENCE DETAILS <br /> y No. MT-NT-2021-02.2 <br /> EVERETT, WA 98206Fax ® OS/07/2021 NW FOR CITY REVIEW "'pIUNSL�,� -y APPROVED BY: <br /> N (425) 259-3164 PROJECT NO.p160012p206)382-0500 NO. DATE BY REVISION NO. DATE BY REVISION b (1 OF 3) SHEET NO. 91 OF 149 O <br />
The URL can be used to link to this page
Your browser does not support the video tag.